Honeywell Sensing and Productivity Solutions SS449A-L
- Part Number:
- SS449A-L
- Manufacturer:
- Honeywell Sensing and Productivity Solutions
- Ventron No:
- 8922319-SS449A-L
- Description:
- TO-92-3
- Datasheet:
- SS449A-L
Honeywell Sensing and Productivity Solutions SS449A-L technical specifications, attributes, parameters and parts with similar specifications to Honeywell Sensing and Productivity Solutions SS449A-L.
- Factory Lead Time25 Weeks
- Package / CaseTO-92-3
- Published2012
- Part StatusActive
- Max Operating Temperature150°C
- Min Operating Temperature-40°C
- Max Output Current20mA
- Operating Supply Voltage30V
- Leakage Current10μA
- Nominal Supply Current10mA
- Output Current20mA
- RoHS StatusRoHS Compliant
SS449A-L Overview
The magnetic switches are put into TO-92-3 packages for safety protection. These switches can output 20mA as the maximum current when they work. In general, the current output by the switches should be 20mA. The maximum operating temperature for the magnetic switches can be set to 150°C. However, the operating temperature should not be less than -40°C in order for this magnetic switch to work. The magnetic switches could supply 30V voltage when it operates. Nominally, it can supply 10mA current when it works.
SS449A-L Applications
There are a lot of Honeywell Sensing and Productivity Solutions
SS449A-L Magnetic Switches applications.
Speed and RPM (revolutions per minute) sensing
Tachometer
Counter pickup
Flow-rate sensing
Brushless DC (direct current) motor commutation
Motor and fan control
Robotics control
Electric window lift
Convertible roof position
Motor assemblies
The magnetic switches are put into TO-92-3 packages for safety protection. These switches can output 20mA as the maximum current when they work. In general, the current output by the switches should be 20mA. The maximum operating temperature for the magnetic switches can be set to 150°C. However, the operating temperature should not be less than -40°C in order for this magnetic switch to work. The magnetic switches could supply 30V voltage when it operates. Nominally, it can supply 10mA current when it works.
SS449A-L Applications
There are a lot of Honeywell Sensing and Productivity Solutions
SS449A-L Magnetic Switches applications.
Speed and RPM (revolutions per minute) sensing
Tachometer
Counter pickup
Flow-rate sensing
Brushless DC (direct current) motor commutation
Motor and fan control
Robotics control
Electric window lift
Convertible roof position
Motor assemblies
SS449A-L More Descriptions
Board Mount Hall Effect / Magnetic Sensors COMM SOLID STATE/MAG
Speed & Position,Magnetic Sensors,Unipolar
Honeywell Commercial Solid State/Magnet
SS41 Series Bipolar Hall Effect sensors respond to alternating North and South poles. A built-in regulator provides stable operation over 4.5 Vdc to 24 Vdc supply voltage range, and internal circuitry prevents sensor damage in case the supply voltage polarity is accidentally reversed. The SS41 Series Bipolar Hall-effect sensors are small, versatile digital Hall-effect devices that are operated by the magnetic field from a permanent magnet or an electromagnet. The open-collector sinking output voltage is easily interfaced with a wide variety of electronic circuits. NOTE: These digital Hall sensors have an operating temperature range of -40 °C to 125 °C [-40 °F to 257 °F], appropriate for commercial, consumer, and industrial environments.
Speed & Position,Magnetic Sensors,Unipolar
Honeywell Commercial Solid State/Magnet
SS41 Series Bipolar Hall Effect sensors respond to alternating North and South poles. A built-in regulator provides stable operation over 4.5 Vdc to 24 Vdc supply voltage range, and internal circuitry prevents sensor damage in case the supply voltage polarity is accidentally reversed. The SS41 Series Bipolar Hall-effect sensors are small, versatile digital Hall-effect devices that are operated by the magnetic field from a permanent magnet or an electromagnet. The open-collector sinking output voltage is easily interfaced with a wide variety of electronic circuits. NOTE: These digital Hall sensors have an operating temperature range of -40 °C to 125 °C [-40 °F to 257 °F], appropriate for commercial, consumer, and industrial environments.
The three parts on the right have similar specifications to SS449A-L.
-
ImagePart NumberManufacturerFactory Lead TimePackage / CasePublishedPart StatusMax Operating TemperatureMin Operating TemperatureMax Output CurrentOperating Supply VoltageLeakage CurrentNominal Supply CurrentOutput CurrentRoHS StatusPackagingMax Supply VoltageMin Supply VoltageMounting TypeSupplier Device PackageOperating TemperatureSeriesFeatureMoisture Sensitivity Level (MSL)TechnologyVoltage - SupplyFunctionCurrent - Supply (Max)Output TypeOperating Supply CurrentPolarizationCurrent - Output (Max)Test ConditionSensing RangeView Compare
-
SS449A-L25 WeeksTO-92-32012Active150°C-40°C20mA30V10μA10mA20mARoHS Compliant--------------------
-
27 WeeksTO-92-32002Active150°C-20mA--10mA-RoHS CompliantTape & Reel (TR)------------------
-
11 WeeksTO-92-32012Active150°C-40°C20mA-10μA10mA20mARoHS CompliantTape & Reel (TR)30V3.8V----------------
-
27 Weeks3-SMD, Gull Wing2012Active150°C-40°C20mA12V10μA10mA20mARoHS CompliantTape & Reel (TR)30V3.8VSurface MountRadial Lead-40°C~150°C TASS400Temperature Compensated1 (Unlimited)Hall Effect3.8V~30VUnipolar Switch10mAOpen Collector10mASouth Pole20mA25°C18mT Trip, 7.5mT Release
Popular Search Part Number
Related Keywords
Search Tags
Latest News
-
01 April 2024
M24C16-RMN6TP Structure, Advantages, Package and Other Details
Ⅰ. M24C16-RMN6TP descriptionⅡ. Basic structure and working principle of M24C16-RMN6TPⅢ. Technical parameters of M24C16-RMN6TPⅣ. What are the market competitive advantages of M24C16-RMN6TP?Ⅴ. Package of M24C16-RMN6TPⅥ. Data transmission process... -
02 April 2024
TPS54202DDCR Alternatives, Characteristics, Layout and TPS54202DDCR vs TPS54202DDCT
Ⅰ. What is TPS54202DDCR?Ⅱ. Functional modes of TPS54202DDCRⅢ. Characteristics of TPS54202DDCRⅣ. How to reduce the noise of TPS54202DDCR?Ⅴ. Comparison between TPS54202DDCR and TPS54202DDCTⅥ. Layout of TPS54202DDCRⅦ. How to... -
02 April 2024
L6599D Working Principle, Application, Common Faults and Solutions
Ⅰ. Overview of L6599DⅡ. Line sensing function of L6599DⅢ. Working principle of L6599DⅣ. Application of L6599DⅤ. Application circuit of L6599DⅥ. Common faults and solutions of L6599DⅦ. Typical electrical... -
03 April 2024
ADUM1201BRZ-RL7 Alternatives, Specifications, Application and More
Ⅰ. Overview of ADUM1201BRZ-RL7Ⅱ. Specifications of ADUM1201BRZ-RL7Ⅲ. Propagation delay-related parametersⅣ. Application of ADUM1201BRZ-RL7Ⅴ. How to evaluate the performance of ADUM1201BRZ-RL7?Ⅵ. Functional block diagram of ADUM1201BRZ-RL7Ⅶ. PCB layout of...
Help you to save your cost and time.
Reliable package for your goods.
Fast Reliable Delivery to save time.
Quality premium after-sale service.