Schaffner EMC Inc. FN3280H-80-35
- Part Number:
- FN3280H-80-35
- Manufacturer:
- Schaffner EMC Inc.
- Ventron No:
- 7195762-FN3280H-80-35
- Description:
- FN3280H-80-35 datasheet pdf and Power Line Filter Modules product details from Schaffner EMC Inc. stock available at Ventron
- Datasheet:
- FN3280H-80-35
Schaffner EMC Inc. FN3280H-80-35 technical specifications, attributes, parameters and parts with similar specifications to Schaffner EMC Inc. FN3280H-80-35.
- Factory Lead Time10 Weeks
- MountChassis, Chassis Mount, Flanges
- Mounting TypeChassis Mount
- Package / Case300
- Operating Temperature-25°C~100°C
- PackagingTray
- Published2009
- SeriesFN 3280
- Pbfree Codeyes
- Part StatusActive
- Moisture Sensitivity Level (MSL)Not Applicable
- TerminationTerminal Block
- ApplicationsGeneral Purpose
- Voltage - Rated DC520V
- Depth320mm
- Current Rating80A
- Frequency60Hz
- Termination StyleTerminal Block
- Voltage - Rated AC480V
- Approval AgencyCSA, ENEC, UR
- Physical DimensionL230.0XB135.0XH125.0 (mm)/L9.055XB5.315XH4.921 (inch)
- ConfigurationTwo Stage
- Max Voltage Rating (AC)520V
- Max Current Rating80A
- Filter TypeThree Phase (Wye)
- Leakage Current (Max)1mA
- Frequency - OperatingDC~60Hz
- High Pot2250 V
- Voltage - Rated AC (Phase to Ground/Neutral)300V
- Height125mm
- Length230mm
- Width163mm
- Radiation HardeningNo
- REACH SVHCNo SVHC
- RoHS StatusRoHS Compliant
- RatingsIP20
FN3280H-80-35 Overview
Introducing the Schaffner EMC Inc. Power Line Filter Modules, an essential electronic component within the Power Line Filter Modules category. This device features a Terminal Block termination design for general purpose applications. With a current rating of 80A, it operates at a frequency of 60Hz, ensuring optimal performance. Its physical dimensions are 230.0mm x B135.0mm x H125.0mm (mm) / L9.055in x B5.315in x H4.921in. The maximum current rating stands at 80A, with a filter type of Three Phase (Wye). The leakage current is limited to just 1mA, demonstrating exceptional efficiency. The operating frequency is set to DC~60Hz, while its width measures up to 163mm. Experience the difference with Schaffner EMC Inc. Power Line Filter Modules today!
Introducing the Schaffner EMC Inc. Power Line Filter Modules, an essential electronic component within the Power Line Filter Modules category. This device features a Terminal Block termination design for general purpose applications. With a current rating of 80A, it operates at a frequency of 60Hz, ensuring optimal performance. Its physical dimensions are 230.0mm x B135.0mm x H125.0mm (mm) / L9.055in x B5.315in x H4.921in. The maximum current rating stands at 80A, with a filter type of Three Phase (Wye). The leakage current is limited to just 1mA, demonstrating exceptional efficiency. The operating frequency is set to DC~60Hz, while its width measures up to 163mm. Experience the difference with Schaffner EMC Inc. Power Line Filter Modules today!
FN3280H-80-35 More Descriptions
Power Line Filter 3-Phase 0Hz to 60Hz 80A 520VAC Terminal Block Chassis Mount Medical
3-Phase 80 A Chassis Mount Input Filter Safety Terminal Block High Voltage | Schaffner FN3280H-80-35
Power Line Filters 3-PH NEUTRAL 80A FILTER HI-END
Three Phase EMI Filter, 520V, 60HzHz
3 Phase & Neutral Filter 520VAC,
LINE FILTER 480VAC 80A CHASS MNT
Power Line Filter, 80A, 1Ma; Filter Applications:General Purpose; Voltage Rating:520Vac; Current Rating:80A; No. Of Phases:Three Phase; No. Of Stages:2 Stage; Filter Input Terminals:Quick Connect; Product Range:Fn 3280 Series Rohs Compliant: Yes |Schaffner FN3280H-80-35
3-Phase 80 A Chassis Mount Input Filter Safety Terminal Block High Voltage | Schaffner FN3280H-80-35
Power Line Filters 3-PH NEUTRAL 80A FILTER HI-END
Three Phase EMI Filter, 520V, 60HzHz
3 Phase & Neutral Filter 520VAC,
LINE FILTER 480VAC 80A CHASS MNT
Power Line Filter, 80A, 1Ma; Filter Applications:General Purpose; Voltage Rating:520Vac; Current Rating:80A; No. Of Phases:Three Phase; No. Of Stages:2 Stage; Filter Input Terminals:Quick Connect; Product Range:Fn 3280 Series Rohs Compliant: Yes |Schaffner FN3280H-80-35
The three parts on the right have similar specifications to FN3280H-80-35.
-
ImagePart NumberManufacturerFactory Lead TimeMountMounting TypePackage / CaseOperating TemperaturePackagingPublishedSeriesPbfree CodePart StatusMoisture Sensitivity Level (MSL)TerminationApplicationsVoltage - Rated DCDepthCurrent RatingFrequencyTermination StyleVoltage - Rated ACApproval AgencyPhysical DimensionConfigurationMax Voltage Rating (AC)Max Current RatingFilter TypeLeakage Current (Max)Frequency - OperatingHigh PotVoltage - Rated AC (Phase to Ground/Neutral)HeightLengthWidthRadiation HardeningREACH SVHCRoHS StatusRatingsReach Compliance CodeCurrentVoltage - Rated AC (Phase to Phase)View Compare
-
FN3280H-80-3510 WeeksChassis, Chassis Mount, FlangesChassis Mount300-25°C~100°CTray2009FN 3280yesActiveNot ApplicableTerminal BlockGeneral Purpose520V320mm80A60HzTerminal Block480VCSA, ENEC, URL230.0XB135.0XH125.0 (mm)/L9.055XB5.315XH4.921 (inch)Two Stage520V80AThree Phase (Wye)1mADC~60Hz2250 V300V125mm230mm163mmNoNo SVHCRoHS CompliantIP20----
-
1 Weeks-Chassis Mount--40°C~100°C--FN 3288-ActiveNot Applicable-Inverters, Power Drive Systems----Terminal Block530V 305VCE, ENEC, UR-Two Stage--Three Phase (Delta)-DC~60Hz-305V-------compliant25A530V
-
10 Weeks-Chassis Mount--40°C~100°CBox-FN 3288-ActiveNot Applicable-Inverters, Power Drive Systems----Terminal Block760V--Two Stage--Three Phase (Delta)-DC~60Hz-------RoHS Compliant--50A-
-
10 Weeks-Chassis Mount--40°C~100°CBox-FN 3288-ActiveNot Applicable-Inverters, Power Drive Systems----Terminal Block530V 305VCE, ENEC, UR-Two Stage--Three Phase (Delta)-DC~60Hz-305V-----ROHS3 Compliant--40A530V
Popular Search Part Number
Related Keywords
Search Tags
Latest News
-
13 March 2024
74HC595: Efficient 8-Bit Shift Register Chip
Ⅰ. Overview of 74HC595Ⅱ. Pins and functions of 74HC595Ⅲ. Logic diagram of 74HC595Ⅳ. Application of 74HC595Ⅴ. Design of multi-digit LED display based on 74HC595Ⅵ. LED driver circuit design... -
14 March 2024
Comprehensive Understanding of the 78M05 Chip
Ⅰ. Development history of linear voltage regulatorsⅡ. Introduction to 78M05Ⅲ. Pin layout of 78M05Ⅳ. External components of 78M05Ⅴ. Technical key points of 78M05Ⅵ. Internal circuit diagram of 78M05Ⅶ.... -
14 March 2024
What is the NE555 and How Does it Work?
Ⅰ. The birth background of NE555Ⅱ. Introduction to NE555Ⅲ. Design of NE555 timerⅣ. Internal composition of NE555Ⅴ. Operating modes of the NE555Ⅵ. Working principle of NE555Ⅶ. Application of... -
15 March 2024
ULN2003 Alternatives, Characteristics, Working Principle and Application
Ⅰ. ULN2003 overviewⅡ. What are the characteristics of ULN2003?Ⅲ. Pin diagram and functions of ULN2003Ⅳ. Working principle and function of ULN2003Ⅴ. ULN2003 drive circuit diagramⅥ. Where is ULN2003...
Help you to save your cost and time.
Reliable package for your goods.
Fast Reliable Delivery to save time.
Quality premium after-sale service.