TE Connectivity Potter & Brumfield Relays W68-X2Q12-20
- Part Number:
- W68-X2Q12-20
- Manufacturer:
- TE Connectivity Potter & Brumfield Relays
- Ventron No:
- 3541963-W68-X2Q12-20
- Description:
- CIR BRKR MAG-HYDR 20A 277VAC
- Datasheet:
- W68-X2Q12-20
TE Connectivity Potter & Brumfield Relays W68-X2Q12-20 technical specifications, attributes, parameters and parts with similar specifications to TE Connectivity Potter & Brumfield Relays W68-X2Q12-20.
- Lifecycle StatusACTIVE (Last Updated: 2 days ago)
- Factory Lead Time17 Weeks
- MountPanel
- Mounting TypePanel Mount
- Weight70.800014g
- SeriesW6
- Published2010
- Part StatusActive
- Moisture Sensitivity Level (MSL)Not Applicable
- TerminationQuick Connect
- Max Operating Temperature85°C
- Min Operating Temperature-40°C
- ColorWhite
- Voltage - Rated277V
- Current Rating20A
- Voltage - Rated AC1.729V
- Approval AgencyUL
- Physical Dimension50.8mm x 38.1mm x 41.66mm
- Actuator TypeLever
- Operating Supply Voltage277V
- Environmental CharacteristicsFUNGUS RESISTANT; MOISTURE RESISTANT
- ELVNon-Compliant
- Number of Poles2
- Breaker TypeMagnetic (Hydraulic Delay)
- Circuit Protection TypeMAGNETIC CIRCUIT BREAKER
- Blow CharacteristicSTANDARD
- Time to Trip20 s
- Rated Breaking Capacity5000 A
- Circuit FunctionSERIES TRIP
- Height50.8mm
- Length51.89mm
- Width38.1mm
- Panel Thickness2.794mm
- REACH SVHCUnknown
- RoHS StatusRoHS Compliant
- Lead FreeContains Lead
We can supply Potter & Brumfield Relays / TE Connectivity W68-X2Q12-20, use the request quote form to request W68-X2Q12-20 pirce, Potter & Brumfield Relays / TE Connectivity Datasheet PDF and lead time.ventronchip.com is a professional electronic components distributor. With 3 Million line items of available electronic components can ship in short lead-time, over 250 thousand part numbers of electronic components in stock for immediately delivery, which may include part number W68-X2Q12-20.The price and lead time for W68-X2Q12-20 depending on the quantity required, availability and warehouse location.
W68-X2Q12-20 More Descriptions
Supplementary Hydraulic Magnetic Breaker Breaker 20A 2P - 3-1393253-4
Circuit Breaker Magnetic Overcurrent 2Pole 20A 277VAC/415VAC/240VAC 4-Pin
Circuit Breaker Magnetic Hydraulic 2Pole 20A 277VAC
Circuit Breaker Hyd/Mag Togl 20A Panel 2 Pole Vol-Rtg 277VAC | TE Connectivity W68-X2Q12-20
Magnetic Circuit Breaker, 2 Pole(S), 20A, 277Vac, Panel Mount
W68 Series White 50.8 mm 2 Pole 20 A Toggle Actuator Magnetic Circuit Breaker
CIRCUIT BREAKER, HYDROMAGNETIC, 2P, 277V, 20A; Product Range: W6 Series; Current Rating: 20A; No. of Poles: 2 Pole; Input Voltage VAC: 277V; Interrupting Capacity: 5kA; Trip Time: 20s; Dielectric Strength: 1.5kV; Operating Voltage: 277VAC
W68-X2Q12-20=M6/M7/M9/W6/W7 Circuit Breaker Type: Magnetic Circuit Function: Series Trip Illuminated: Without Actuator Color: White Operating Voltage: 240 VAC 415 VAC 277 VAC Magnetic Series Trip Without White | Circuit Breaker | Part Number: W68-X2Q12-20 | Internal Number: 3-1393253-4 | TE Connectivity
Circuit Breaker Magnetic Overcurrent 2Pole 20A 277VAC/415VAC/240VAC 4-Pin
Circuit Breaker Magnetic Hydraulic 2Pole 20A 277VAC
Circuit Breaker Hyd/Mag Togl 20A Panel 2 Pole Vol-Rtg 277VAC | TE Connectivity W68-X2Q12-20
Magnetic Circuit Breaker, 2 Pole(S), 20A, 277Vac, Panel Mount
W68 Series White 50.8 mm 2 Pole 20 A Toggle Actuator Magnetic Circuit Breaker
CIRCUIT BREAKER, HYDROMAGNETIC, 2P, 277V, 20A; Product Range: W6 Series; Current Rating: 20A; No. of Poles: 2 Pole; Input Voltage VAC: 277V; Interrupting Capacity: 5kA; Trip Time: 20s; Dielectric Strength: 1.5kV; Operating Voltage: 277VAC
W68-X2Q12-20=M6/M7/M9/W6/W7 Circuit Breaker Type: Magnetic Circuit Function: Series Trip Illuminated: Without Actuator Color: White Operating Voltage: 240 VAC 415 VAC 277 VAC Magnetic Series Trip Without White | Circuit Breaker | Part Number: W68-X2Q12-20 | Internal Number: 3-1393253-4 | TE Connectivity
The three parts on the right have similar specifications to W68-X2Q12-20.
-
ImagePart NumberManufacturerLifecycle StatusFactory Lead TimeMountMounting TypeWeightSeriesPublishedPart StatusMoisture Sensitivity Level (MSL)TerminationMax Operating TemperatureMin Operating TemperatureColorVoltage - RatedCurrent RatingVoltage - Rated ACApproval AgencyPhysical DimensionActuator TypeOperating Supply VoltageEnvironmental CharacteristicsELVNumber of PolesBreaker TypeCircuit Protection TypeBlow CharacteristicTime to TripRated Breaking CapacityCircuit FunctionHeightLengthWidthPanel ThicknessREACH SVHCRoHS StatusLead FreeCurrent Rating (Amps)View Compare
-
W68-X2Q12-20ACTIVE (Last Updated: 2 days ago)17 WeeksPanelPanel Mount70.800014gW62010ActiveNot ApplicableQuick Connect85°C-40°CWhite277V20A1.729VUL50.8mm x 38.1mm x 41.66mmLever277VFUNGUS RESISTANT; MOISTURE RESISTANTNon-Compliant2Magnetic (Hydraulic Delay)MAGNETIC CIRCUIT BREAKERSTANDARD20 s5000 ASERIES TRIP50.8mm51.89mm38.1mm2.794mmUnknownRoHS CompliantContains Lead--
-
----------------------------------Non-RoHS Compliant--
-
-18 Weeks-Panel Mount-W62015Active1 (Unlimited)------277V--Lever---2Magnetic (Hydraulic Delay)----------RoHS Compliant-20A
-
ACTIVE (Last Updated: 3 days ago)17 WeeksPanelPanel Mount-W62009ActiveNot ApplicableQuick Connect85°C-40°C--5A250V--Lever---2Magnetic (Hydraulic Delay)-----50.8mm51.89mm38.1mm2.794mm-Non-RoHS CompliantContains Lead5A
Popular Search Part Number
Related Keywords
Search Tags
Latest News
-
19 October 2023
TIP122 Darlington Transistor: Symbol, Features, Applications and More
Ⅰ. What is Darlington tube?Ⅱ. Overview of TIP122 transistorⅢ. Symbol and footprint of TIP122 transistorⅣ. Technical parameters of TIP122 transistorⅤ. What are the features of TIP122 transistor?Ⅵ. Pin... -
19 October 2023
LM3900N Quadruple Operational Amplifier: Equivalent, Working Principle and LM3900N vs LM3900DR
Ⅰ. Overview of LM3900NⅡ. Symbol and footprint of LM3900NⅢ. Technical parameters of LM3900NⅣ. What are the features of LM3900N?Ⅴ. Pin configuration of LM3900NⅥ. Circuit and working principle of... -
20 October 2023
TNY268PN Switcher: Symbol, Features, Manufacturer and Applications
Ⅰ. Overview of TNY268PN switcherⅡ. TNY268PN symbol, footprint and pin configurationⅢ. Technical parameters of TNY268PN switcherⅣ. What are the features of TNY268PN switcher?Ⅴ. Manufacturer of TNY268PN switcherⅥ. What... -
20 October 2023
A Comprehensive Introduction to MJE2955T Transistor
Ⅰ. Overview of MJE2955T transistorⅡ. Symbol, footprint and pin configuration of MJE2955T transistorⅢ. Technical parameters of MJE2955T transistorⅣ. Features of MJE2955T transistorⅤ. Working principle of MJE2955T transistorⅥ. Absolute...
Help you to save your cost and time.
Reliable package for your goods.
Fast Reliable Delivery to save time.
Quality premium after-sale service.