F-118X

Triad Magnetics F-118X

Part Number:
F-118X
Manufacturer:
Triad Magnetics
Ventron No:
7510652-F-118X
Description:
F-118X datasheet pdf and Power Transformers product details from Triad Magnetics stock available at Ventron
ECAD Model:
Datasheet:
F-118X

Quick Request Quote

Please send RFQ , We will respond immediately.

Part Number
Quantity
Company
E-mail
Phone
Comments
Specifications
Triad Magnetics F-118X technical specifications, attributes, parameters and parts with similar specifications to Triad Magnetics F-118X.
  • Factory Lead Time
    17 Weeks
  • Mount
    Flanges, Panel
  • Mounting Type
    Chassis Mount
  • Number of Pins
    5
  • Weight
    1.3lbs 589.7g
  • Packaging
    Bulk
  • Series
    Single Secondary
  • Size / Dimension
    82.55mm Lx50.80mm W
  • Part Status
    Active
  • Moisture Sensitivity Level (MSL)
    Not Applicable
  • Termination
    Wire
  • Max Operating Temperature
    130°C
  • Min Operating Temperature
    0°C
  • Power Rating
    16.8W
  • Current Rating
    700mA
  • Termination Style
    Wire Leads
  • Approval Agency
    UL
  • Voltage - Isolation
    1500Vrms
  • Output Voltage
    24V
  • Current - Output (Max)
    700mA
  • Element Configuration
    Single
  • Output Current
    700mA
  • Power - Max
    16.8VA
  • Nominal Input Voltage
    115V
  • Voltage - Primary
    115V
  • Primary Winding(s)
    Single
  • Center Tap
    Yes
  • Voltage - Secondary (Full Load)
    24V
  • Secondary Winding(s)
    Single
  • Height
    50.8mm
  • Height Seated (Max)
    50.80mm
  • Length
    82.55mm
  • Width
    50.8mm
  • REACH SVHC
    No SVHC
  • RoHS Status
    ROHS3 Compliant
  • Lead Free
    Lead Free
Description
F-118X Overview
This product is manufactured by Triad Magnetics and belongs to the category of Power Transformers. The images we provide are for reference only, for detailed product information please see specification sheet F-118X or the datasheet in PDF format. As a professional electronic components distributor, Ventron has five million electronic components available. Additionally, we have over 500,000 electronic components in stock ready for immediate shipment. If you have requirements, you can send us a quotation form to get the price of F-118X. We attach great importance to our customers' purchasing experience and are willing to establish a long-term cooperative relationship with you. If you have any questions or requirements, please feel free to contact us.
F-118X More Descriptions
Power Transformer 1500Vrms 16.8VA 5 Terminal Wire Lead Flange Mount
Power Transformer; Output Current:0.7A; Output Voltage:24V; Supply Voltage:115V; Series:F; Transformer Type:Power; Transformer Mounting:Chassis; Leaded Process Compatible:No; Peak Reflow Compatible (260 C):No ;RoHS Compliant: No
Transformer; Chassis; Pri:115V; Sec:24VCT; Sec:0.7A; Lead; 50/60Hz; 3-1/4In.In.W; 2In.In Triad Magnetics offers a full choice of TRIAD power supply transformers for direct use or in transformer, rectifier, or filter circuits. Other available secondary voltages include control, filament and low-level signaling in standard values. The transformers are single primary with single and multiple secondaries in standard size and weight configurations. Connections: Leads.     The power supply transformers for direct use or in transformer, rectifier, or filter circuits.other available secondary voltages include control, filament and low level signaling in standard values. The transformers are single primary with single and multiple secondaries in standard size and weight configurations.  
Certification
  • ISO 9001
  • ISO 13485
  • ISO 45001
  • ASA
  • ESD
  • DUNS
  • SMTA
  • ROHS

Latest News

  • 19 January 2024

    TXB0104PWR Alternatives, Package, Specifications and Applications

    Ⅰ. TXB0104PWR overviewⅡ. Operating principle of TXB0104PWRⅢ. Package of TXB0104PWRⅣ. Specifications of TXB0104PWRⅤ. How to use TXB0104PWR?Ⅵ. What are the applications of TXB0104PWR?Ⅶ. How does TXB0104PWR realize automatic...
  • 19 January 2024

    The Best Tutorial for ISO3082DWR

    Ⅰ. Overview of ISO3082DWRⅡ. Technical parameters of ISO3082DWRⅢ. What are the characteristics of ISO3082DWR?Ⅳ. How does ISO3082DWR work?Ⅴ. ISO3082DWR symbol, footprint and pin configurationⅥ. Layout principles of ISO3082DWRⅦ....
  • 22 January 2024

    What You Need to Know About the MMBT3904 Transistor

    Ⅰ. MMBT3904 descriptionⅡ. What is the pin configuration of MMBT3904?Ⅲ. Specifications of MMBT3904Ⅳ. Typical circuit schematic of MMBT3904Ⅴ. Where is MMBT3904 used?Ⅵ. Absolute maximum ratings of MMBT3904Ⅶ. What...
  • 22 January 2024

    LM317T Voltage Regulator: Functions, Usage, Applications and LM317T vs LM317

    Ⅰ. Overview of LM317TⅡ. What functions does LM317T have?Ⅲ. Technical parameters of LM317T voltage regulatorⅣ. Circuit of LM317T voltage regulatorⅤ. What is the difference between LM317T and LM317?Ⅵ....
  • cost

    Help you to save your cost and time.

  • package

    Reliable package for your goods.

  • fast

    Fast Reliable Delivery to save time.

  • service

    Quality premium after-sale service.