Tamura L31S600S05FS
- Part Number:
- L31S600S05FS
- Manufacturer:
- Tamura
- Ventron No:
- 4416171-L31S600S05FS
- Description:
- SENSOR CURRENT HALL 600A AC/DC
- Datasheet:
- L31S600S05FS
Tamura L31S600S05FS technical specifications, attributes, parameters and parts with similar specifications to Tamura L31S600S05FS.
- Factory Lead Time22 Weeks
- MountChassis Mount
- Mounting TypeChassis Mount
- Package / CaseModule, Single Pass Through
- Weight37.000012g
- Operating Temperature-40°C~85°C
- PackagingBulk
- SeriesL31SXXXS05S
- Published2013
- JESD-609 Codee3
- Pbfree Codeyes
- Part StatusActive
- Moisture Sensitivity Level (MSL)1 (Unlimited)
- Terminal FinishTin (Sn)
- Current Rating600A
- FrequencyDC~100kHz
- OutputRatiometric, Voltage
- Current - Supply (Max)15mA
- Output Voltage625mV
- Operating Supply Voltage5V
- Number of Channels1
- PolarizationBidirectional
- Max Supply Current15mA
- Response Time5μs
- Sensor TypeHall Effect, Open Loop
- Linearity±0.5%
- For MeasuringAC/DC
- Height39mm
- Length40.5mm
- Width30.5mm
- RoHS StatusRoHS Compliant
L31S600S05FS Overview
Module, Single Pass Through packages are used for the safety protection of current sensors. In order to protect these current sensors from damage, they are packaged in the Bulk. They should be capable of supplying a maximum current of 15mA. There should be no current greater than 15mA coming from current sensors. Current sensors have been designed to measure 600A current. When they are operated, the current sensors can provide 5V voltage. Sensors that output current should have a voltage of 625mV.
L31S600S05FS Features
Moisture Sensitivity Level: 1 (Unlimited)
Operating Temperature: -40°C~85°C
1 Channels
Mounting Type: Chassis Mount
Sensor Type: Hall Effect, Open Loop
Frequency: DC~100kHz
Module, Single Pass Through Package
L31S600S05FS Applications
There are a lot of Tamura
L31S600S05FS Current Sensors applications.
Industrial Monitoring and Control Systems
Overcurrent Detection
Frequency, Voltage, and Solar Inverters
Electrical drives
General purpose inverters
AC variable speed drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies(UPS)
Switched Mode Power Supplies(SMPS)
Module, Single Pass Through packages are used for the safety protection of current sensors. In order to protect these current sensors from damage, they are packaged in the Bulk. They should be capable of supplying a maximum current of 15mA. There should be no current greater than 15mA coming from current sensors. Current sensors have been designed to measure 600A current. When they are operated, the current sensors can provide 5V voltage. Sensors that output current should have a voltage of 625mV.
L31S600S05FS Features
Moisture Sensitivity Level: 1 (Unlimited)
Operating Temperature: -40°C~85°C
1 Channels
Mounting Type: Chassis Mount
Sensor Type: Hall Effect, Open Loop
Frequency: DC~100kHz
Module, Single Pass Through Package
L31S600S05FS Applications
There are a lot of Tamura
L31S600S05FS Current Sensors applications.
Industrial Monitoring and Control Systems
Overcurrent Detection
Frequency, Voltage, and Solar Inverters
Electrical drives
General purpose inverters
AC variable speed drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies(UPS)
Switched Mode Power Supplies(SMPS)
L31S600S05FS More Descriptions
SENSOR CURRENT HALL 600A AC/DC
耐硫化品 中容量の汎用インバータに最適な電流センサ
HALL EFFECT CURRENT TRANSDUCER
耐硫化品 中容量の汎用インバータに最適な電流センサ
HALL EFFECT CURRENT TRANSDUCER
The three parts on the right have similar specifications to L31S600S05FS.
-
ImagePart NumberManufacturerFactory Lead TimeMountMounting TypePackage / CaseWeightOperating TemperaturePackagingSeriesPublishedJESD-609 CodePbfree CodePart StatusMoisture Sensitivity Level (MSL)Terminal FinishCurrent RatingFrequencyOutputCurrent - Supply (Max)Output VoltageOperating Supply VoltageNumber of ChannelsPolarizationMax Supply CurrentResponse TimeSensor TypeLinearityFor MeasuringHeightLengthWidthRoHS StatusLead FreeView Compare
-
L31S600S05FS22 WeeksChassis MountChassis MountModule, Single Pass Through37.000012g-40°C~85°CBulkL31SXXXS05S2013e3yesActive1 (Unlimited)Tin (Sn)600ADC~100kHzRatiometric, Voltage15mA625mV5V1Bidirectional15mA5μsHall Effect, Open Loop±0.5%AC/DC39mm40.5mm30.5mmRoHS Compliant--
-
22 WeeksChassis MountChassis MountModule, Single Pass Through37.000012g-40°C~85°CBulkL31SXXXS05S2013e3yesActive1 (Unlimited)Tin (Sn)400ADC~100kHzRatiometric, Voltage15mA625mV5V1Bidirectional15mA5μsHall Effect, Open Loop±0.5%AC/DC39mm40.5mm30.5mmRoHS CompliantLead Free
-
22 WeeksChassis MountChassis MountModule, Single Pass Through37.000012g-40°C~85°CBulkL31SXXXS05S2013e3yesActive1 (Unlimited)Tin (Sn)500ADC~100kHzRatiometric, Voltage15mA625mV5V1Bidirectional15mA5μsHall Effect, Open Loop±0.5%AC/DC39mm40.5mm30.5mmRoHS Compliant-
-
22 WeeksChassis MountChassis MountModule, Single Pass Through37.000012g-40°C~85°CBulkL31SXXXS05S2013e3yesActive1 (Unlimited)Tin (Sn)200ADC~100kHzRatiometric, Voltage15mA625mV5V1Bidirectional15mA5μsHall Effect, Open Loop±0.5%AC/DC39mm40.5mm30.5mmRoHS Compliant-
Popular Search Part Number
Related Keywords
Search Tags
- MLX91220KDC-ABR-025-RE
- MLX91220KDF-ABF-075-RE
- MLX91220KDC-ABR-050-RE
- MLX91220KDC-ABF-050-RE
- MLX91220KDC-ABR-025-SP
- MLX91220KDC-ABF-025-SP
- AIMH040-600A-420
- GO 10 SMS/SP3
- GO 10 SME KIT
- MLX91220KDF-ABF-050-RE
- MLX91220KDF-ABF-075-SP
- MLX91220KDC-ABR-030-RE
- MLX91220KDC-ABR-050-SP
- CSNX1000M-101
- MLX91220KDF-ABF-025-RE
Latest News
-
21 February 2024
What is the ADS1118IDGSR and How Does it Work?
Ⅰ. ADS1118IDGSR descriptionⅡ. Specifications of ADS1118IDGSRⅢ. Absolute maximum ratings of ADS1118IDGSRⅣ. How does ADS1118IDGSR work?Ⅴ. Package of ADS1118IDGSRⅥ. What are the characteristics of ADS1118IDGSR?Ⅶ. Typical application of ADS1118IDGSRⅧ.... -
22 February 2024
L293D Motor Driver Characteristics, Technical Parameters, Advantages and Working Principle
Ⅰ. L293D descriptionⅡ. Characteristics of L293DⅢ. Technical parameters of L293DⅣ. Advantages of L293DⅤ. L293D motor driving principleⅥ. Circuit diagram of L293DⅦ. Applications of L293DⅧ. Wiring method of L293D... -
22 February 2024
L7805CV Specifications, Applications and Design Considerations
Ⅰ. Introduction to L7805CVⅡ. Specifications of L7805CVⅢ. L7805CV symbol, footprint and pin configurationⅣ. Applications of L7805CVⅤ. Precautions for using L7805CVⅥ. Absolute maximum ratings of L7805CVⅦ. Design considerations for... -
23 February 2024
ADM2483BRWZ Alternatives, Symbol, Advantages and Disadvantages and Package
Ⅰ. Overview of ADM2483BRWZⅡ. Technical parameters of ADM2483BRWZⅢ. ADM2483BRWZ symbol, footprint and pin configurationⅣ. Circuit description of ADM2483BRWZⅤ. What are the advantages and disadvantages of ADM2483BRWZ?Ⅵ. Dimensions and...
Help you to save your cost and time.
Reliable package for your goods.
Fast Reliable Delivery to save time.
Quality premium after-sale service.