Schaffner EMC Inc. FN258P-7-07
- Part Number:
- FN258P-7-07
- Manufacturer:
- Schaffner EMC Inc.
- Ventron No:
- 3599480-FN258P-7-07
- Description:
- LINE FILTER 7A CHASSIS MOUNT
- Datasheet:
- FN258 Series Datasheet ~
Schaffner EMC Inc. FN258P-7-07 technical specifications, attributes, parameters and parts with similar specifications to Schaffner EMC Inc. FN258P-7-07.
- Factory Lead Time10 Weeks
- MountChassis, Chassis Mount
- Mounting TypeChassis Mount
- Operating Temperature-25°C~100°C
- PackagingTray
- Published2008
- SeriesFN 258
- Pbfree Codeyes
- Part StatusNot For New Designs
- Moisture Sensitivity Level (MSL)1 (Unlimited)
- TerminationWire Leads
- ApplicationsInverters, Power Drive Systems
- Depth50mm
- Current Rating7A
- Frequency60Hz
- Termination StyleTerminal Block
- Voltage - Rated AC277V
- Approval AgencyCSA, ENEC, UR
- Physical DimensionL225.0XB50.0XH126.0 (mm)/L8.858XB1.969XH4.961 (inch)
- ConfigurationTwo Stage
- Max Current Rating7A
- Filter TypeThree Phase (Delta)
- Rated Voltage480V
- Leakage Current (Max)3.3mA
- Frequency - OperatingDC~60Hz
- High Pot2100 V
- Voltage - Rated AC (Phase to Phase)480V
- Height126mm
- Length255mm
- RoHS StatusRoHS Compliant
- RatingsIP20
Images are for reference only.See Product Specifications for product details.If you are interested to buy FN258P-7-07.
FN258P-7-07 More Descriptions
3-Phase 7 A Input Filter Wire Lead Low Leakage | Schaffner FN258P-7-07
3 Phase Low Leakage Book Style Filter 480Vac, 7A, Wire,
Power Line Filters 7A WIRE 3-PHASE AND NEUTRAL
3 Phase Low Leakage Book Style Filter 480Vac, 7A, Wire,
Power Line Filters 7A WIRE 3-PHASE AND NEUTRAL
The three parts on the right have similar specifications to FN258P-7-07.
-
ImagePart NumberManufacturerFactory Lead TimeMountMounting TypeOperating TemperaturePackagingPublishedSeriesPbfree CodePart StatusMoisture Sensitivity Level (MSL)TerminationApplicationsDepthCurrent RatingFrequencyTermination StyleVoltage - Rated ACApproval AgencyPhysical DimensionConfigurationMax Current RatingFilter TypeRated VoltageLeakage Current (Max)Frequency - OperatingHigh PotVoltage - Rated AC (Phase to Phase)HeightLengthRoHS StatusRatingsCurrentVoltage - Rated AC (Phase to Ground/Neutral)WidthMax Operating TemperatureMin Operating TemperatureAdditional FeatureReach Compliance CodeInductanceMax Voltage Rating (AC)View Compare
-
FN258P-7-0710 WeeksChassis, Chassis MountChassis Mount-25°C~100°CTray2008FN 258yesNot For New Designs1 (Unlimited)Wire LeadsInverters, Power Drive Systems50mm7A60HzTerminal Block277VCSA, ENEC, URL225.0XB50.0XH126.0 (mm)/L8.858XB1.969XH4.961 (inch)Two Stage7AThree Phase (Delta)480V3.3mADC~60Hz2100 V480V126mm255mmRoHS CompliantIP20----------
-
--Chassis Mount-25°C~100°CTray2014FN 258yesNot For New Designs1 (Unlimited)-Inverters, Power Drive Systems---Terminal Block-UL; CSA; ENEC-14L440.0XB110.0XH240.0 (mm)/L17.323XB4.331XH9.449 (inch)Single Stage-Three Phase (Delta)480V-DC~60Hz2650 V480V240mm440mmRoHS Compliant-250A277V110mm------
-
5 WeeksChassis, Chassis Mount, FlangesChassis Mount-Tray2002FN 251-Not For New Designs1 (Unlimited)Wire LeadsGeneral Purpose115mm24A60HzTerminal Block, Wire Leads440VURL180XB115XH60 (mm)Two Stage24AThree Phase (Delta)250V0.5mADC~60Hz--60mm180mmRoHS CompliantIP20---100°C-25°CWIRE OUTPUT CONNECTIONSunknown1mH440V
-
10 WeeksChassis, Chassis MountChassis Mount-25°C~100°CTray2008FN 258yesNot For New Designs1 (Unlimited)Wire LeadsInverters, Power Drive Systems60mm30A60HzTerminal Block277VCSA, ENEC, URL305.0XB60.0XH150.0 (mm)/L12.008XB2.362XH5.906 (inch)Two Stage30AThree Phase (Delta)480V0.8mADC~60Hz2100 V480V150mm335mmRoHS CompliantIP20---------
Popular Search Part Number
Related Keywords
Search Tags
Latest News
-
06 March 2024
LIS3DHTR Alternatives, Specifications, Dimensions and Package
Ⅰ. What is LIS3DHTR?Ⅱ. Specifications of LIS3DHTRⅢ. Schematic diagram and working principle of LIS3DHTRⅣ. How to use LIS3DHTR?Ⅴ. Electrical characteristics of LIS3DHTRⅥ. What is the function of FIFO... -
07 March 2024
AMS1117-3.3 Voltage Regulator Instructions for Use: From Principle to Application
Ⅰ. Introduction to AMS1117-3.3Ⅱ. Symbol, footprint and pin configuration of AMS1117-3.3Ⅲ. What are the characteristics of AMS1117-3.3?Ⅳ. How does AMS1117-3.3 work?Ⅴ. Application cases of AMS1117-3.3Ⅵ. How to wire... -
07 March 2024
BTS50085-1TMA Alternatives, Advantages, Usage and Other Details
Ⅰ. Overview of BTS50085-1TMAⅡ. Technical parameters of BTS50085-1TMAⅢ. BTS50085-1TMA input circuitⅣ. What are the advantages of BTS50085-1TMA compared with other similar products?Ⅴ. Usage of BTS50085-1TMAⅥ. How to install... -
08 March 2024
A Complete Guide to the TP4056 Battery Charger Module
Ⅰ. What is TP4056?Ⅱ. Block diagram of TP4056Ⅲ. Main parameters of TP4056Ⅳ. Pins and functions of TP4056Ⅴ. TP4056 charging circuit diagram explanationⅥ. Battery charging process of TP4056Ⅶ. Application...
Help you to save your cost and time.
Reliable package for your goods.
Fast Reliable Delivery to save time.
Quality premium after-sale service.