EAP-06-000-D

Cosel USA, Inc. EAP-06-000-D

Part Number:
EAP-06-000-D
Manufacturer:
Cosel USA, Inc.
Ventron No:
7197691-EAP-06-000-D
Description:
EAP-06-000-D datasheet pdf and Power Line Filter Modules product details from Cosel USA, Inc. stock available at Ventron
ECAD Model:
Datasheet:
EAP-06-000-D

Quick Request Quote

Please send RFQ , We will respond immediately.

Part Number
Quantity
Company
E-mail
Phone
Comments
Specifications
Cosel USA, Inc. EAP-06-000-D technical specifications, attributes, parameters and parts with similar specifications to Cosel USA, Inc. EAP-06-000-D.
  • Factory Lead Time
    6 Weeks
  • Mounting Type
    DIN Rail
  • Operating Temperature
    -40°C~85°C
  • Packaging
    Box
  • Published
    2010
  • Series
    EAP
  • Pbfree Code
    yes
  • Part Status
    Active
  • Moisture Sensitivity Level (MSL)
    Not Applicable
  • Termination
    Screw
  • Applications
    General Purpose
  • Voltage - Rated DC
    250V
  • Reach Compliance Code
    unknown
  • Current Rating
    6A
  • Termination Style
    Terminal Block
  • Voltage - Rated AC
    250V
  • Approval Agency
    cURus, VDE
  • Physical Dimension
    L85.0XB39.0XH30.0 (mm)/L3.346XB1.535XH1.181 (inch)
  • Operating Frequency
    60Hz Hz
  • Configuration
    Single Stage
  • Leakage Current
    5μA
  • Filter Type
    Single Phase
  • High Pot
    2500 V
  • Height
    30mm
  • Length
    85mm
  • RoHS Status
    ROHS3 Compliant
  • Lead Free
    Lead Free
Description
EAP-06-000-D Overview
This product is manufactured by Cosel USA, Inc., an esteemed organization known for producing high-quality electronic components. The item in question is a Power Line Filter Module, a critical component used to maintain power integrity. The module comes in a box packaging and was first published in 2010. It belongs to the EAP series and is not sensitive to moisture levels. The Power Line Filter Module is designed for general purpose applications and features a terminal block termination style. It has a voltage rating of 250V for both high potency and rated AC. The length of the module is 85mm, making it compact and easy to install. Additionally, it complies with the ROHS3 standard, ensuring that it adheres to modern environmental protection regulations.
EAP-06-000-D More Descriptions
Power Line Filter EMI/EMC 60Hz 6A 250VAC/250VDC Terminal Block DIN Rail
Small,High-voltage pulses common mode noise filter (1-Stage filter) (DIN Rail)
250 V 60 HZ SINGLE PHASE EMI FILTER
Product Comparison
The three parts on the right have similar specifications to EAP-06-000-D.
  • Image
    Part Number
    Manufacturer
    Factory Lead Time
    Mounting Type
    Operating Temperature
    Packaging
    Published
    Series
    Pbfree Code
    Part Status
    Moisture Sensitivity Level (MSL)
    Termination
    Applications
    Voltage - Rated DC
    Reach Compliance Code
    Current Rating
    Termination Style
    Voltage - Rated AC
    Approval Agency
    Physical Dimension
    Operating Frequency
    Configuration
    Leakage Current
    Filter Type
    High Pot
    Height
    Length
    RoHS Status
    Lead Free
    Capacitance
    View Compare
  • EAP-06-000-D
    EAP-06-000-D
    6 Weeks
    DIN Rail
    -40°C~85°C
    Box
    2010
    EAP
    yes
    Active
    Not Applicable
    Screw
    General Purpose
    250V
    unknown
    6A
    Terminal Block
    250V
    cURus, VDE
    L85.0XB39.0XH30.0 (mm)/L3.346XB1.535XH1.181 (inch)
    60Hz Hz
    Single Stage
    5μA
    Single Phase
    2500 V
    30mm
    85mm
    ROHS3 Compliant
    Lead Free
    -
    -
  • EAP-20-222-D
    6 Weeks
    DIN Rail
    -40°C~85°C
    Box
    2010
    EAP
    yes
    Active
    Not Applicable
    Screw
    General Purpose
    250V
    unknown
    20A
    Terminal Block
    250V
    cURus, VDE
    L85.0XB39.0XH30.0 (mm)/L3.346XB1.535XH1.181 (inch)
    60Hz Hz
    Single Stage
    250μA
    Single Phase
    2500 V
    30mm
    85mm
    ROHS3 Compliant
    -
    2.2nF
  • EAP-03-101
    6 Weeks
    Chassis Mount
    -40°C~85°C
    Box
    2010
    EAP
    yes
    Active
    Not Applicable
    Screw
    General Purpose
    250V
    unknown
    3A
    Terminal Block
    250V
    cURus, VDE
    L85.0XB39.0XH30.0 (mm)/L3.346XB1.535XH1.181 (inch)
    60Hz Hz
    Single Stage
    12.5μA
    Single Phase
    2500 V
    30mm
    85mm
    ROHS3 Compliant
    Lead Free
    100pF
  • EAP-30-681-D
    6 Weeks
    DIN Rail
    -40°C~85°C
    Box
    2010
    EAP
    yes
    Active
    Not Applicable
    Screw
    General Purpose
    250V
    unknown
    30A
    Terminal Block
    250V
    cURus, VDE
    L85.0XB39.0XH30.0 (mm)/L3.346XB1.535XH1.181 (inch)
    60Hz Hz
    Single Stage
    75.5μA
    Single Phase
    2500 V
    30mm
    85mm
    ROHS3 Compliant
    -
    680pF
Certification
  • ISO 9001
  • ISO 13485
  • ISO 45001
  • ASA
  • ESD
  • DUNS
  • SMTA
  • ROHS

Latest News

  • 29 February 2024

    TPS3808G01DBVR: A Powerful Power Monitoring Reset Chip

    Ⅰ. What is TPS3808G01DBVR?Ⅱ. Functions of the TPS3808G01DBVRⅢ. TPS3808G01DBVR functional block diagramⅣ. Specifications of TPS3808G01DBVRⅤ. TPS3808G01DBVR shift register application in realityⅥ. Application circuit diagram of TPS3808G01DBVRⅦ. How to...
  • 01 March 2024

    TPS92662AQPHPRQ1 Alternatives, Characteristics, Functions and Other Details

    Ⅰ. Introduction to TPS92662AQPHPRQ1Ⅱ. Characteristics of TPS92662AQPHPRQ1Ⅲ. Functions of TPS92662AQPHPRQ1Ⅳ. Circuit diagram of the TPS92662AQPHPRQ1Ⅴ. How reliable is the TPS92662AQPHPRQ1?Ⅵ. TPS92662AQPHPRQ1 technical parametersⅦ. How does TPS92662AQPHPRQ1 perform fault...
  • 01 March 2024

    BCM89811B1AWMLG Manufacturer, Characteristics, Specifications and Purchase Guide

    Ⅰ. Overview of BCM89811B1AWMLGⅡ. Manufacturer of BCM89811B1AWMLGⅢ. What are the characteristics of BCM89811B1AWMLG?Ⅳ. Where is BCM89811B1AWMLG used?Ⅴ. What is the connection method of BCM89811B1AWMLG?Ⅵ. Specifications of BCM89811B1AWMLGⅦ. Competitive...
  • 04 March 2024

    NCP1377BDR2G Symbol, Operating Principle, Technical Parameters and More

    Ⅰ. NCP1377BDR2G overviewⅡ. Symbol, footprint and pin configuration of NCP1377BDR2GⅢ. Operating principle of NCP1377BDR2GⅣ. Internal circuit architecture of NCP1377BDR2GⅤ. Precautions for the use of NCP1377BDR2GⅥ. Technical parameters of...
  • cost

    Help you to save your cost and time.

  • package

    Reliable package for your goods.

  • fast

    Fast Reliable Delivery to save time.

  • service

    Quality premium after-sale service.