Schaffner EMC Inc. FN286-6-06
- Part Number:
- FN286-6-06
- Manufacturer:
- Schaffner EMC Inc.
- Ventron No:
- 2124121-FN286-6-06
- Description:
- PWR ENT MOD RCPT IEC320-C14 PNL
- Datasheet:
- FN286-6-06
Schaffner EMC Inc. FN286-6-06 technical specifications, attributes, parameters and parts with similar specifications to Schaffner EMC Inc. FN286-6-06.
- Factory Lead Time10 Weeks
- MountPanel, Snap in
- Mounting TypePanel Mount, Snap-In
- Package / CaseModule
- PackagingTray
- SeriesFN 280
- Published2000
- Pbfree Codeyes
- Part StatusActive
- Moisture Sensitivity Level (MSL)1 (Unlimited)
- TerminationQuick Connect - 0.250 (6.3mm)
- ECCN CodeEAR99
- Connector TypeReceptacle, Male Blades - Module
- Number of Positions3
- Max Operating Temperature85°C
- Min Operating Temperature-25°C
- GenderMale
- Additional FeatureSTANDARDS: CSA, UL
- Capacitance220nF
- Voltage - Rated DC250V
- MIL ConformanceNO
- DIN ConformanceNO
- IEC ConformanceYES
- OptionGENERAL PURPOSE
- Total Number of Contacts3
- OrientationStraight
- Ingress ProtectionIP40
- Depth65.3mm
- Current Rating6A
- Frequency400Hz
- Voltage - Rated AC250V
- Approval AgencyCQC, CSA, ENEC, UL
- Panel Cutout DimensionsRectangular - 29.00mm x 61.50mm
- Max Voltage Rating (AC)250V
- Max Current Rating6A
- Connector StyleIEC 320-C14
- Number of Ports1
- Current6A
- Voltage - UL250VAC
- Filter TypeFiltered (EMI, RFI) - Commercial
- Accomodates a FuseYes (Fuse Not Included)
- FuseYes
- Fuse Holder, DrawerFuse Holder, Twin Fused
- Switch FeaturesSwitch On-Off
- Height65mm
- Length32mm
- Width32mm
- Panel Thickness0.031 ~ 0.118 0.79mm ~ 3.00mm
- Material Flammability RatingUL94 V-2
- REACH SVHCNo SVHC
- Radiation HardeningNo
- RoHS StatusRoHS Compliant
- Flammability RatingUL94 V-2
FN286-6-06 Overview
This product is manufactured by Schaffner EMC Inc. and belongs to the category of Power Entry Connectors - Inlets, Outlets, Modules. The images we provide are for reference only, for detailed product information please see specification sheet FN286-6-06 or the datasheet in PDF format. As a professional electronic components distributor, Ventron has five million electronic components available. Additionally, we have over 500,000 electronic components in stock ready for immediate shipment. If you have requirements, you can send us a quotation form to get the price of FN286-6-06. We attach great importance to our customers' purchasing experience and are willing to establish a long-term cooperative relationship with you. If you have any questions or requirements, please feel free to contact us.
This product is manufactured by Schaffner EMC Inc. and belongs to the category of Power Entry Connectors - Inlets, Outlets, Modules. The images we provide are for reference only, for detailed product information please see specification sheet FN286-6-06 or the datasheet in PDF format. As a professional electronic components distributor, Ventron has five million electronic components available. Additionally, we have over 500,000 electronic components in stock ready for immediate shipment. If you have requirements, you can send us a quotation form to get the price of FN286-6-06. We attach great importance to our customers' purchasing experience and are willing to establish a long-term cooperative relationship with you. If you have any questions or requirements, please feel free to contact us.
FN286-6-06 More Descriptions
Power Entry Module, 1-Ph IEC Inlet, 6 A, Fuse Holder, Fast-on, FN280 Series | Schaffner FN286-6-06
FILTER, 6A, 2 FUSE, SNAP IN; Product Range: FN 280 Series; Gender: Plug; Voltage Rating: 250VAC; Current Rating: 6A; Connector Mounting: Panel Mount; Contact Termination Type: Solder; SVHC: No SVHC (15-Jan-2019); Approval Bodies: CSA, SEMKO, SEV, UL, VDE; Contact Termination: Solder; External Depth: 43.6mm; External Length / Height: 65mm; External Width: 32mm; Voltage Rating VAC: 250V
Power Entry Module; Connector Type:Iec C14; Current Rating:6A; Voltage Rating:250Vac; Fuse Holder:2-Pole Fuse Holder; Fuse Size Held:5Mm X 20Mm; Connector Terminals:Quick Connect; Connector Mounting:Snap-In, Flange Mount; Gender:Plugrohs Compliant: Yes |Schaffner FN286-6-06
FILTER, 6A, 2 FUSE, SNAP IN; Product Range: FN 280 Series; Gender: Plug; Voltage Rating: 250VAC; Current Rating: 6A; Connector Mounting: Panel Mount; Contact Termination Type: Solder; SVHC: No SVHC (15-Jan-2019); Approval Bodies: CSA, SEMKO, SEV, UL, VDE; Contact Termination: Solder; External Depth: 43.6mm; External Length / Height: 65mm; External Width: 32mm; Voltage Rating VAC: 250V
Power Entry Module; Connector Type:Iec C14; Current Rating:6A; Voltage Rating:250Vac; Fuse Holder:2-Pole Fuse Holder; Fuse Size Held:5Mm X 20Mm; Connector Terminals:Quick Connect; Connector Mounting:Snap-In, Flange Mount; Gender:Plugrohs Compliant: Yes |Schaffner FN286-6-06
The three parts on the right have similar specifications to FN286-6-06.
-
ImagePart NumberManufacturerFactory Lead TimeMountMounting TypePackage / CasePackagingSeriesPublishedPbfree CodePart StatusMoisture Sensitivity Level (MSL)TerminationECCN CodeConnector TypeNumber of PositionsMax Operating TemperatureMin Operating TemperatureGenderAdditional FeatureCapacitanceVoltage - Rated DCMIL ConformanceDIN ConformanceIEC ConformanceOptionTotal Number of ContactsOrientationIngress ProtectionDepthCurrent RatingFrequencyVoltage - Rated ACApproval AgencyPanel Cutout DimensionsMax Voltage Rating (AC)Max Current RatingConnector StyleNumber of PortsCurrentVoltage - ULFilter TypeAccomodates a FuseFuseFuse Holder, DrawerSwitch FeaturesHeightLengthWidthPanel ThicknessMaterial Flammability RatingREACH SVHCRadiation HardeningRoHS StatusFlammability RatingFeatureContact MaterialContact Finish - MatingCoupling TypeView Compare
-
FN286-6-0610 WeeksPanel, Snap inPanel Mount, Snap-InModuleTrayFN 2802000yesActive1 (Unlimited)Quick Connect - 0.250 (6.3mm)EAR99Receptacle, Male Blades - Module385°C-25°CMaleSTANDARDS: CSA, UL220nF250VNONOYESGENERAL PURPOSE3StraightIP4065.3mm6A400Hz250VCQC, CSA, ENEC, ULRectangular - 29.00mm x 61.50mm250V6AIEC 320-C1416A250VACFiltered (EMI, RFI) - CommercialYes (Fuse Not Included)YesFuse Holder, Twin FusedSwitch On-Off65mm32mm32mm0.031 ~ 0.118 0.79mm ~ 3.00mmUL94 V-2No SVHCNoRoHS CompliantUL94 V-2-----
-
10 WeeksPanel, Snap inPanel Mount, Snap-InModuleTrayFN 2802009yesActive1 (Unlimited)Quick Connect - 0.250 (6.3mm)EAR99Receptacle, Male Blades - Module385°C-25°CMaleSTANDARDS: CSA, UL220nF250VNONOYESGENERAL PURPOSE3StraightIP4065.3mm2A400Hz250VCQC, CSA, ENEC, ULRectangular - 29.00mm x 61.50mm250V2AIEC 320-C1412A250VACFiltered (EMI, RFI) - Commercial, MedicalYes (Fuse Not Included)YesFuse Holder, Twin FusedSwitch On-Off65mm32mm32mm0.031 ~ 0.118 0.79mm ~ 3.00mmUL94 V-2No SVHCNoRoHS CompliantUL94 V-2Bleed Resistor---
-
10 WeeksPanel, Snap inPanel Mount, Snap-InModuleTrayFN 2802009yesActive1 (Unlimited)Quick Connect - 0.250 (6.3mm)EAR99Receptacle, Male Blades - Module385°C-25°CMaleSTANDARDS: CSA, UL220nF250VNONOYESGENERAL PURPOSE3StraightIP4065.3mm4A400Hz250VCQC, CSA, ENEC, ULRectangular - 29.00mm x 61.50mm250V4AIEC 320-C1414A250VACFiltered (EMI, RFI) - CommercialYes (Fuse Not Included)YesFuse HolderSwitch On-Off65mm32mm32mm0.031 ~ 0.118 0.79mm ~ 3.00mmUL94 V-2No SVHCNoRoHS CompliantUL94 V-2----
-
10 WeeksFlanges, Panel, ScrewPanel Mount, FlangeModuleTrayFN 2802013yesActive1 (Unlimited)Quick Connect - 0.250 (6.3mm)EAR99Receptacle, Male Blades - Module385°C-25°CMaleSTANDARDS: CSA, UL-250VNONOYESGENERAL PURPOSE3StraightIP4048.6mm1A400Hz250VCQC, CSA, ENEC, ULRectangular - 29.00mm x 60.00mm250V1AIEC 320-C1411A250VACFiltered (EMI, RFI) - CommercialYes (Fuse Not Included)YesFuse HolderSwitch On-Off65mm-50mm-UL94 V-2--RoHS CompliantUL94 V-2Earth Line Choke, Front or Rear Side MountNOT SPECIFIEDNOT SPECIFIEDSNAP
Popular Search Part Number
Related Keywords
Search Tags
Latest News
-
17 January 2024
DS18B20 Digital Temperature Sensor Structure, Features, Applications and More
Ⅰ. What is DS18B20?Ⅱ. Internal structure of DS18B20Ⅲ. Features of DS18B20 sensorⅣ. How does DS18B20 work?Ⅴ. Symbol, footprint and pin configuration of DS18B20Ⅵ. Driving principle of DS18B20Ⅶ. Where... -
18 January 2024
What is the BTN8982TA Bridge and How Does it Work?
Ⅰ. Introduction to BTN8982TAⅡ. Block diagram of BTN8982TAⅢ. Specifications of BTN8982TAⅣ. Working principle of BTN8982TAⅤ. BTN8982TA symbol, footprint and pin configurationⅥ. Features of BTN8982TAⅦ. Application fields of BTN8982TABTN8982TA... -
18 January 2024
TPS51200DRCR: Advanced Regulator Solution for DDR Termination
Ⅰ. Overview of TPS51200DRCRⅡ. Technical parameters of TPS51200DRCRⅢ. What are the advantages of TPS51200DRCR?Ⅳ. Absolute maximum ratings of TPS51200DRCRⅤ. How to use TPS51200DRCR?Ⅵ. Where is TPS51200DRCR used?Ⅶ. TPS51200DRCR... -
19 January 2024
TXB0104PWR Alternatives, Package, Specifications and Applications
Ⅰ. TXB0104PWR overviewⅡ. Operating principle of TXB0104PWRⅢ. Package of TXB0104PWRⅣ. Specifications of TXB0104PWRⅤ. How to use TXB0104PWR?Ⅵ. What are the applications of TXB0104PWR?Ⅶ. How does TXB0104PWR realize automatic...
Help you to save your cost and time.
Reliable package for your goods.
Fast Reliable Delivery to save time.
Quality premium after-sale service.