LEM USA Inc. HASS 200-S
- Part Number:
- HASS 200-S
- Manufacturer:
- LEM USA Inc.
- Ventron No:
- 4857970-HASS 200-S
- Description:
- SENSOR CURRENT HALL 200A AC/DC
- Datasheet:
- HASS 200-S
LEM USA Inc. HASS 200-S technical specifications, attributes, parameters and parts with similar specifications to LEM USA Inc. HASS 200-S.
- Factory Lead Time6 Weeks
- Mounting TypeThrough Hole
- Package / CaseModule
- Operating Temperature-40°C~85°C
- PackagingTray
- Published2004
- SeriesHASS
- Part StatusActive
- Moisture Sensitivity Level (MSL)Not Applicable
- Voltage - Supply5V
- FrequencyDC~50kHz
- OutputRatiometric, Voltage
- Current - Supply (Max)19mA
- Number of Channels1
- PolarizationBidirectional
- Accuracy±1%
- Response Time3μs
- Sensor TypeHall Effect, Open Loop
- Linearity±0.5%
- For MeasuringAC/DC
- Current - Sensing200A
- RoHS StatusRoHS Compliant
HASS 200-S Overview
The operating temperature range for this particular series, known as HASS, is -40°C to 85°C. The Moisture Sensitivity Level (MSL) is not applicable for this device. The frequency range for this device is DC to 50kHz. The output of this device is ratiometric, meaning that the voltage output is proportional to the input. It has 1 channel and is bidirectional in terms of polarization. The response time for this device is 3μs, making it a fast and efficient option. This device is designed for measuring both AC and DC currents, with a maximum current-sensing capability of 200A. Overall, this device is a reliable and versatile option for various applications.
HASS 200-S Features
Moisture Sensitivity Level: Not Applicable
Operating Temperature: -40°C~85°C
1 Channels
Mounting Type: Through Hole
Sensor Type: Hall Effect, Open Loop
Supply Voltage: 5V
Frequency: DC~50kHz
Sensing Current: 200A
Module Package
HASS 200-S Applications
There are a lot of LEM USA Inc.
HASS 200-S Current Sensors applications.
Overcurrent protection
DC and AC power monitoring
Closed-L oop DC- and AC-Current Sensor Modules
Leakage Current Sensors
Industrial Monitoring and Control Systems
Overcurrent Detection
Frequency, Voltage, and Solar Inverters
Electrical drives
General purpose inverters
AC variable speed drives
The operating temperature range for this particular series, known as HASS, is -40°C to 85°C. The Moisture Sensitivity Level (MSL) is not applicable for this device. The frequency range for this device is DC to 50kHz. The output of this device is ratiometric, meaning that the voltage output is proportional to the input. It has 1 channel and is bidirectional in terms of polarization. The response time for this device is 3μs, making it a fast and efficient option. This device is designed for measuring both AC and DC currents, with a maximum current-sensing capability of 200A. Overall, this device is a reliable and versatile option for various applications.
HASS 200-S Features
Moisture Sensitivity Level: Not Applicable
Operating Temperature: -40°C~85°C
1 Channels
Mounting Type: Through Hole
Sensor Type: Hall Effect, Open Loop
Supply Voltage: 5V
Frequency: DC~50kHz
Sensing Current: 200A
Module Package
HASS 200-S Applications
There are a lot of LEM USA Inc.
HASS 200-S Current Sensors applications.
Overcurrent protection
DC and AC power monitoring
Closed-L oop DC- and AC-Current Sensor Modules
Leakage Current Sensors
Industrial Monitoring and Control Systems
Overcurrent Detection
Frequency, Voltage, and Solar Inverters
Electrical drives
General purpose inverters
AC variable speed drives
HASS 200-S More Descriptions
SENSOR CURRENT HALL 200A AC/DC
Board Mount Current Sensors
OEMs, CMs ONLY (NO BROKERS)
Sensor Measuring Range = 600 A / Current Sensor Output Type = 2.5V / Primary Current = 200 A / Current Type = AC / Current Type = DC / Output Voltage Max. V = 2.5 / Operating Voltage Max. V = 5 / Frequency Max. kHz = 240 / Accuracy (%) % = 1 / Response Time us = 3.5 / Linearity (±) % = 0.5 / Mounting Type = Panel Mount / Series = HASS / Operating Temperature Min. °C = -40 / Operating Temperature Max. °C = 105
Board Mount Current Sensors
OEMs, CMs ONLY (NO BROKERS)
Sensor Measuring Range = 600 A / Current Sensor Output Type = 2.5V / Primary Current = 200 A / Current Type = AC / Current Type = DC / Output Voltage Max. V = 2.5 / Operating Voltage Max. V = 5 / Frequency Max. kHz = 240 / Accuracy (%) % = 1 / Response Time us = 3.5 / Linearity (±) % = 0.5 / Mounting Type = Panel Mount / Series = HASS / Operating Temperature Min. °C = -40 / Operating Temperature Max. °C = 105
The three parts on the right have similar specifications to HASS 200-S.
-
ImagePart NumberManufacturerFactory Lead TimeMounting TypePackage / CaseOperating TemperaturePackagingPublishedSeriesPart StatusMoisture Sensitivity Level (MSL)Voltage - SupplyFrequencyOutputCurrent - Supply (Max)Number of ChannelsPolarizationAccuracyResponse TimeSensor TypeLinearityFor MeasuringCurrent - SensingRoHS StatusView Compare
-
HASS 200-S6 WeeksThrough HoleModule-40°C~85°CTray2004HASSActiveNot Applicable5VDC~50kHzRatiometric, Voltage19mA1Bidirectional±1%3μsHall Effect, Open Loop±0.5%AC/DC200ARoHS Compliant-
-
6 WeeksThrough HoleModule-40°C~85°CTray2011HASSActiveNot Applicable5VDC~50kHzRatiometric, Voltage19mA1Bidirectional±1%3μsHall Effect, Open Loop±0.5%AC/DC600ARoHS Compliant
-
6 WeeksThrough HoleModule-40°C~85°CTray2012HASSActiveNot Applicable5VDC~50kHzRatiometric, Voltage19mA1Bidirectional±1%3μsHall Effect, Open Loop±0.5%AC/DC500ARoHS Compliant
-
6 WeeksThrough HoleModule-40°C~85°CTray2011HASSActiveNot Applicable5VDC~50kHzRatiometric, Voltage19mA1Bidirectional±1%3μsHall Effect, Open Loop±0.5%AC/DC400ARoHS Compliant
Popular Search Part Number
Related Keywords
Search Tags
- MLX91220KDC-ABR-025-RE
- MLX91220KDF-ABF-075-RE
- MLX91220KDC-ABR-050-RE
- MLX91220KDC-ABF-050-RE
- MLX91220KDC-ABR-025-SP
- MLX91220KDC-ABF-025-SP
- AIMH040-600A-420
- GO 10 SMS/SP3
- GO 10 SME KIT
- MLX91220KDF-ABF-050-RE
- MLX91220KDF-ABF-075-SP
- MLX91220KDC-ABR-030-RE
- MLX91220KDC-ABR-050-SP
- CSNX1000M-101
- MLX91220KDF-ABF-025-RE
Latest News
-
02 April 2024
TPS54202DDCR Alternatives, Characteristics, Layout and TPS54202DDCR vs TPS54202DDCT
Ⅰ. What is TPS54202DDCR?Ⅱ. Functional modes of TPS54202DDCRⅢ. Characteristics of TPS54202DDCRⅣ. How to reduce the noise of TPS54202DDCR?Ⅴ. Comparison between TPS54202DDCR and TPS54202DDCTⅥ. Layout of TPS54202DDCRⅦ. How to... -
02 April 2024
L6599D Working Principle, Application, Common Faults and Solutions
Ⅰ. Overview of L6599DⅡ. Line sensing function of L6599DⅢ. Working principle of L6599DⅣ. Application of L6599DⅤ. Application circuit of L6599DⅥ. Common faults and solutions of L6599DⅦ. Typical electrical... -
03 April 2024
ADUM1201BRZ-RL7 Alternatives, Specifications, Application and More
Ⅰ. Overview of ADUM1201BRZ-RL7Ⅱ. Specifications of ADUM1201BRZ-RL7Ⅲ. Propagation delay-related parametersⅣ. Application of ADUM1201BRZ-RL7Ⅴ. How to evaluate the performance of ADUM1201BRZ-RL7?Ⅵ. Functional block diagram of ADUM1201BRZ-RL7Ⅶ. PCB layout of... -
03 April 2024
SG3525 PWM IC Characteristics, Internal Structure, Working Principle and SG3525 vs SG3524
Ⅰ. Description of SG3525Ⅱ. Characteristics of SG3525Ⅲ. Internal structure and working principle of SG3525Ⅳ. Representative block diagram of SG3525Ⅴ. Application circuit of SG3525Ⅵ. How to adjust the frequency...
Help you to save your cost and time.
Reliable package for your goods.
Fast Reliable Delivery to save time.
Quality premium after-sale service.