Schaffner EMC Inc. FN3026HL-50-72
- Part Number:
- FN3026HL-50-72
- Manufacturer:
- Schaffner EMC Inc.
- Ventron No:
- 2893660-FN3026HL-50-72
- Description:
- LINE FILTER 50A DIN RAIL
- Datasheet:
- FN3026HL-50-72
Schaffner EMC Inc. FN3026HL-50-72 technical specifications, attributes, parameters and parts with similar specifications to Schaffner EMC Inc. FN3026HL-50-72.
- Factory Lead Time10 Weeks
- MountChassis Mount, DIN Rail, Panel
- Mounting TypeDIN Rail
- Package / Case300
- Operating Temperature-25°C~100°C
- PackagingTray
- Published2009
- SeriesFN 3026
- Pbfree Codeyes
- Part StatusActive
- Moisture Sensitivity Level (MSL)Not Applicable
- TerminationTerminal Block
- Terminal FinishNOT SPECIFIED
- ApplicationsGeneral Purpose
- Depth65mm
- Current Rating50A
- Frequency60Hz
- Termination StyleTerminal Block
- Voltage - Rated AC300V
- Approval AgencyCSA, ENEC, UR
- ConfigurationSingle Stage
- Leakage Current2.5mA
- Max Voltage Rating (AC)520V
- Max Current Rating50A
- Filter TypeThree Phase (Delta)
- Frequency - Operating60Hz
- High Pot2000 V
- Height93.7mm
- Length177mm
- RoHS StatusRoHS Compliant
- RatingsIP00
part No. FN3026HL-50-72 Is this available? : YesShipped from : HK warehouseSame model may have different manufacturers, images only for reference.
FN3026HL-50-72 More Descriptions
Power Line Filter 0Hz to 60Hz 50A 520VAC Wire Lead Chassis Mount/DIN Rail
Compact 3-Phase Low-Leakage Plastic Filter | Schaffner FN3026HL-50-72
3 Phase Plastic Housing Filter 520Vac, Din Rail Mount, 50A Rohs Compliant: Yes |Schaffner FN3026HL-50-72
Power Line Filters ADV EMC/RFI 50A FILTER 3-PHASE
3 Phase Plastic Housing Filter 52
Compact 3-Phase Low-Leakage Plastic Filter | Schaffner FN3026HL-50-72
3 Phase Plastic Housing Filter 520Vac, Din Rail Mount, 50A Rohs Compliant: Yes |Schaffner FN3026HL-50-72
Power Line Filters ADV EMC/RFI 50A FILTER 3-PHASE
3 Phase Plastic Housing Filter 52
The three parts on the right have similar specifications to FN3026HL-50-72.
-
ImagePart NumberManufacturerFactory Lead TimeMountMounting TypePackage / CaseOperating TemperaturePackagingPublishedSeriesPbfree CodePart StatusMoisture Sensitivity Level (MSL)TerminationTerminal FinishApplicationsDepthCurrent RatingFrequencyTermination StyleVoltage - Rated ACApproval AgencyConfigurationLeakage CurrentMax Voltage Rating (AC)Max Current RatingFilter TypeFrequency - OperatingHigh PotHeightLengthRoHS StatusRatingsPower RatingVoltage - Rated DCNumber of ConductorsRadiation HardeningREACH SVHCPhysical DimensionView Compare
-
FN3026HL-50-7210 WeeksChassis Mount, DIN Rail, PanelDIN Rail300-25°C~100°CTray2009FN 3026yesActiveNot ApplicableTerminal BlockNOT SPECIFIEDGeneral Purpose65mm50A60HzTerminal Block300VCSA, ENEC, URSingle Stage2.5mA520V50AThree Phase (Delta)60Hz2000 V93.7mm177mmRoHS CompliantIP00-------
-
10 WeeksChassis, Chassis MountChassis Mount300-25°C~100°CTray2007FN 3025yesActiveNot ApplicableWire-General Purpose50mm20A60HzTerminal Block300VCSA, ENEC, URSingle Stage2.5mA520V20AThree Phase (Delta)DC~60Hz-78mm150mmRoHS CompliantIP0011kW520V3NoNo SVHC-
-
10 WeeksDIN RailDIN Rail--25°C~100°CTray2009FN 3026yesActiveNot ApplicableWire-General Purpose50mm20A60HzTerminal Block300VCSA, ENEC, URSingle Stage400μA520V20AThree Phase (Delta)60Hz2000 V78mm150mmRoHS CompliantIP00-520V-No-L150.0XB50.0XH78.0 (mm)/L5.906XB1.969XH3.071 (inch)
-
10 WeeksChassis Mount, DIN RailDIN Rail300-25°C~100°CTray2009FN 3026yesActiveNot ApplicableWire-General Purpose50mm10A60HzTerminal Block300VCSA, ENEC, URSingle Stage400μA520V10AThree Phase (Delta)60Hz2000 V87.7mm150mmRoHS Compliant----No-L150.0XB50.0XH78.0 (mm)/L5.906XB1.969XH3.071 (inch)
Popular Search Part Number
Related Keywords
Search Tags
Latest News
-
02 April 2024
TPS54202DDCR Alternatives, Characteristics, Layout and TPS54202DDCR vs TPS54202DDCT
Ⅰ. What is TPS54202DDCR?Ⅱ. Functional modes of TPS54202DDCRⅢ. Characteristics of TPS54202DDCRⅣ. How to reduce the noise of TPS54202DDCR?Ⅴ. Comparison between TPS54202DDCR and TPS54202DDCTⅥ. Layout of TPS54202DDCRⅦ. How to... -
02 April 2024
L6599D Working Principle, Application, Common Faults and Solutions
Ⅰ. Overview of L6599DⅡ. Line sensing function of L6599DⅢ. Working principle of L6599DⅣ. Application of L6599DⅤ. Application circuit of L6599DⅥ. Common faults and solutions of L6599DⅦ. Typical electrical... -
03 April 2024
ADUM1201BRZ-RL7 Alternatives, Specifications, Application and More
Ⅰ. Overview of ADUM1201BRZ-RL7Ⅱ. Specifications of ADUM1201BRZ-RL7Ⅲ. Propagation delay-related parametersⅣ. Application of ADUM1201BRZ-RL7Ⅴ. How to evaluate the performance of ADUM1201BRZ-RL7?Ⅵ. Functional block diagram of ADUM1201BRZ-RL7Ⅶ. PCB layout of... -
03 April 2024
SG3525 PWM IC Characteristics, Internal Structure, Working Principle and SG3525 vs SG3524
Ⅰ. Description of SG3525Ⅱ. Characteristics of SG3525Ⅲ. Internal structure and working principle of SG3525Ⅳ. Representative block diagram of SG3525Ⅴ. Application circuit of SG3525Ⅵ. How to adjust the frequency...
Help you to save your cost and time.
Reliable package for your goods.
Fast Reliable Delivery to save time.
Quality premium after-sale service.