Cosel USA, Inc. NAC-20-222-D
- Part Number:
- NAC-20-222-D
- Manufacturer:
- Cosel USA, Inc.
- Ventron No:
- 7198267-NAC-20-222-D
- Description:
- NAC-20-222-D datasheet pdf and Power Line Filter Modules product details from Cosel USA, Inc. stock available at Ventron
- Datasheet:
- NAC-20-222-D
Cosel USA, Inc. NAC-20-222-D technical specifications, attributes, parameters and parts with similar specifications to Cosel USA, Inc. NAC-20-222-D.
- Factory Lead Time6 Weeks
- Mounting TypeDIN Rail
- Operating Temperature-40°C~85°C
- PackagingBox
- Published2006
- SeriesNAC
- Pbfree Codeyes
- Part StatusActive
- Moisture Sensitivity Level (MSL)Not Applicable
- TerminationScrew
- ApplicationsGeneral Purpose
- Capacitance2.2nF
- Voltage - Rated DC250V
- Reach Compliance Codeunknown
- Current Rating20A
- Frequency1MHz
- Termination StyleTerminal Block
- Voltage - Rated AC250V
- Approval AgencycURus, VDE
- Physical DimensionL92.0XB53.0XH41.0 (mm)/L3.622XB2.087XH1.614 (inch)
- ConfigurationSingle Stage
- Leakage Current250μA
- Filter TypeSingle Phase
- High Pot2500 V
- Height41mm
- Length92mm
- RoHS StatusROHS3 Compliant
- Lead FreeLead Free
NAC-20-222-D Overview
The Cosel USA, Inc. Power Line Filter Modules are an essential electronic component within the Power Line Filter Modules category. These modules are designed for optimal performance in power line filtration applications. They have a mounting type of DIN rail, come in a box packaging, and feature a non-applicable moisture sensitivity level. The termination style is terminal block, with a rated voltage of 250V. The components comply with various approvals such as cURLus and VDE. They measure 92.0mm x 53.0mm x 41.0mm (mm) or 3.622" x 2.087" x 1.614" (inch) in physical dimensions. The configuration is single stage, with a height of 41mm. Additionally, they are compliant with the ROHS3 status.
The Cosel USA, Inc. Power Line Filter Modules are an essential electronic component within the Power Line Filter Modules category. These modules are designed for optimal performance in power line filtration applications. They have a mounting type of DIN rail, come in a box packaging, and feature a non-applicable moisture sensitivity level. The termination style is terminal block, with a rated voltage of 250V. The components comply with various approvals such as cURLus and VDE. They measure 92.0mm x 53.0mm x 41.0mm (mm) or 3.622" x 2.087" x 1.614" (inch) in physical dimensions. The configuration is single stage, with a height of 41mm. Additionally, they are compliant with the ROHS3 status.
NAC-20-222-D More Descriptions
Power Line Filter High Attenuation 60Hz 20A 250VAC/250VDC Terminal Block DIN Rail
Power Line Filters AC 1-250 / DC250 20A 0.25mA/ 0.5 mA max
SINGLE PHASE 250VAC Line Filter DIN RAIL
LINE FILTER 250VDC/VAC 20A DIN
Power Line Filters AC 1-250 / DC250 20A 0.25mA/ 0.5 mA max
SINGLE PHASE 250VAC Line Filter DIN RAIL
LINE FILTER 250VDC/VAC 20A DIN
The three parts on the right have similar specifications to NAC-20-222-D.
-
ImagePart NumberManufacturerFactory Lead TimeMounting TypeOperating TemperaturePackagingPublishedSeriesPbfree CodePart StatusMoisture Sensitivity Level (MSL)TerminationApplicationsCapacitanceVoltage - Rated DCReach Compliance CodeCurrent RatingFrequencyTermination StyleVoltage - Rated ACApproval AgencyPhysical DimensionConfigurationLeakage CurrentFilter TypeHigh PotHeightLengthRoHS StatusLead FreeCurrentVoltage - Rated AC (Phase to Ground/Neutral)View Compare
-
NAC-20-222-D6 WeeksDIN Rail-40°C~85°CBox2006NACyesActiveNot ApplicableScrewGeneral Purpose2.2nF250Vunknown20A1MHzTerminal Block250VcURus, VDEL92.0XB53.0XH41.0 (mm)/L3.622XB2.087XH1.614 (inch)Single Stage250μASingle Phase2500 V41mm92mmROHS3 CompliantLead Free---
-
6 WeeksDIN Rail-40°C~85°CBox2016NAC-ActiveNot ApplicableScrewGeneral Purpose2.2nF250V-10A1MHzTerminal Block250VcURus, VDE-Single Stage250μASingle Phase---ROHS3 Compliant-10A250V
-
6 WeeksDIN Rail-40°C~85°CBox2016NAC-ActiveNot ApplicableScrewGeneral Purpose680pF250V-6A1MHzTerminal Block250VcURus, VDE-Single Stage75.5μASingle Phase---ROHS3 Compliant-6A250V
-
6 WeeksDIN Rail-40°C~85°CBox2016NAC-ActiveNot ApplicableScrewGeneral Purpose3.3nF250V-20A1MHzTerminal Block250VcURus, VDE-Single Stage380μASingle Phase---ROHS3 Compliant-20A250V
Popular Search Part Number
Related Keywords
Search Tags
Latest News
-
18 April 2024
ADUM1200ARZ Digital Isolator: Symbol, Functions, Advantages and Application Cases
Ⅰ. Overview of ADUM1200ARZⅡ. Functions and technical standards of ADUM1200ARZⅢ. ADUM1200ARZ symbol, footprint and pin configurationⅣ. Compared with other optocouplers, what are the advantages of ADUM1200ARZ?Ⅴ. Schematic diagram... -
19 April 2024
ADM2587EBRWZ Transceiver Pinout, Features, Application and Use
Ⅰ. Overview of ADM2587EBRWZⅡ. Pin diagram of ADM2587EBRWZⅢ. Main features of ADM2587EBRWZⅣ. Typical applications of ADM2587EBRWZⅤ. Instructions for use of ADM2587EBRWZⅥ. Power isolation and signal isolation of ADM2587EBRWZⅦ.... -
19 April 2024
Introduction to the TPS5430 DC-DC Converter
Ⅰ. TPS5430 descriptionⅡ. Pin arrangement and description of TPS5430Ⅲ. Characteristics of TPS5430Ⅳ. Functional modes of TPS5430Ⅴ. What are the advantages and disadvantages of TPS5430?Ⅵ. Application of TPS5430 in... -
22 April 2024