U7Y0054

TDK-Lambda Americas Inc. U7Y0054

Part Number:
U7Y0054
Manufacturer:
TDK-Lambda Americas Inc.
Ventron No:
3421603-U7Y0054
Description:
AC/DC CONVERTER 24V 300W
ECAD Model:
Datasheet:
U7Y0054

Quick Request Quote

Please send RFQ , We will respond immediately.

Part Number
Quantity
Company
E-mail
Phone
Comments
Specifications
TDK-Lambda Americas Inc. U7Y0054 technical specifications, attributes, parameters and parts with similar specifications to TDK-Lambda Americas Inc. U7Y0054.
  • Factory Lead Time
    8 Weeks
  • Mount
    Chassis Mount
  • Mounting Type
    Chassis Mount
  • Weight
    709.872059g
  • Operating Temperature
    0°C~60°C With Derating
  • Series
    CFE400M (400W)
  • Published
    2015
  • Size / Dimension
    7.00Lx3.94W x 1.57 H 177.8mmx100.0mmx40.0mm
  • Feature
    Adjustable Output, Remote On/Off, Standby Output, Universal Input
  • Part Status
    Active
  • Moisture Sensitivity Level (MSL)
    1 (Unlimited)
  • Max Operating Temperature
    70°C
  • Min Operating Temperature
    0°C
  • Applications
    ITE (Commercial), Medical
  • Power (Watts)
    300W 400W Forced Air
  • Max Power Dissipation
    300W
  • Number of Outputs
    1
  • Approval Agency
    CE
  • Efficiency
    94%
  • Voltage - Isolation
    4kV
  • Max Output Current
    12.5A
  • Voltage - Output 1
    24V
  • Current - Output (Max)
    12.5A
  • Voltage - Input
    85V~264VAC
  • Height
    39.878mm
  • Length
    177.8mm
  • Width
    100.076mm
  • RoHS Status
    RoHS Compliant
Description
U7Y0054 Overview
This product is manufactured by TDK-Lambda Americas Inc. and belongs to the category of AC DC Converters. The images we provide are for reference only, for detailed product information please see specification sheet U7Y0054 or the datasheet in PDF format. As a professional electronic components distributor, Ventron has five million electronic components available. Additionally, we have over 500,000 electronic components in stock ready for immediate shipment. If you have requirements, you can send us a quotation form to get the price of U7Y0054. We attach great importance to our customers' purchasing experience and are willing to establish a long-term cooperative relationship with you. If you have any questions or requirements, please feel free to contact us.
U7Y0054 More Descriptions
AC-DC Power Supplies, Open frame, Output: 400W, 24V, Option: U channel, 12V/0.25A fan supply
Power Supply, AC-DC, CFE400M245CN1UMLNT ACDC,115230VAC,Output 24V 16.7A,400W
CFE400M-24-5C-N1-UML-NT AC-DC, 115-230VAC, OUTPUT 24V 16.7A
Switching Power Supplies 24V16.7A400W NoCover 12V fan supply
AC/DC Power Supply Single-OUT 24V 12.5A 300W
Power Supply, Ac-Dc, 24V, 12.5A; Power Supply Applications:Ite & Medical; No. Of Outputs:1 Output; Power Rating (Forced Cooling):400W @ 12Cfm; Power Rating (Convection Cooling):300W; Input Voltage Vac:85V Ac To 264V Ac Rohs Compliant: Yes |Tdk-Lambda U7Y0054
Product Comparison
The three parts on the right have similar specifications to U7Y0054.
  • Image
    Part Number
    Manufacturer
    Factory Lead Time
    Mount
    Mounting Type
    Weight
    Operating Temperature
    Series
    Published
    Size / Dimension
    Feature
    Part Status
    Moisture Sensitivity Level (MSL)
    Max Operating Temperature
    Min Operating Temperature
    Applications
    Power (Watts)
    Max Power Dissipation
    Number of Outputs
    Approval Agency
    Efficiency
    Voltage - Isolation
    Max Output Current
    Voltage - Output 1
    Current - Output (Max)
    Voltage - Input
    Height
    Length
    Width
    RoHS Status
    View Compare
  • U7Y0054
    U7Y0054
    8 Weeks
    Chassis Mount
    Chassis Mount
    709.872059g
    0°C~60°C With Derating
    CFE400M (400W)
    2015
    7.00Lx3.94W x 1.57 H 177.8mmx100.0mmx40.0mm
    Adjustable Output, Remote On/Off, Standby Output, Universal Input
    Active
    1 (Unlimited)
    70°C
    0°C
    ITE (Commercial), Medical
    300W 400W Forced Air
    300W
    1
    CE
    94%
    4kV
    12.5A
    24V
    12.5A
    85V~264VAC
    39.878mm
    177.8mm
    100.076mm
    RoHS Compliant
    -
  • U7Y0145
    8 Weeks
    Chassis Mount
    Chassis Mount
    860.011134g
    0°C~70°C With Derating
    CFE400M (400W)
    2015
    7.00Lx3.94W x 2.80 H 177.8mmx100.0mmx71.2mm
    Adjustable Output, Remote On/Off, Standby Output, Universal Input
    Active
    1 (Unlimited)
    70°C
    0°C
    ITE (Commercial), Medical
    400W
    400W
    1
    CE
    94%
    4kV
    8.33A
    48V
    8.33A
    85V~264VAC
    71.12mm
    177.8mm
    100.076mm
    RoHS Compliant
  • U7Y0123
    8 Weeks
    Chassis Mount
    Chassis Mount
    709.872059g
    0°C~60°C With Derating
    CFE400M (400W)
    2015
    7.00Lx3.94W x 2.80 H 177.8mmx100.0mmx71.2mm
    Adjustable Output, Remote On/Off, Standby Output, Universal Input
    Active
    1 (Unlimited)
    70°C
    0°C
    ITE (Commercial), Medical
    300W 400W Forced Air
    300W
    1
    CE
    94%
    4kV
    6.25A
    48V
    6.25A
    85V~264VAC
    71.12mm
    177.8mm
    100.076mm
    RoHS Compliant
  • U7Y0134
    8 Weeks
    Chassis Mount
    Chassis Mount
    709.872059g
    0°C~60°C With Derating
    CFE400M (400W)
    2015
    7.00Lx3.94W x 2.80 H 177.8mmx100.0mmx71.2mm
    Adjustable Output, Remote On/Off, Standby Output, Universal Input
    Active
    1 (Unlimited)
    70°C
    0°C
    ITE (Commercial), Medical
    300W 400W Forced Air
    300W
    1
    CE
    94%
    4kV
    6.25A
    48V
    6.25A
    85V~264VAC
    71.12mm
    177.8mm
    100.076mm
    RoHS Compliant
Certification
  • ISO 9001
  • ISO 13485
  • ISO 45001
  • ASA
  • ESD
  • DUNS
  • SMTA
  • ROHS

Latest News

  • 18 January 2024

    What is the BTN8982TA Bridge and How Does it Work?

    Ⅰ. Introduction to BTN8982TAⅡ. Block diagram of BTN8982TAⅢ. Specifications of BTN8982TAⅣ. Working principle of BTN8982TAⅤ. BTN8982TA symbol, footprint and pin configurationⅥ. Features of BTN8982TAⅦ. Application fields of BTN8982TABTN8982TA...
  • 18 January 2024

    TPS51200DRCR: Advanced Regulator Solution for DDR Termination

    Ⅰ. Overview of TPS51200DRCRⅡ. Technical parameters of TPS51200DRCRⅢ. What are the advantages of TPS51200DRCR?Ⅳ. Absolute maximum ratings of TPS51200DRCRⅤ. How to use TPS51200DRCR?Ⅵ. Where is TPS51200DRCR used?Ⅶ. TPS51200DRCR...
  • 19 January 2024

    TXB0104PWR Alternatives, Package, Specifications and Applications

    Ⅰ. TXB0104PWR overviewⅡ. Operating principle of TXB0104PWRⅢ. Package of TXB0104PWRⅣ. Specifications of TXB0104PWRⅤ. How to use TXB0104PWR?Ⅵ. What are the applications of TXB0104PWR?Ⅶ. How does TXB0104PWR realize automatic...
  • 19 January 2024

    The Best Tutorial for ISO3082DWR

    Ⅰ. Overview of ISO3082DWRⅡ. Technical parameters of ISO3082DWRⅢ. What are the characteristics of ISO3082DWR?Ⅳ. How does ISO3082DWR work?Ⅴ. ISO3082DWR symbol, footprint and pin configurationⅥ. Layout principles of ISO3082DWRⅦ....
  • cost

    Help you to save your cost and time.

  • package

    Reliable package for your goods.

  • fast

    Fast Reliable Delivery to save time.

  • service