0 Shopping Cart

XP Power JCM3024S05

Part Number:

JCM3024S05

Manufacturer:

XP Power

Ventron No:

5042991-JCM3024S05

Description:

DC-DC, 30W, SINGLE OUTPUT, 2:1,

ECAD Model:

Datasheet:

JCM3024S05

Payment:

Payment

Delivery:

Delivery

Quick Request Quote

Please send RFQ , We will respond immediately.

Part Number
Quantity
Company
E-mail
Phone
Comments
  • One Stop Service

    One Stop Service

  • Competitive Price

    Competitive Price

  • Source Traceability

    Source Traceability

  • Same Day Delivery

    Same Day Delivery

Specifications

XP Power JCM3024S05 technical specifications, attributes, parameters and parts with similar specifications to XP Power JCM3024S05.

  • Factory Lead Time
    10 Weeks
  • Mount
    Through Hole
  • Mounting Type

    Mounting Type refers to the method by which an electronic component is attached to a printed circuit board (PCB) or other surface. Common mounting types include: * Through-hole: Component leads are inserted into holes in the PCB and soldered on the other side. * Surface-mount: Component is placed on the surface of the PCB and soldered in place. * Press-fit: Component is pressed into place on the PCB without soldering. * Socket: Component is inserted into a socket on the PCB, allowing for easy replacement. The mounting type is determined by factors such as the component's size, shape, and power requirements.

    Through Hole
  • Package / Case

    Package / Case refers to the physical housing or enclosure that encapsulates an electronic component. It provides protection, facilitates handling, and enables electrical connections. The package type determines the component's size, shape, pin configuration, and mounting options. Common package types include DIP (dual in-line package), SOIC (small outline integrated circuit), and BGA (ball grid array). The package also influences the component's thermal and electrical performance.

    6-DIP Module
  • Operating Temperature

    Operating Temperature is the range of temperatures at which an electronic component can function properly. It is typically specified in degrees Celsius (°C) and indicates the minimum and maximum temperatures at which the component can operate without experiencing damage or degradation. Operating Temperature is an important parameter to consider when designing electronic circuits, as it ensures that the components will function reliably in the intended operating environment.

    -40°C~100°C
  • Packaging
    Tube
  • Series

    Series, in the context of electronic components, refers to the arrangement of components in a circuit. When components are connected in series, they form a single path for current to flow through. The total resistance of a series circuit is the sum of the individual resistances of each component. Series connections are often used to control the flow of current in a circuit, as the total resistance can be adjusted by changing the number or type of components in the series.

    JCM30 (30W)
  • Published
    2016
  • Size / Dimension
    1.00Lx1.00W x 0.41 H 25.4mmx25.4mmx10.4mm
  • Feature
    Remote On/Off, OVP, SCP
  • Pbfree Code
    yes
  • Part Status

    Part Status is an electronic component parameter that indicates the availability and production status of a component. It is typically used to inform customers about the availability of a component, whether it is in production, end-of-life, or obsolete. Part Status can also provide information about any restrictions or limitations on the component's use, such as whether it is only available for certain applications or if it has been discontinued.

    Active
  • Moisture Sensitivity Level (MSL)

    Moisture Sensitivity Level (MSL) is a measure of the susceptibility of a surface mount electronic component to moisture-induced damage during soldering. It is classified into six levels, from 1 (least sensitive) to 6 (most sensitive). MSL is determined by the materials used in the component's construction, including the solderability of its terminals and the presence of moisture-absorbing materials. Components with higher MSL ratings require more stringent handling and storage conditions to prevent moisture absorption and subsequent damage during soldering.

    1 (Unlimited)
  • ECCN Code
    EAR99
  • Applications
    ITE (Commercial)
  • Max Power Dissipation
    30W
  • Peak Reflow Temperature (Cel)
    NOT SPECIFIED
  • Depth
    25.4mm
  • Time@Peak Reflow Temperature-Max (s)
    NOT SPECIFIED
  • Number of Outputs

    Number of Outputs refers to the number of independent output signals or channels that an electronic component can provide. It indicates the capability of the component to drive multiple external devices or circuits simultaneously. A higher number of outputs allows for greater flexibility and connectivity in electronic systems.

    1
  • Efficiency
    90%
  • Voltage - Isolation

    Voltage - Isolation refers to the maximum voltage that can be applied between two points in an electronic component without causing electrical breakdown. It is a measure of the component's ability to withstand high voltages without allowing current to flow between the points. A higher voltage isolation rating indicates that the component can withstand higher voltages without failing.

    1.6kV
  • Voltage - Input (Max)
    36V
  • Max Output Current
    6A
  • Voltage - Output 1
    5V
  • Output Power

    Output Power is a measure of the electrical power delivered by an electronic component to a load. It is typically expressed in watts (W) or milliwatts (mW). The output power of a component is determined by its design and the voltage and current applied to it. Output power is an important parameter for many electronic components, such as amplifiers, power supplies, and transmitters. It is used to determine the component's efficiency and to ensure that it can provide enough power to drive the load.

    30W
  • Control Features
    Enable, Active High
  • Current - Output 1
    6A
  • Max Output Power
    30W
  • Max Input Voltage (DC)
    36V
  • Min Input Voltage (DC)
    18V
  • Height

    Height, in the context of electronic components, refers to the vertical dimension of the component. It is typically measured in millimeters (mm) or inches (in). Height is an important parameter to consider when designing and assembling electronic circuits, as it affects the overall size and form factor of the device. Components with a smaller height are often preferred for applications where space is limited, such as in portable devices or embedded systems.

    10.414mm
  • REACH SVHC
    No SVHC
  • RoHS Status
    ROHS3 Compliant

Description

part#JCM3024S05, Manufacturer:XP Power is available at ventronchip.com, see description of JCM3024S05 as below .use the request quote form to request JCM3024S05 price and lead time.Every pieces of Electronic Components you buy from ventronchip.com is warranty and quality guaranted.we are an independent distributor of electronic components with extensive inventory in stock.The price and lead time for JCM3024S05 depending on the quantity required, availability and warehouse location.
JCM3024S05 More Descriptions
DC-DC Converter, Thru Hole, DIP, 30W, 5V@6A, 18-36V In, JCM30 Series | XP Power JCM3024S05
DC-DC Regulated Power Supply Module, 1 Output, 30W, Hybrid
Dc-Dc Converter, 5V, 6A; No. Of Outputs:1 Output; Output Power Max:30W; Output Voltage - Output 1:5V; Output Current - Output 1:6A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage - Output 3:-; Output Currentrohs Compliant: Yes |Xp Power JCM3024S05
CoC and 2-years warranty / RFQ for pricing
DC-DC, 30W, SINGLE OUTPUT, 2:1,

Product Comparison

The three parts on the right have similar specifications to JCM3024S05.
  • Image
    Part Number
    Manufacturer
    Factory Lead Time
    Mount
    Mounting Type
    Package / Case
    Operating Temperature
    Packaging
    Series
    Published
    Size / Dimension
    Feature
    Pbfree Code
    Part Status
    Moisture Sensitivity Level (MSL)
    ECCN Code
    Applications
    Max Power Dissipation
    Peak Reflow Temperature (Cel)
    Depth
    Time@Peak Reflow Temperature-Max (s)
    Number of Outputs
    Efficiency
    Voltage - Isolation
    Voltage - Input (Max)
    Max Output Current
    Voltage - Output 1
    Output Power
    Control Features
    Current - Output 1
    Max Output Power
    Max Input Voltage (DC)
    Min Input Voltage (DC)
    Height
    REACH SVHC
    RoHS Status
    View Compare
  • JCM3024S05
    JCM3024S05
    10 Weeks
    Through Hole
    Through Hole
    6-DIP Module
    -40°C~100°C
    Tube
    JCM30 (30W)
    2016
    1.00Lx1.00W x 0.41 H 25.4mmx25.4mmx10.4mm
    Remote On/Off, OVP, SCP
    yes
    Active
    1 (Unlimited)
    EAR99
    ITE (Commercial)
    30W
    NOT SPECIFIED
    25.4mm
    NOT SPECIFIED
    1
    90%
    1.6kV
    36V
    6A
    5V
    30W
    Enable, Active High
    6A
    30W
    36V
    18V
    10.414mm
    No SVHC
    ROHS3 Compliant
    -
  • JCM3024S3V3
    10 Weeks
    Through Hole
    Through Hole
    6-DIP Module
    -40°C~100°C
    Tube
    JCM30 (30W)
    2016
    1.00Lx1.00W x 0.41 H 25.4mmx25.4mmx10.4mm
    Remote On/Off, OVP, SCP
    yes
    Active
    1 (Unlimited)
    EAR99
    ITE (Commercial)
    23W
    NOT SPECIFIED
    25.4mm
    NOT SPECIFIED
    1
    87%
    1.6kV
    36V
    7A
    3.3V
    30W
    Enable, Active High
    7A
    30W
    36V
    18V
    10.414mm
    No SVHC
    ROHS3 Compliant
  • JCM3012S05
    10 Weeks
    Through Hole
    Through Hole
    6-DIP Module
    -40°C~100°C
    Tube
    JCM30 (30W)
    2016
    1.00Lx1.00W x 0.41 H 25.4mmx25.4mmx10.4mm
    Remote On/Off, OVP, SCP
    yes
    Active
    1 (Unlimited)
    EAR99
    ITE (Commercial)
    30W
    NOT SPECIFIED
    25.4mm
    NOT SPECIFIED
    1
    89%
    1.6kV
    18V
    6A
    5V
    30W
    Enable, Active High
    6A
    30W
    18V
    9V
    10.414mm
    No SVHC
    ROHS3 Compliant
  • JCM3048S15
    10 Weeks
    Through Hole
    Through Hole
    6-DIP Module
    -40°C~100°C
    Tube
    JCM30 (30W)
    2016
    1.00Lx1.00W x 0.41 H 25.4mmx25.4mmx10.4mm
    Remote On/Off, OVP, SCP
    yes
    Active
    1 (Unlimited)
    EAR99
    ITE (Commercial)
    30W
    NOT SPECIFIED
    25.4mm
    NOT SPECIFIED
    1
    91%
    1.6kV
    75V
    2A
    15V
    30W
    Enable, Active High
    2A
    30W
    75V
    36V
    10.414mm
    No SVHC
    ROHS3 Compliant