EPSON RX6110SA:B3 PURE SN
- Part Number:
- RX6110SA:B3 PURE SN
- Manufacturer:
- EPSON
- Ventron No:
- 3625573-RX6110SA:B3 PURE SN
- Description:
- IC RTC CLK/CALENDAR I2C 14-SOP
- Datasheet:
- RX6110SA:B3 PURE SN
EPSON RX6110SA:B3 PURE SN technical specifications, attributes, parameters and parts with similar specifications to EPSON RX6110SA:B3 PURE SN.
- Factory Lead Time13 Weeks
- Mounting TypeSurface Mount
- Package / Case14-SOIC (0.197, 5.00mm Width)
- Surface MountYES
- Operating Temperature-40°C~85°C
- PackagingTape & Reel (TR)
- SeriesRX6110SA
- JESD-609 Codee3
- FeatureAlarm, Leap Year, RAM
- Part StatusActive
- Moisture Sensitivity Level (MSL)1 (Unlimited)
- Number of Terminations14
- Terminal FinishTin (Sn)
- TechnologyCMOS
- Voltage - Supply1.6V~5.5V
- Terminal PositionDUAL
- Peak Reflow Temperature (Cel)NOT SPECIFIED
- Supply Voltage3V
- Terminal Pitch1.27mm
- Reflow Temperature-Max (s)NOT SPECIFIED
- JESD-30 CodeR-PDSO-G14
- InterfaceI2C, 2-Wire Serial
- Memory Size16B
- Time FormatHH:MM:SS (24 hr)
- Date FormatYY-MM-DD-dd
- Current - Timekeeping (Max)0.25μA~0.27μA @ 3V~5V
- Voltage - Supply, Battery1.1V~5.5V
- Information Access MethodI2C; SERIAL
- Height Seated (Max)3.3mm
- Length10.1mm
- Width5mm
- RoHS StatusROHS3 Compliant
RX6110SA:B3 PURE SN Overview
The mounting type for this device is surface mount, which means it can be easily attached to a surface without the need for additional hardware. Its JESD-609 code is e3, indicating that it is compliant with industry standards for electrostatic discharge. One of its key features is an alarm function, which can be set to alert the user at specific times. It also has a built-in leap year function, ensuring accurate timekeeping even during leap years. With a moisture sensitivity level of 1 (unlimited), this device can withstand exposure to high levels of moisture without damage. It has 14 terminations and a tin (Sn) terminal finish. The reflow temperature is not specified, and it can be accessed through an I2C or 2-wire serial interface. The time format is HH:MM:SS in 24-hour format, and the information can be accessed through either I2C or serial methods.
RX6110SA:B3 PURE SN Features
14-SOIC (0.197, 5.00mm Width) package
14 terminations
RX6110SA series
RX6110SA:B3 PURE SN Applications
There are a lot of EPSON RX6110SA:B3 PURE SN Real Time Clocks applications.
Digital voice recorders
Digital cameras
Network Appliance
GPS/Telematics Devices
Network powered devices
High duration timers
Utility Meter
Medical Equipment
Low standby power applications
Portable instruments
The mounting type for this device is surface mount, which means it can be easily attached to a surface without the need for additional hardware. Its JESD-609 code is e3, indicating that it is compliant with industry standards for electrostatic discharge. One of its key features is an alarm function, which can be set to alert the user at specific times. It also has a built-in leap year function, ensuring accurate timekeeping even during leap years. With a moisture sensitivity level of 1 (unlimited), this device can withstand exposure to high levels of moisture without damage. It has 14 terminations and a tin (Sn) terminal finish. The reflow temperature is not specified, and it can be accessed through an I2C or 2-wire serial interface. The time format is HH:MM:SS in 24-hour format, and the information can be accessed through either I2C or serial methods.
RX6110SA:B3 PURE SN Features
14-SOIC (0.197, 5.00mm Width) package
14 terminations
RX6110SA series
RX6110SA:B3 PURE SN Applications
There are a lot of EPSON RX6110SA:B3 PURE SN Real Time Clocks applications.
Digital voice recorders
Digital cameras
Network Appliance
GPS/Telematics Devices
Network powered devices
High duration timers
Utility Meter
Medical Equipment
Low standby power applications
Portable instruments
RX6110SA:B3 PURE SN More Descriptions
REAL TIME CLOCK 3.0V 5 /-23PPM 250TR
Real Time Clock, CMOS, PDSO14
IC RTC CLK/CALENDAR I2C 14-SOP
Real Time Clock, CMOS, PDSO14
IC RTC CLK/CALENDAR I2C 14-SOP
Popular Search Part Number
Related Keywords
Search Tags
Latest News
-
18 October 2023
What Is CD4017BE CMOS Counter And How It Works?
Ⅰ. Overview of CD4017BE counterⅡ. Symbol, footprint and pin configuration of CD4017BEⅢ. Technical parameters of CD4017BEⅣ. What are the features of CD4017BE?Ⅴ. How does CD4017BE work?Ⅵ. What are... -
18 October 2023
Get to Know the MOC3063 Triac Driver
Ⅰ. What is an optocoupler?Ⅱ. Overview of MOC3063 optocouplerⅢ. Symbol, footprint and pin configuration of MOC3063Ⅳ. Technical parameters of MOC3063Ⅴ. What are the features of MOC3063?Ⅵ. Working principle... -
19 October 2023
TIP122 Darlington Transistor: Symbol, Features, Applications and More
Ⅰ. What is Darlington tube?Ⅱ. Overview of TIP122 transistorⅢ. Symbol and footprint of TIP122 transistorⅣ. Technical parameters of TIP122 transistorⅤ. What are the features of TIP122 transistor?Ⅵ. Pin... -
19 October 2023
LM3900N Quadruple Operational Amplifier: Equivalent, Working Principle and LM3900N vs LM3900DR
Ⅰ. Overview of LM3900NⅡ. Symbol and footprint of LM3900NⅢ. Technical parameters of LM3900NⅣ. What are the features of LM3900N?Ⅴ. Pin configuration of LM3900NⅥ. Circuit and working principle of...
Help you to save your cost and time.
Reliable package for your goods.
Fast Reliable Delivery to save time.
Quality premium after-sale service.