HAS 400-S

LEM USA Inc. HAS 400-S

Part Number:
HAS 400-S
Manufacturer:
LEM USA Inc.
Ventron No:
4857905-HAS 400-S
Description:
SENSOR CURRENT HALL 400A AC/DC
ECAD Model:
Datasheet:
HAS 400-S

Quick Request Quote

Please send RFQ , We will respond immediately.

Part Number
Quantity
Company
E-mail
Phone
Comments
Specifications
LEM USA Inc. HAS 400-S technical specifications, attributes, parameters and parts with similar specifications to LEM USA Inc. HAS 400-S.
  • Factory Lead Time
    6 Weeks
  • Mounting Type
    Through Hole
  • Package / Case
    Module
  • Operating Temperature
    -10°C~80°C
  • Packaging
    Tray
  • Series
    HAS
  • Published
    2009
  • Pbfree Code
    yes
  • Part Status
    Active
  • Moisture Sensitivity Level (MSL)
    Not Applicable
  • Voltage - Supply
    ±15V
  • Frequency
    DC~50kHz
  • Output
    Ratiometric, Voltage
  • Current - Supply (Max)
    15mA
  • Body Length or Diameter
    40mm
  • Body Breadth
    20 mm
  • Number of Channels
    1
  • Polarization
    Bidirectional
  • Response Time
    3μs
  • Sensor Type
    Hall Effect, Open Loop
  • Linearity
    ±1%
  • Sensors/Transducers Type
    MAGNETIC FIELD SENSOR,HALL EFFECT
  • Housing
    PLASTIC
  • For Measuring
    AC/DC
  • Current - Sensing
    400A
  • Body Height
    30mm
  • RoHS Status
    RoHS Compliant
Description
HAS 400-S Overview
A Module package is used to protect the current sensors from damage. The devices are protected from damage by the Tray package. It is recommended that these current sensors supply a maximum current of 15mA.

HAS 400-S Features
Moisture Sensitivity Level: Not Applicable
Operating Temperature: -10°C~80°C
1 Channels
Mounting Type: Through Hole
Sensor Type: Hall Effect, Open Loop
Supply Voltage: ±15V
Frequency: DC~50kHz
Sensing Current: 400A
Module Package


HAS 400-S Applications
There are a lot of LEM USA Inc.
HAS 400-S Current Sensors applications.


Power factor correction
Overcurrent protection
DC and AC power monitoring
Closed-L oop DC- and AC-Current Sensor Modules
Leakage Current Sensors
Industrial Monitoring and Control Systems
Overcurrent Detection
Frequency, Voltage, and Solar Inverters
Electrical drives
General purpose inverters
HAS 400-S More Descriptions
SENSOR CURRENT HALL 400A AC/DC
Board Mount Current Sensors
OEMs, CMs ONLY (NO BROKERS)
new, original packaged
Sensor Measuring Range = 900 A / Current Sensor Output Type = ±4 V / Primary Current = 400 A / Current Type = AC / Current Type = DC / Output Voltage Min. V = -4 / Output Voltage Max. V = 4 / Operating Voltage Min. V = -15 / Operating Voltage Max. V = 15 / Frequency Max. kHz = 50 / Accuracy (%) % = 1 / Response Time us = 3 / Linearity (±) % = 1 / Mounting Type = Panel Mount / Series = HAS / Operating Temperature Min. °C = -10 / Operating Temperature Max. °C = 80
Product Comparison
The three parts on the right have similar specifications to HAS 400-S.
  • Image
    Part Number
    Manufacturer
    Factory Lead Time
    Mounting Type
    Package / Case
    Operating Temperature
    Packaging
    Series
    Published
    Pbfree Code
    Part Status
    Moisture Sensitivity Level (MSL)
    Voltage - Supply
    Frequency
    Output
    Current - Supply (Max)
    Body Length or Diameter
    Body Breadth
    Number of Channels
    Polarization
    Response Time
    Sensor Type
    Linearity
    Sensors/Transducers Type
    Housing
    For Measuring
    Current - Sensing
    Body Height
    RoHS Status
    Surface Mount
    Number of Terminations
    Terminal Position
    Terminal Form
    Peak Reflow Temperature (Cel)
    Number of Functions
    Supply Voltage
    Time@Peak Reflow Temperature-Max (s)
    JESD-30 Code
    Analog IC - Other Type
    Neg Supply Voltage-Nom (Vsup)
    View Compare
  • HAS 400-S
    HAS 400-S
    6 Weeks
    Through Hole
    Module
    -10°C~80°C
    Tray
    HAS
    2009
    yes
    Active
    Not Applicable
    ±15V
    DC~50kHz
    Ratiometric, Voltage
    15mA
    40mm
    20 mm
    1
    Bidirectional
    3μs
    Hall Effect, Open Loop
    ±1%
    MAGNETIC FIELD SENSOR,HALL EFFECT
    PLASTIC
    AC/DC
    400A
    30mm
    RoHS Compliant
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
  • HAS 50-P
    8 Weeks
    Through Hole
    Module
    -10°C~80°C
    Tray
    HAS
    -
    -
    Active
    1 (Unlimited)
    ±15V
    DC~50kHz
    Ratiometric, Voltage
    15mA
    -
    -
    1
    Bidirectional
    3μs
    Hall Effect, Open Loop
    ±1%
    -
    -
    AC/DC
    50A
    -
    RoHS Compliant
    NO
    4
    UNSPECIFIED
    PIN/PEG
    NOT SPECIFIED
    1
    15V
    NOT SPECIFIED
    R-PXSS-P4
    ANALOG CIRCUIT
    -15V
  • HAS 400-P
    8 Weeks
    Through Hole
    Module
    -10°C~80°C
    Tray
    HAS
    -
    -
    Active
    1 (Unlimited)
    ±15V
    DC~50kHz
    Ratiometric, Voltage
    15mA
    -
    -
    1
    Bidirectional
    3μs
    Hall Effect, Open Loop
    ±1%
    -
    -
    AC/DC
    400A
    -
    RoHS Compliant
    NO
    4
    UNSPECIFIED
    PIN/PEG
    NOT SPECIFIED
    1
    15V
    NOT SPECIFIED
    R-PXSS-P4
    ANALOG CIRCUIT
    -15V
  • HAS 500-P
    8 Weeks
    Through Hole
    Module
    -10°C~80°C
    Tray
    HAS
    2015
    -
    Active
    1 (Unlimited)
    ±15V
    DC~50kHz
    Ratiometric, Voltage
    15mA
    -
    -
    1
    Bidirectional
    3μs
    Hall Effect, Open Loop
    ±1%
    -
    -
    AC/DC
    500A
    -
    RoHS Compliant
    NO
    4
    UNSPECIFIED
    PIN/PEG
    NOT SPECIFIED
    1
    15V
    NOT SPECIFIED
    R-PXSS-P4
    ANALOG CIRCUIT
    -15V
Certification
  • ISO 9001
  • ISO 13485
  • ISO 45001
  • ASA
  • ESD
  • DUNS
  • SMTA
  • ROHS

Latest News

  • cost

    Help you to save your cost and time.

  • package

    Reliable package for your goods.

  • fast

    Fast Reliable Delivery to save time.

  • service

    Quality premium after-sale service.