VI-J3D-CW-F4

Vicor Corporation VI-J3D-CW-F4

Part Number:
VI-J3D-CW-F4
Manufacturer:
Vicor Corporation
Ventron No:
3385070-VI-J3D-CW-F4
Description:
CONVERTER MOD DC/DC 85V 100W
ECAD Model:
Datasheet:
VI-J3D-CW-F4

Quick Request Quote

Please send RFQ , We will respond immediately.

Part Number
Quantity
Company
E-mail
Phone
Comments
Specifications
Vicor Corporation VI-J3D-CW-F4 technical specifications, attributes, parameters and parts with similar specifications to Vicor Corporation VI-J3D-CW-F4.
  • Mount
    Through Hole
  • Mounting Type
    Through Hole
  • Package / Case
    Half Brick
  • Operating Temperature
    -25°C~100°C
  • Packaging
    Bulk
  • Series
    VI-J00™ (100W)
  • Published
    2013
  • Size / Dimension
    2.28Lx1.86W x 1.04 H 57.9mmx47.2mmx26.4mm
  • JESD-609 Code
    e0
  • Feature
    OCP, SCP
  • Pbfree Code
    no
  • Part Status
    Active
  • Moisture Sensitivity Level (MSL)
    Not Applicable
  • Number of Terminations
    9
  • ECCN Code
    EAR99
  • Terminal Finish
    TIN LEAD
  • Applications
    ITE (Commercial)
  • Power (Watts)
    100W
  • Max Power Dissipation
    100W
  • Technology
    HYBRID
  • Terminal Position
    DUAL
  • Terminal Form
    PIN/PEG
  • Peak Reflow Temperature (Cel)
    NOT SPECIFIED
  • Number of Functions
    1
  • Time@Peak Reflow Temperature-Max (s)
    NOT SPECIFIED
  • Base Part Number
    VI-J3D
  • JESD-30 Code
    R-XDMA-P9
  • Number of Outputs
    1
  • Qualification Status
    Not Qualified
  • Efficiency
    90%
  • Voltage - Isolation
    3kV
  • Voltage - Input (Max)
    60V
  • Output Voltage
    85V
  • Max Output Current
    1.18A
  • Voltage - Output 1
    85V
  • Voltage - Input (Min)
    42V
  • Input Voltage-Nom
    48V
  • Trim/Adjustable Output
    YES
  • Height
    26.416mm
  • RoHS Status
    Non-RoHS Compliant
Description
Images are for reference only.See Product Specifications for product details.If you are interested to buy VI-J3D-CW-F4.
VI-J3D-CW-F4 More Descriptions
DC DC CONVERTER 85V 100W
Product Comparison
The three parts on the right have similar specifications to VI-J3D-CW-F4.
  • Image
    Part Number
    Manufacturer
    Mount
    Mounting Type
    Package / Case
    Operating Temperature
    Packaging
    Series
    Published
    Size / Dimension
    JESD-609 Code
    Feature
    Pbfree Code
    Part Status
    Moisture Sensitivity Level (MSL)
    Number of Terminations
    ECCN Code
    Terminal Finish
    Applications
    Power (Watts)
    Max Power Dissipation
    Technology
    Terminal Position
    Terminal Form
    Peak Reflow Temperature (Cel)
    Number of Functions
    Time@Peak Reflow Temperature-Max (s)
    Base Part Number
    JESD-30 Code
    Number of Outputs
    Qualification Status
    Efficiency
    Voltage - Isolation
    Voltage - Input (Max)
    Output Voltage
    Max Output Current
    Voltage - Output 1
    Voltage - Input (Min)
    Input Voltage-Nom
    Trim/Adjustable Output
    Height
    RoHS Status
    Factory Lead Time
    Additional Feature
    Subcategory
    Approval Agency
    Width
    View Compare
  • VI-J3D-CW-F4
    VI-J3D-CW-F4
    Through Hole
    Through Hole
    Half Brick
    -25°C~100°C
    Bulk
    VI-J00™ (100W)
    2013
    2.28Lx1.86W x 1.04 H 57.9mmx47.2mmx26.4mm
    e0
    OCP, SCP
    no
    Active
    Not Applicable
    9
    EAR99
    TIN LEAD
    ITE (Commercial)
    100W
    100W
    HYBRID
    DUAL
    PIN/PEG
    NOT SPECIFIED
    1
    NOT SPECIFIED
    VI-J3D
    R-XDMA-P9
    1
    Not Qualified
    90%
    3kV
    60V
    85V
    1.18A
    85V
    42V
    48V
    YES
    26.416mm
    Non-RoHS Compliant
    -
    -
    -
    -
    -
    -
  • VI-J00-15
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Active
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    16 Weeks
    -
    -
    -
    -
  • VI-J0B-MY-F4
    Through Hole
    Through Hole
    Half Brick
    -55°C~100°C
    Bulk
    VI-J00™ (50W)
    2013
    2.28Lx1.86W x 1.04 H 57.9mmx47.2mmx26.4mm
    -
    OCP, SCP
    -
    Active
    Not Applicable
    -
    -
    -
    ITE (Commercial)
    50W
    50W
    -
    -
    -
    -
    -
    -
    VI-J0B
    -
    1
    -
    90%
    3kV
    20V
    -
    526mA
    95V
    10V
    12V
    -
    26.416mm
    Non-RoHS Compliant
    -
    REMOTE SHUTDOWN
    Power Supply Modules
    TUV, UL
    57.9mm
  • VI-J0B-IX-F3
    Through Hole
    Through Hole
    Half Brick
    -40°C~100°C
    Bulk
    VI-J00™ (75W)
    2013
    2.28Lx1.80W x 0.79 H 57.9mmx45.7mmx20.0mm
    e0
    OCP, SCP
    no
    Active
    Not Applicable
    9
    EAR99
    TIN LEAD
    ITE (Commercial)
    75W
    75W
    HYBRID
    DUAL
    PIN/PEG
    NOT SPECIFIED
    1
    NOT SPECIFIED
    VI-J0B
    R-XDMA-P9
    1
    Not Qualified
    90%
    3kV
    20V
    95V
    790mA
    95V
    10V
    12V
    YES
    20.066mm
    Non-RoHS Compliant
    -
    -
    -
    -
    -
Certification
  • ISO 9001
  • ISO 13485
  • ISO 45001
  • ASA
  • ESD
  • DUNS
  • SMTA
  • ROHS

Latest News

  • 13 March 2024

    74HC595: Efficient 8-Bit Shift Register Chip

    Ⅰ. Overview of 74HC595Ⅱ. Pins and functions of 74HC595Ⅲ. Logic diagram of 74HC595Ⅳ. Application of 74HC595Ⅴ. Design of multi-digit LED display based on 74HC595Ⅵ. LED driver circuit design...
  • 14 March 2024

    Comprehensive Understanding of the 78M05 Chip

    Ⅰ. Development history of linear voltage regulatorsⅡ. Introduction to 78M05Ⅲ. Pin layout of 78M05Ⅳ. External components of 78M05Ⅴ. Technical key points of 78M05Ⅵ. Internal circuit diagram of 78M05Ⅶ....
  • 14 March 2024

    What is the NE555 and How Does it Work?

    Ⅰ. The birth background of NE555Ⅱ. Introduction to NE555Ⅲ. Design of NE555 timerⅣ. Internal composition of NE555Ⅴ. Operating modes of the NE555Ⅵ. Working principle of NE555Ⅶ. Application of...
  • 15 March 2024

    ULN2003 Alternatives, Characteristics, Working Principle and Application

    Ⅰ. ULN2003 overviewⅡ. What are the characteristics of ULN2003?Ⅲ. Pin diagram and functions of ULN2003Ⅳ. Working principle and function of ULN2003Ⅴ. ULN2003 drive circuit diagramⅥ. Where is ULN2003...
  • cost

    Help you to save your cost and time.

  • package

    Reliable package for your goods.

  • fast

    Fast Reliable Delivery to save time.

  • service