CHS-MSS

TDK Corporation CHS-MSS

Part Number:
CHS-MSS
Manufacturer:
TDK Corporation
Ventron No:
4422612-CHS-MSS
Description:
SENSOR HUMIDITY 5V ANALOG 5% MOD
ECAD Model:
Datasheet:
CHS-MSS

Quick Request Quote

Please send RFQ , We will respond immediately.

Part Number
Quantity
Company
E-mail
Phone
Comments
Specifications
TDK Corporation CHS-MSS technical specifications, attributes, parameters and parts with similar specifications to TDK Corporation CHS-MSS.
  • Lifecycle Status
    PRODUCTION (Last Updated: 2 months ago)
  • Factory Lead Time
    8 Weeks
  • Mount
    Through Hole
  • Mounting Type
    Through Hole
  • Package / Case
    Housed Sensor
  • Number of Pins
    3
  • Operating Temperature
    0°C~50°C
  • Packaging
    Bulk
  • Series
    CHS
  • Published
    2001
  • Part Status
    Active
  • Moisture Sensitivity Level (MSL)
    1 (Unlimited)
  • Number of Terminations
    3
  • Voltage - Supply
    4.75V~5.25V
  • Terminal Position
    SINGLE
  • Number of Functions
    1
  • Supply Voltage
    5V
  • Output
    500mV @ 50%RH
  • Qualification Status
    Not Qualified
  • Output Type
    Analog Voltage
  • Operating Supply Voltage
    7V
  • Analog IC - Other Type
    ANALOG CIRCUIT
  • Operating Supply Current
    600μA
  • Accuracy
    ±5% RH
  • Response Time
    60s
  • Sensor Type
    Humidity
  • Sensing Method
    Resistive
  • Max Supply Voltage (DC)
    5.25V
  • Min Supply Voltage (DC)
    4.75V
  • Humidity Range
    20 ~ 85% RH
  • REACH SVHC
    No SVHC
  • RoHS Status
    ROHS3 Compliant
  • Lead Free
    Lead Free
Description
Images are for reference only.See Product Specifications for product details.If you are interested to buy TDK Corporation CHS-MSS.
CHS-MSS More Descriptions
Humidity Sensors, Product Type=Assembly, Nominal Accuracy=±5%
TDK CHS-MSS SENSOR, HUMIDITY, 20-85% RH RANGE
HUMIDITY SENSOR, 0 TO 50DEG C, 5.25V;
Product Comparison
The three parts on the right have similar specifications to CHS-MSS.
  • Image
    Part Number
    Manufacturer
    Lifecycle Status
    Factory Lead Time
    Mount
    Mounting Type
    Package / Case
    Number of Pins
    Operating Temperature
    Packaging
    Series
    Published
    Part Status
    Moisture Sensitivity Level (MSL)
    Number of Terminations
    Voltage - Supply
    Terminal Position
    Number of Functions
    Supply Voltage
    Output
    Qualification Status
    Output Type
    Operating Supply Voltage
    Analog IC - Other Type
    Operating Supply Current
    Accuracy
    Response Time
    Sensor Type
    Sensing Method
    Max Supply Voltage (DC)
    Min Supply Voltage (DC)
    Humidity Range
    REACH SVHC
    RoHS Status
    Lead Free
    JESD-609 Code
    Terminal Finish
    Radiation Hardening
    Max Operating Temperature
    Min Operating Temperature
    View Compare
  • CHS-MSS
    CHS-MSS
    PRODUCTION (Last Updated: 2 months ago)
    8 Weeks
    Through Hole
    Through Hole
    Housed Sensor
    3
    0°C~50°C
    Bulk
    CHS
    2001
    Active
    1 (Unlimited)
    3
    4.75V~5.25V
    SINGLE
    1
    5V
    500mV @ 50%RH
    Not Qualified
    Analog Voltage
    7V
    ANALOG CIRCUIT
    600μA
    ±5% RH
    60s
    Humidity
    Resistive
    5.25V
    4.75V
    20 ~ 85% RH
    No SVHC
    ROHS3 Compliant
    Lead Free
    -
    -
    -
    -
    -
    -
  • CHS-UPS
    PRODUCTION (Last Updated: 2 months ago)
    8 Weeks
    Through Hole
    Through Hole
    Housed Sensor
    3
    0°C~50°C
    Bulk
    CHS
    2001
    Active
    1 (Unlimited)
    3
    4.75V~5.25V
    SINGLE
    1
    5V
    500mV @ 50%RH
    Not Qualified
    Analog Voltage
    5V
    ANALOG CIRCUIT
    600μA
    ±3% RH
    60s
    Humidity
    -
    -
    -
    5 ~ 95% RH
    -
    ROHS3 Compliant
    Lead Free
    e0
    TIN LEAD
    -
    -
    -
  • CHS-UGS
    PRODUCTION (Last Updated: 2 months ago)
    8 Weeks
    Through Hole
    Through Hole
    Housed Sensor
    3
    0°C~50°C
    Bulk
    CHS
    2001
    Active
    1 (Unlimited)
    3
    4.75V~5.25V
    SINGLE
    1
    5V
    500mV @ 50%RH
    -
    Analog Voltage
    5V
    ANALOG CIRCUIT
    600μA
    ±5% RH
    60s
    Humidity
    -
    -
    -
    5 ~ 95% RH
    -
    ROHS3 Compliant
    Lead Free
    e0
    TIN LEAD
    No
    -
    -
  • CHS-CSC-20
    PRODUCTION (NOT RECOMMENDED FOR NEW DESIGN) (Last Updated: 2 months ago)
    12 Weeks
    -
    User Defined
    Sensor on Exposed Board
    3
    15°C~35°C
    Tray
    CHS
    2007
    Active
    1 (Unlimited)
    -
    4.75V~5.25V
    -
    -
    -
    1.6V @ 70%RH
    -
    Analog Voltage
    -
    -
    -
    ±7% RH
    60s
    Humidity, Temperature
    -
    -
    -
    10 ~ 90% RH
    -
    ROHS3 Compliant
    -
    -
    -
    -
    35°C
    15°C
Certification
  • ISO 9001
  • ISO 13485
  • ISO 45001
  • ASA
  • ESD
  • DUNS
  • SMTA
  • ROHS

Latest News

  • cost

    Help you to save your cost and time.

  • package

    Reliable package for your goods.

  • fast

    Fast Reliable Delivery to save time.

  • service