CONVERTER MOD DC/DC 40V 100W
ECAD Model:
Datasheet:
VI-B3K-MW-S

Quick Request Quote

Please send RFQ , We will respond immediately.

Part Number
Quantity
Company
E-mail
Phone
Comments
Specifications
Vicor Corporation VI-B3K-MW-S technical specifications, attributes, parameters and parts with similar specifications to Vicor Corporation VI-B3K-MW-S.
  • Mount
    Through Hole
  • Mounting Type
    Through Hole
  • Package / Case
    Full Brick
  • Operating Temperature
    -55°C~85°C
  • Packaging
    Bulk
  • Series
    VI-200™ (100W)
  • Published
    2013
  • Size / Dimension
    4.60Lx1.80W x 0.52 H 116.8mmx45.7mmx13.2mm
  • Feature
    OCP, OTP, OVP, SCP
  • Part Status
    Active
  • Moisture Sensitivity Level (MSL)
    Not Applicable
  • Applications
    ITE (Commercial)
  • Power (Watts)
    100W
  • Additional Feature
    REMOTE SHUTDOWN
  • Subcategory
    Power Supply Modules
  • Max Power Dissipation
    100W
  • Number of Outputs
    1
  • Approval Agency
    TUV, UL
  • Efficiency
    90%
  • Voltage - Isolation
    3kV
  • Voltage - Input (Max)
    60V
  • Output Voltage
    40V
  • Max Output Current
    2.5A
  • Voltage - Output 1
    40V
  • Voltage - Input (Min)
    42V
  • Input Voltage-Nom
    48V
  • Height
    13.208mm
  • Width
    45.7mm
  • RoHS Status
    Non-RoHS Compliant
Description
Images are for reference only.See Product Specifications for product details.If you are interested to buy Vicor VI-B3K-MW-S.
Product Comparison
The three parts on the right have similar specifications to VI-B3K-MW-S.
  • Image
    Part Number
    Manufacturer
    Mount
    Mounting Type
    Package / Case
    Operating Temperature
    Packaging
    Series
    Published
    Size / Dimension
    Feature
    Part Status
    Moisture Sensitivity Level (MSL)
    Applications
    Power (Watts)
    Additional Feature
    Subcategory
    Max Power Dissipation
    Number of Outputs
    Approval Agency
    Efficiency
    Voltage - Isolation
    Voltage - Input (Max)
    Output Voltage
    Max Output Current
    Voltage - Output 1
    Voltage - Input (Min)
    Input Voltage-Nom
    Height
    Width
    RoHS Status
    Max Operating Temperature
    Min Operating Temperature
    Current - Output (Max)
    Min Input Voltage
    Max Input Voltage
    Length
    Factory Lead Time
    View Compare
  • VI-B3K-MW-S
    VI-B3K-MW-S
    Through Hole
    Through Hole
    Full Brick
    -55°C~85°C
    Bulk
    VI-200™ (100W)
    2013
    4.60Lx1.80W x 0.52 H 116.8mmx45.7mmx13.2mm
    OCP, OTP, OVP, SCP
    Active
    Not Applicable
    ITE (Commercial)
    100W
    REMOTE SHUTDOWN
    Power Supply Modules
    100W
    1
    TUV, UL
    90%
    3kV
    60V
    40V
    2.5A
    40V
    42V
    48V
    13.208mm
    45.7mm
    Non-RoHS Compliant
    -
    -
    -
    -
    -
    -
    -
    -
  • VI-B00-IY-F1
    Through Hole
    Through Hole
    Full Brick
    -40°C~85°C
    Bulk
    VI-200™ (50W)
    2013
    4.60Lx1.86W x 0.79 H 116.8mmx47.2mmx20.1mm
    OCP, OTP, OVP, SCP
    Active
    Not Applicable
    ITE (Commercial)
    50W
    -
    -
    50W
    1
    -
    90%
    3kV
    20V
    -
    10A
    5V
    10V
    -
    20.066mm
    47.244mm
    Non-RoHS Compliant
    85°C
    -40°C
    10A
    10V
    20V
    116.84mm
    -
  • VI-B01-04
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Active
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    16 Weeks
  • VI-B00-MY-F4
    Through Hole
    Through Hole
    Full Brick
    -55°C~85°C
    Bulk
    VI-200™ (50W)
    2013
    4.60Lx1.86W x 1.05 H 116.8mmx47.2mmx26.7mm
    OCP, OTP, OVP, SCP
    Active
    Not Applicable
    ITE (Commercial)
    50W
    REMOTE SHUTDOWN
    Power Supply Modules
    50W
    1
    TUV, UL
    90%
    3kV
    20V
    5V
    10A
    5V
    10V
    12V
    26.67mm
    -
    Non-RoHS Compliant
    -
    -
    -
    -
    -
    -
    -
Certification
  • ISO 9001
  • ISO 13485
  • ISO 45001
  • ASA
  • ESD
  • DUNS
  • SMTA
  • ROHS

Latest News

  • 15 September 2023

    Comparing LM741CN and UA741CN Operational Amplifiers

    The two op amps, LM741CN and UA741CN, have similar functional and performance characteristics. They both feature single op amps and similar supply voltages and pinouts. However, they have...
  • 18 September 2023

    TL074CN Symbol, Features and Package

    Ⅰ. Overview of TL074CNⅡ. 3D Model and symbol of TL074CNⅢ. Footprint of TL074CNⅣ. Technical parametersⅤ. Features of TL074CNⅥ. Application of TL074CNⅦ. Package of TL074CNⅧ. How to optimize the...
  • 18 September 2023

    STM32F103C6T6 Microcontroller:Features, Package and Application

    Ⅰ. What is STM32F103C6T6?Ⅱ. 3D Model and pins of STM32F103C6T6Ⅲ. Technical parametersⅣ. Features of STM32F103C6T6Ⅴ. Package of STM32F103C6T6Ⅵ. Application of STM32F103C6T6Ⅶ. Components of the STM32F103C6T6 minimum system boardⅧ....
  • 19 September 2023

    Comparison Between 2N3055 vs TIP3055

    Ⅰ. Overview of 2N3055Ⅱ. Overview of TIP3055Ⅲ. Pin diagram comparisonⅣ. Technical parametersⅤ. Comparison of current amplification factorsⅥ. Package comparisonⅦ. Symbol of 2N3055 and TIP3055Ⅷ. Application scenarios comparisonⅨ. Can...
  • cost

    Help you to save your cost and time.

  • package

    Reliable package for your goods.

  • fast

    Fast Reliable Delivery to save time.

  • service

    Quality premium after-sale service.