0 Shopping Cart

TE Connectivity Raychem Cable Protection RBK-ILS-125-NR2-0-STK

Part Number:

RBK-ILS-125-NR2-0-STK

Manufacturer:

TE Connectivity Raychem Cable Protection

Ventron No:

200011-RBK-ILS-125-NR2-0-STK

Description:

RBK-ILS-125-NR2-0-STK

Datasheet:

RBK-ILS-125-NR2-0-STK

Payment:

Payment

Delivery:

Delivery

Quick Request Quote

Please send RFQ , We will respond immediately.

Part Number
Quantity
Company
E-mail
Phone
Comments
  • One Stop Service

    One Stop Service

  • Competitive Price

    Competitive Price

  • Source Traceability

    Source Traceability

  • Same Day Delivery

    Same Day Delivery

Specifications

TE Connectivity Raychem Cable Protection RBK-ILS-125-NR2-0-STK technical specifications, attributes, parameters and parts with similar specifications to TE Connectivity Raychem Cable Protection RBK-ILS-125-NR2-0-STK.

  • Lifecycle Status
    ACTIVE (Last Updated: 3 days ago)
  • Material

    In electronic components, "Material" refers to the substance or composition used to construct the component. It determines the electrical, mechanical, and thermal properties of the component.

    Polyolefin (PO), Irradiated
  • Operating Temperature

    Operating Temperature is the range of temperatures at which an electronic component can function properly. It is typically specified in degrees Celsius (°C) and indicates the minimum and maximum temperatures at which the component can operate without experiencing damage or degradation. Operating Temperature is an important parameter to consider when designing electronic circuits, as it ensures that the components will function reliably in the intended operating environment.

    -40°C~125°C
  • Packaging
    Bulk
  • Series

    Series, in the context of electronic components, refers to the arrangement of components in a circuit. When components are connected in series, they form a single path for current to flow through. The total resistance of a series circuit is the sum of the individual resistances of each component. Series connections are often used to control the flow of current in a circuit, as the total resistance can be adjusted by changing the number or type of components in the series.

    RBK-ILS
  • Published
    2010
  • Feature
    Abrasion and Cut Resistant, Adhesive Lined, Flame Retardant
  • Part Status

    Part Status is an electronic component parameter that indicates the availability and production status of a component. It is typically used to inform customers about the availability of a component, whether it is in production, end-of-life, or obsolete. Part Status can also provide information about any restrictions or limitations on the component's use, such as whether it is only available for certain applications or if it has been discontinued.

    Active
  • Max Operating Temperature
    125°C
  • Min Operating Temperature
    -40°C
  • Color
    Black
  • ELV
    Compliant
  • Shrinkage Ratio
    4 to 1
  • Shrink Temperature
    135°C
  • Diameter - Inner, Supplied
    0.295 (7.49mm)
  • Diameter - Inner, Recovered
    0.136 (3.45mm)
  • Recovered Wall Thickness
    0.055 1.40mm
  • RoHS Status
    RoHS Compliant

Description

RBK-ILS-125-NR2-0-STK Overview
This product is manufactured by TE Connectivity Raychem Cable Protection and belongs to the category of Heat Shrink Tubing. The images we provide are for reference only, for detailed product information please see specification sheet RBK-ILS-125-NR2-0-STK or the datasheet in PDF format. As a professional electronic components distributor, Ventron has five million electronic components available. Additionally, we have over 500,000 electronic components in stock ready for immediate shipment. If you have requirements, you can send us a quotation form to get the price of RBK-ILS-125-NR2-0-STK. We attach great importance to our customers' purchasing experience and are willing to establish a long-term cooperative relationship with you. If you have any questions or requirements, please feel free to contact us.

Certification

  • ISO 9001
  • ISO 13485
  • ISO 45001
  • ASA
  • ESD
  • DUNS
  • SMTA
  • ROHS

Latest News

  • 25 February 2026
    10/2 or 10/3? Choosing the Right Wire for Air Conditioner
      What Does 10/2 and 10/3 Wire Mean? 10/2 or 10/3 Wire for Air Conditioners Factors Affecting the Wire Size Selection for Air Conditioners What Wire Sizes Are Needed for Different Sizes...
  • 26 February 2026
    A76 Battery Specifications, Equivalents and Applications
      What is an A76 Battery? A76 Battery Specifications Features of A76 Battery A76 Battery Equivalents A76 Battery Applications Advantages of Using A76 Battery Where to Buy A76 Batteries? A76 Battery Manufacturers A76 Battery Handling and Storage...
  • 27 February 2026
    CR123A vs 123A A Comprehensive Comparison Guide
      CR123A Battery Overview 123A Battery Overview Detailed Comparison Between CR123A and 123A Batteries CR123A and 123A Battery Equivalence Analysis Are CR123A and 123A Batteries Interchangeable? How to Choose Between CR123A and 123A Batteries? Frequently...
  • 03 March 2026
    14 Gauge Wire Amps, Types, Breaker Limits, and Common Uses
      What is 14 Gauge Wire? How Many Amps Can 14 Gauge Wire Handle? 14 AWG Ampacity and Temperature Ratings Breaker Limits and Code Rules for 14 AWG Types of 14 Gauge Wire Comparison...