59569-101001

Amphenol FCI 59569-101001

Part Number:
59569-101001
Manufacturer:
Amphenol FCI
Ventron No:
8984263-59569-101001
Description:
Metral® 4000 Series Header, Male Pins Press-Fit Gold Natural 30.0μin 0.76μm 36 Positions Pitch: 0.079 2.00mm -55°C~105°C Tube Through Hole
ECAD Model:
Datasheet:
59569 Series Drawing

Quick Request Quote

Please send RFQ , We will respond immediately.

Part Number
Quantity
Company
E-mail
Phone
Comments
Specifications
Amphenol FCI 59569-101001 technical specifications, attributes, parameters and parts with similar specifications to Amphenol FCI 59569-101001.
  • Contact Plating
    Gold
  • Mount
    Through Hole
  • Mounting Type
    Through Hole
  • Housing Material
    Polymer
  • Operating Temperature
    -55°C~105°C
  • Packaging
    Tube
  • Series
    Metral® 4000
  • Feature
    Shielded
  • Part Status
    Obsolete
  • Moisture Sensitivity Level (MSL)
    1 (Unlimited)
  • Termination
    Press-Fit
  • Connector Type
    Header, Male Pins
  • Number of Positions
    36
  • Max Operating Temperature
    105°C
  • Min Operating Temperature
    -55°C
  • Color
    Natural
  • Number of Rows
    5
  • Current Rating (Amps)
    1A
  • Pitch
    0.079 2.00mm
  • Number of Positions Loaded
    All
  • Current Rating
    1A
  • Contact Finish
    Gold
  • Connector Style
    High Speed
  • Contact Layout, Typical
    30 Signal, 6 Ground
  • Number of Columns
    6
  • Contact Finish Thickness
    30.0μin 0.76μm
  • Material Flammability Rating
    UL94 V-0
  • RoHS Status
    Non-RoHS Compliant
  • Flammability Rating
    UL94 V-0
  • Lead Free
    Contains Lead
Description
59569-101001 Overview
This product is packaged in a Header, Male Pins box.Through Hole indicates that the device is mounted.An Tube case is utilized for packaging the product.The product is a part of the Metral® 4000 Series.Use it below 105°C.A minimum temperature of -55°C must be maintained for the operation of this device.In many ways, Shielded makes it more powerful.By Through Hole, the part is mounted.Operating temperature is set to -55°C~105°C.

59569-101001 Features
Metral® 4000 series


59569-101001 Applications
There are a lot of Amphenol ICC (FCI)
59569-101001 Backplane Connectors applications.


Communication
Medical technology
Military Technology
Measuring & Control Technology
Instrumentation
Automotive Electronics
Telecommunications
Data Technology
Blowers
Control panels
59569-101001 More Descriptions
Conn Hard Metric HDR 30Signal/5Ground POS 2mm Press Fit ST Thru-Hole Tube
59569-101001LF-M4000SIGHDR1-MOD5RP/FEXT | Amphenol FCI (Amphenol CS) 59569101001LF
Metral® High Speed 4000 Series, Backplane Connectors, Header, Vertical Signal, 5 Row, Press-Fit, 30 Position, Select Load, Extended
59569-101001LF-M4000SIGHDR1-MOD5RP/FEXT ROHS COMPLIANT: YES
59569-101001LF-M4000SIGHDR1-MO METRAL HIGH SPEED
Product Comparison
The three parts on the right have similar specifications to 59569-101001.
  • Image
    Part Number
    Manufacturer
    Contact Plating
    Mount
    Mounting Type
    Housing Material
    Operating Temperature
    Packaging
    Series
    Feature
    Part Status
    Moisture Sensitivity Level (MSL)
    Termination
    Connector Type
    Number of Positions
    Max Operating Temperature
    Min Operating Temperature
    Color
    Number of Rows
    Current Rating (Amps)
    Pitch
    Number of Positions Loaded
    Current Rating
    Contact Finish
    Connector Style
    Contact Layout, Typical
    Number of Columns
    Contact Finish Thickness
    Material Flammability Rating
    RoHS Status
    Flammability Rating
    Lead Free
    Factory Lead Time
    Contact Material
    Orientation
    Number of Contacts
    Length
    Max Current Rating
    Depth
    View Compare
  • 59569-101001
    59569-101001
    Gold
    Through Hole
    Through Hole
    Polymer
    -55°C~105°C
    Tube
    Metral® 4000
    Shielded
    Obsolete
    1 (Unlimited)
    Press-Fit
    Header, Male Pins
    36
    105°C
    -55°C
    Natural
    5
    1A
    0.079 2.00mm
    All
    1A
    Gold
    High Speed
    30 Signal, 6 Ground
    6
    30.0μin 0.76μm
    UL94 V-0
    Non-RoHS Compliant
    UL94 V-0
    Contains Lead
    -
    -
    -
    -
    -
    -
    -
    -
  • 59566-5003LF
    GXT, Gold, Tin
    Through Hole
    Through Hole
    Polymer
    -55°C~105°C
    Tube
    Metral® 4000
    -
    Active
    1 (Unlimited)
    Press-Fit
    Header, Male Pins
    36
    105°C
    -55°C
    Natural
    6
    -
    0.079 2.00mm
    All
    -
    Gold or Gold, GXT™
    High Speed
    30 Signal, 6 Ground
    -
    50.0μin 1.27μm
    UL94 V-0
    RoHS Compliant
    UL94 V-0
    -
    10 Weeks
    Bronze
    Straight
    30
    11.88mm
    -
    -
  • 59569-101001LF
    GXT, Gold, Tin
    Through Hole
    Through Hole
    Polymer
    -55°C~105°C
    Tube
    Metral® 4000
    Shielded
    Active
    1 (Unlimited)
    Press-Fit
    Header, Male Pins
    36
    105°C
    -55°C
    Natural
    5
    1A
    0.079 2.00mm
    All
    1A
    Gold
    High Speed
    30 Signal, 6 Ground
    6
    30.0μin 0.76μm
    UL94 V-0
    RoHS Compliant
    UL94 V-0
    Lead Free
    10 Weeks
    Bronze
    Straight
    30
    18.8mm
    1A
    -
  • 59566-1005LF
    Gold, Tin
    Through Hole
    Through Hole
    Polymer
    -55°C~105°C
    Tube
    Metral® 4000
    Shielded
    Active
    1 (Unlimited)
    Press-Fit
    Header, Male Pins
    36
    105°C
    -55°C
    Natural
    5
    1A
    0.079 2.00mm
    34
    1A
    Gold
    High Speed
    30 Signal, 6 Ground
    6
    30.0μin 0.76μm
    UL94 V-0
    RoHS Compliant
    UL94 V-0
    -
    10 Weeks
    Bronze
    Straight
    30
    11.88mm
    -
    17.8mm
Certification
  • ISO 9001
  • ISO 13485
  • ISO 45001
  • ASA
  • ESD
  • DUNS
  • SMTA
  • ROHS

Latest News

  • 20 October 2023

    TNY268PN Switcher: Symbol, Features, Manufacturer and Applications

    Ⅰ. Overview of TNY268PN switcherⅡ. TNY268PN symbol, footprint and pin configurationⅢ. Technical parameters of TNY268PN switcherⅣ. What are the features of TNY268PN switcher?Ⅴ. Manufacturer of TNY268PN switcherⅥ. What...
  • 20 October 2023

    A Comprehensive Introduction to MJE2955T Transistor

    Ⅰ. Overview of MJE2955T transistorⅡ. Symbol, footprint and pin configuration of MJE2955T transistorⅢ. Technical parameters of MJE2955T transistorⅣ. Features of MJE2955T transistorⅤ. Working principle of MJE2955T transistorⅥ. Absolute...
  • 23 October 2023

    UA741CP Operational Amplifier: Symbol, Equivalent, Dimensions and Applications

    Ⅰ. What is UA741CP operational amplifier?Ⅱ. Symbol and footprint of UA741CP operational amplifierⅢ. Technical parameters of UA741CP operational amplifierⅣ. What are the features of UA741CP operational amplifier?Ⅴ. Dimensions...
  • 23 October 2023

    A Basic Overview of SN74LS00N NAND Gates

    Ⅰ. What are logic gates and NAND gates?Ⅱ. Overview of SN74LS00N NAND gatesⅢ. Symbol and footprint of SN74LS00N NAND gatesⅣ. Technical parameters of SN74LS00N NAND gatesⅤ. Features of...
  • cost

    Help you to save your cost and time.

  • package

    Reliable package for your goods.

  • fast

    Fast Reliable Delivery to save time.

  • service

    Quality premium after-sale service.