MET-46

Tamura MET-46

Part Number:
MET-46
Manufacturer:
Tamura
Ventron No:
5027074-MET-46
Description:
TEL TRANS 600:600 3.0MADC
ECAD Model:
Datasheet:
MET-46

Quick Request Quote

Please send RFQ , We will respond immediately.

Part Number
Quantity
Company
E-mail
Phone
Comments
Specifications
Tamura MET-46 technical specifications, attributes, parameters and parts with similar specifications to Tamura MET-46.
  • Factory Lead Time
    25 Weeks
  • Mount
    Through Hole
  • Mounting Type
    Through Hole
  • Package / Case
    600
  • Number of Pins
    4
  • Operating Temperature
    -40°C~85°C
  • Packaging
    Bulk
  • Published
    2006
  • Series
    MET
  • Size / Dimension
    0.409Lx0.310W 10.40mmx7.87mm
  • Part Status
    Active
  • Moisture Sensitivity Level (MSL)
    1 (Unlimited)
  • Termination
    PC Pin
  • Max Operating Temperature
    85°C
  • Min Operating Temperature
    -40°C
  • Power Rating
    50mW
  • Frequency
    100kHz
  • Termination Style
    PC Pin
  • Voltage - Isolation
    1500VRMS @ 1 Minute
  • DC Resistance (DCR)
    72Ohm
  • Current
    3mA
  • Frequency Range
    300Hz~3.5kHz
  • Transformer Type
    Data/Voice Coupling
  • Turns Ratio - Primary:Secondary
    1:1
  • Impedance - Primary (Ω)
    600
  • Frequency Response
    ±1dB
  • Impedance - Secondary (Ω)
    600
  • DC Resistance (DCR) - Primary
    85Ohm
  • DC Resistance (DCR) - Secondary
    110Ohm
  • Power Level
    50mW
  • Height
    11.8mm
  • Height Seated (Max)
    0.465 11.80mm
  • Length
    10.4mm
  • Width
    7.87mm
  • RoHS Status
    RoHS Compliant
  • Lead Free
    Contains Lead
Description
part No. MET-46 Is this available? : YesShipped from : HK warehouseSame model may have different manufacturers, images only for reference.
MET-46 More Descriptions
Audio Transformer 1:1 1000Vrms 72Ohm Prim. DCR 93Ohm Sec. DCR 4 Terminal PC Pin Thru-Hole
EMCH-TRANSFORMERS-AUDIO, TELEPHONE COUPLING
Audio Transformers 600 Pri./600 Sec.
HALL EFFECT VOLTAGE TRANSDUCER
Product Comparison
The three parts on the right have similar specifications to MET-46.
  • Image
    Part Number
    Manufacturer
    Factory Lead Time
    Mount
    Mounting Type
    Package / Case
    Number of Pins
    Operating Temperature
    Packaging
    Published
    Series
    Size / Dimension
    Part Status
    Moisture Sensitivity Level (MSL)
    Termination
    Max Operating Temperature
    Min Operating Temperature
    Power Rating
    Frequency
    Termination Style
    Voltage - Isolation
    DC Resistance (DCR)
    Current
    Frequency Range
    Transformer Type
    Turns Ratio - Primary:Secondary
    Impedance - Primary (Ω)
    Frequency Response
    Impedance - Secondary (Ω)
    DC Resistance (DCR) - Primary
    DC Resistance (DCR) - Secondary
    Power Level
    Height
    Height Seated (Max)
    Length
    Width
    RoHS Status
    Lead Free
    ECCN Code
    Current Rating
    Resistance
    Reach Compliance Code
    Max DC Current
    View Compare
  • MET-46
    MET-46
    25 Weeks
    Through Hole
    Through Hole
    600
    4
    -40°C~85°C
    Bulk
    2006
    MET
    0.409Lx0.310W 10.40mmx7.87mm
    Active
    1 (Unlimited)
    PC Pin
    85°C
    -40°C
    50mW
    100kHz
    PC Pin
    1500VRMS @ 1 Minute
    72Ohm
    3mA
    300Hz~3.5kHz
    Data/Voice Coupling
    1:1
    600
    ±1dB
    600
    85Ohm
    110Ohm
    50mW
    11.8mm
    0.465 11.80mm
    10.4mm
    7.87mm
    RoHS Compliant
    Contains Lead
    -
    -
    -
    -
    -
    -
  • MET-36
    25 Weeks
    Through Hole
    Through Hole
    600
    5
    -20°C~85°C
    Bulk
    1999
    MET
    0.409Lx0.310W 10.40mmx7.87mm
    Active
    1 (Unlimited)
    PC Pin
    -
    -
    -
    -
    PC Pin
    500VRMS @ 30 Seconds
    -
    -
    300Hz~100kHz
    GENERAL PURPOSE AUDIO TRANSFORMER
    13.7:1
    600CT
    ±2dB
    3.2
    60Ohm
    700mOhm
    50mW
    11.8mm
    0.465 11.80mm
    -
    -
    RoHS Compliant
    -
    EAR99
    4.5mA
    -
    -
    -
  • MET-45
    25 Weeks
    Through Hole
    Through Hole
    -
    6
    -20°C~85°C
    Bulk
    1999
    MET
    0.409Lx0.310W 10.40mmx7.87mm
    Active
    1 (Unlimited)
    PC Pin
    -
    -
    -
    20kHz
    PC Pin
    500VRMS @ 30 Seconds
    1.3kOhm
    1mA
    300Hz~20kHz
    Data/Voice Coupling
    1:0.5
    10k
    ±3dB
    10k 2.5k/2.5k
    1.3kOhm
    735Ohm~390Ohm 850Ohm~455Ohm
    75mW
    11.8mm
    0.465 11.80mm
    -
    -
    RoHS Compliant
    Lead Free
    EAR99
    -
    2.5kOhm
    unknown
    -
  • MET-37
    25 Weeks
    Through Hole
    Through Hole
    -
    5
    -20°C~85°C
    Bulk
    1999
    MET
    0.409Lx0.310W 10.40mmx7.87mm
    Active
    1 (Unlimited)
    PC Pin
    -
    -
    50mW
    100kHz
    PC Pin
    500VRMS @ 30 Seconds
    95Ohm
    -
    300Hz~100kHz
    GENERAL PURPOSE
    0.918:1
    500CT
    ±2dB
    600
    65Ohm
    95Ohm
    -
    11.8mm
    0.465 11.80mm
    -
    -
    RoHS Compliant
    -
    EAR99
    3mA
    600Ohm
    -
    3mA
Certification
  • ISO 9001
  • ISO 13485
  • ISO 45001
  • ASA
  • ESD
  • DUNS
  • SMTA
  • ROHS

Latest News

  • 08 March 2024

    In-depth Analysis of SS34 Schottky Diode

    Ⅰ. Overview of SS34Ⅱ. Purpose of SS34 diodeⅢ. Technical parameters of SS34 diodeⅣ. Advantages of SS34 diodesⅤ. Working principle of SS34 diodeⅥ. Typical characteristics of SS34 diodesⅦ. Case...
  • 11 March 2024

    BTS50085-1TMA Specifications, Functions, Purpose and More

    Ⅰ. What is BTS50085-1TMA?Ⅱ. Specifications of BTS50085-1TMAⅢ. What are the functions of BTS50085-1TMA?Ⅳ. Inverse load current operation of BTS50085-1TMAⅤ. Externally adjustable current limit of BTS50085-1TMAⅥ. How to use...
  • 11 March 2024

    LM317: Ideal for Adjustable, High-Efficiency Three-Terminal Regulators

    Ⅰ. Introduction to LM317Ⅱ. The function of LM317 adjustable voltage stabilized power supply voltage stabilizing circuitⅢ. Soft-start circuit of LM317Ⅳ. Minimum stable operating current of LM317Ⅴ. Calculation of...
  • 12 March 2024

    MPU-6050 Manufacturer, Working Principle, Application and Package

    Ⅰ. Introduction to MPU-6050Ⅱ. Manufacturer of MPU-6050Ⅲ. Internal block diagram of MPU-6050Ⅳ. How does the MPU-6050 work?Ⅴ. Where is MPU-6050 used?Ⅵ. Package of MPU-6050Ⅶ. How to reduce the...
  • cost

    Help you to save your cost and time.

  • package

    Reliable package for your goods.

  • fast

    Fast Reliable Delivery to save time.

  • service