Honeywell Microelectronics & Precision Sensors PPT0500GXX2VA
- Part Number:
- PPT0500GXX2VA
- Manufacturer:
- Honeywell Microelectronics & Precision Sensors
- Ventron No:
- 4463557-PPT0500GXX2VA
- Description:
- PRESSURE TRANSDUCER
- Datasheet:
- PPT/PPT2 Comparison Summary PPT/PPTR User Manual
Honeywell Microelectronics & Precision Sensors PPT0500GXX2VA technical specifications, attributes, parameters and parts with similar specifications to Honeywell Microelectronics & Precision Sensors PPT0500GXX2VA.
- Factory Lead Time6 Weeks
- Package / CaseModule Cube
- Operating Temperature-40°C~85°C
- Published2012
- Part StatusObsolete
- Moisture Sensitivity Level (MSL)1 (Unlimited)
- ApplicationsIndustrial Automation
- Voltage - Supply5.5V~30V
- Output0 V ~ 5 V
- Termination StyleConnector
- Output TypeAnalog, RS-232
- Accuracy±0.05%
- Operating Pressure500PSI (3447.38kPa)
- Pressure TypeVented Gauge
- Port StyleThreaded
- Port SizeFemale - 1/8" 3.18mm Swagelok? Dual
- Maximum Pressure600PSI (4136.85kPa)
- Max Pressure600 PSI
- RoHS StatusNon-RoHS Compliant
PPT0500GXX2VA Overview
Module Cube includes this transducer for convenience. Reliable performance can be assured by setting the transducers to -40°C~85°C. A supply voltage of 5.5V~30V is sufficient for the transducers to operate well.
PPT0500GXX2VA Features
Moisture Sensitivity Level: 1 (Unlimited)
Package / Case: Module Cube
Operating Temperature: -40°C~85°C
Operating Pressure: 500PSI (3447.38kPa)
PPT0500GXX2VA Applications
There are a lot of Honeywell Aerospace
PPT0500GXX2VA Transducers applications.
Leisure, Sports, and Fitness Activity Identification
Weather Forecasting
Hydrogen Storage
Refrigerant pressure monitoring in HVAC/R systems
Dry air system pressure, process controls and automation
Dry air system monitoring
Hydraulic, brake, and engine oil fluid pressure monitoring
Air brake pressure monitoring
Vertical velocity indication (e.g. rise/sink speed)
Internet of things
Module Cube includes this transducer for convenience. Reliable performance can be assured by setting the transducers to -40°C~85°C. A supply voltage of 5.5V~30V is sufficient for the transducers to operate well.
PPT0500GXX2VA Features
Moisture Sensitivity Level: 1 (Unlimited)
Package / Case: Module Cube
Operating Temperature: -40°C~85°C
Operating Pressure: 500PSI (3447.38kPa)
PPT0500GXX2VA Applications
There are a lot of Honeywell Aerospace
PPT0500GXX2VA Transducers applications.
Leisure, Sports, and Fitness Activity Identification
Weather Forecasting
Hydrogen Storage
Refrigerant pressure monitoring in HVAC/R systems
Dry air system pressure, process controls and automation
Dry air system monitoring
Hydraulic, brake, and engine oil fluid pressure monitoring
Air brake pressure monitoring
Vertical velocity indication (e.g. rise/sink speed)
Internet of things
PPT0500GXX2VA More Descriptions
PRESSURE TRANSDUCER
The three parts on the right have similar specifications to PPT0500GXX2VA.
-
ImagePart NumberManufacturerFactory Lead TimePackage / CaseOperating TemperaturePublishedPart StatusMoisture Sensitivity Level (MSL)ApplicationsVoltage - SupplyOutputTermination StyleOutput TypeAccuracyOperating PressurePressure TypePort StylePort SizeMaximum PressureMax PressureRoHS StatusView Compare
-
PPT0500GXX2VA6 WeeksModule Cube-40°C~85°C2012Obsolete1 (Unlimited)Industrial Automation5.5V~30V0 V ~ 5 VConnectorAnalog, RS-232±0.05%500PSI (3447.38kPa)Vented GaugeThreadedFemale - 1/8" 3.18mm Swagelok? Dual600PSI (4136.85kPa)600 PSINon-RoHS Compliant-
-
11 Weeks---Active1 (Unlimited)------------Non-RoHS Compliant
-
11 WeeksModule Cube-40°C~85°C-Active1 (Unlimited)Industrial Automation5.5V~30V0 V ~ 5 VConnectorAnalog, RS-485±0.05%±1PSI (±6.89kPa)DifferentialBarbedMale - 0.13 3.18mm Tube Dual±3PSI (±20.68kPa)3 PSINon-RoHS Compliant
-
11 WeeksModule Cube-40°C~85°C2012Active1 (Unlimited)Industrial Automation5.5V~30V0 V ~ 5 VConnectorAnalog, RS-485±0.05%±1PSI (±6.89kPa)DifferentialFilteredFilter Dual±3PSI (±20.68kPa)3 PSINon-RoHS Compliant
Popular Search Part Number
Related Keywords
Search Tags
- P51-3000-S-Y-M12-5V-000-000
- P51-75-S-S-M12-5V-000-000
- P51-75-S-H-M12-5V-000-000
- P51-100-S-P-M12-4.5OVP-000-000
- P51-750-S-Y-M12-4.5OVP-000-000
- P51-1000-S-F-M12-4.5OVP-000-000
- P51-100-S-H-M12-4.5OVP-000-000
- P51-75-S-D-M12-4.5OVP-000-000
- P51-1500-S-A-M12-4.5OVP-000-000
- P51-1500-S-Y-M12-4.5V-000-000
- P51-100-S-S-M12-4.5V-000-000
- P51-3000-S-B-M12-4.5OVP-000-000
- P51-1500-S-H-M12-4.5V-000-000
- P51-1000-S-J-M12-4.5V-000-000
- P51-1500-S-B-M12-4.5V-000-000
Latest News
-
27 November 2023
BT151 SCR Features, Pin Configuration, Working Principle and Applications
Ⅰ. What is a one-way thyristor?Ⅱ. Overview of BT151Ⅲ. What are the features of BT151?Ⅳ. Footprint and pin configuration of BT151Ⅴ. Technical parameters of BT151Ⅵ. How to measure... -
28 November 2023
An Introduction to LM393 Low Power Dual Voltage Comparator
Ⅰ. What is LM393 comparator?Ⅱ. What are the features of LM393 comparator?Ⅲ. Pin configuration of LM393 comparatorⅣ. Functions of LM393 comparatorⅤ. Technical parameters of LM393 comparatorⅥ. Typical circuit... -
28 November 2023
Get to Know the TL494 Pulse-Width-Modulation Control Circuits
Ⅰ. Overview of TL494Ⅱ. What are the features of TL494?Ⅲ. TL494 symbol, footprint and pin configurationⅣ. Internal structure and working parts of TL494Ⅴ. How does the TL494 work?Ⅵ.... -
29 November 2023
TDA7293 Audio Power Amplifier: Symbol, Features, Applications and TDA7293 vs TDA8954
Ⅰ. Overview of TDA7293Ⅱ. Symbol, footprint and pin configuration of TDA7293Ⅲ. Features of TDA7293Ⅳ. Technical parameters of TDA7293Ⅴ. What are the applications of TDA7293?Ⅵ. What is the difference...
Help you to save your cost and time.
Reliable package for your goods.
Fast Reliable Delivery to save time.
Quality premium after-sale service.