Schaffner EMC Inc. FN2410-100-34
- Part Number:
- FN2410-100-34
- Manufacturer:
- Schaffner EMC Inc.
- Ventron No:
- 3599109-FN2410-100-34
- Description:
- LINE FILTER 250VAC 100A CHASS
- Datasheet:
- FN2410-100-34
Schaffner EMC Inc. FN2410-100-34 technical specifications, attributes, parameters and parts with similar specifications to Schaffner EMC Inc. FN2410-100-34.
- Factory Lead Time10 Weeks
- MountChassis, Chassis Mount
- Mounting TypeChassis Mount
- Package / Case100
- Operating Temperature-25°C~100°C
- PackagingTray
- Published2005
- SeriesFN 2410
- Pbfree Codeyes
- Part StatusActive
- Moisture Sensitivity Level (MSL)Not Applicable
- TerminationTerminal Block
- ApplicationsGeneral Purpose
- Voltage - Rated DC250V
- Depth115mm
- Current Rating100A
- Frequency400Hz
- Termination StyleTerminal Block
- Voltage - Rated AC250V
- Approval AgencyCSA, ENEC, UR
- ConfigurationSingle Stage
- Leakage Current3.4mA
- Max Voltage Rating (AC)250V
- Max Current Rating100A
- Wire/Cable Gauge2 AWG
- Filter TypeSingle Phase
- Frequency - OperatingDC~400Hz
- Height165mm
- Length115mm
- Width115mm
- Radiation HardeningNo
- RoHS StatusRoHS Compliant
- RatingsIP20
part#FN2410-100-34, Manufacturer:Schaffner EMC, Inc. is available at ventronchip.com, see description of FN2410-100-34 as below .use the request quote form to request FN2410-100-34 price and lead time.Every pieces of Electronic Components you buy from ventronchip.com is warranty and quality guaranted.we are an independent distributor of electronic components with extensive inventory in stock.The price and lead time for FN2410-100-34 depending on the quantity required, availability and warehouse location.
FN2410-100-34 More Descriptions
Power Line Filter 0Hz to 400Hz 100A 250VAC Terminal Block DIN Rail
FILTER, 100A, SINGLE PHASE; Voltage rating, AC:250V; Current rating:100A; Phases, No. of:1; Length / Height, external:165mm; Width, external:115mm; Depth, external:100mm; Temp, op. max:100°C; Temp, op. min:-25°C
Rfi Power Line Filter, 100A, 3.4Ma; Filter Applications:General Purpose; Voltage Rating:250Vac; Current Rating:100A; No. Of Phases:Single Phase; No. Of Stages:1 Stage; Filter Input Terminals:Terminal Block; Depth:100Mm; Height:165Mm Rohs Compliant: Yes |Schaffner FN2410-100-34
FILTER, 100A, SINGLE PHASE; Voltage rating, AC:250V; Current rating:100A; Phases, No. of:1; Length / Height, external:165mm; Width, external:115mm; Depth, external:100mm; Temp, op. max:100°C; Temp, op. min:-25°C
Rfi Power Line Filter, 100A, 3.4Ma; Filter Applications:General Purpose; Voltage Rating:250Vac; Current Rating:100A; No. Of Phases:Single Phase; No. Of Stages:1 Stage; Filter Input Terminals:Terminal Block; Depth:100Mm; Height:165Mm Rohs Compliant: Yes |Schaffner FN2410-100-34
The three parts on the right have similar specifications to FN2410-100-34.
-
ImagePart NumberManufacturerFactory Lead TimeMountMounting TypePackage / CaseOperating TemperaturePackagingPublishedSeriesPbfree CodePart StatusMoisture Sensitivity Level (MSL)TerminationApplicationsVoltage - Rated DCDepthCurrent RatingFrequencyTermination StyleVoltage - Rated ACApproval AgencyConfigurationLeakage CurrentMax Voltage Rating (AC)Max Current RatingWire/Cable GaugeFilter TypeFrequency - OperatingHeightLengthWidthRadiation HardeningRoHS StatusRatingsPhysical DimensionREACH SVHCHigh PotWeightLeakage Current (Max)View Compare
-
FN2410-100-3410 WeeksChassis, Chassis MountChassis Mount100-25°C~100°CTray2005FN 2410yesActiveNot ApplicableTerminal BlockGeneral Purpose250V115mm100A400HzTerminal Block250VCSA, ENEC, URSingle Stage3.4mA250V100A2 AWGSingle PhaseDC~400Hz165mm115mm115mmNoRoHS CompliantIP20------
-
10 WeeksDIN RailDIN Rail300-25°C~100°CTray2008FN 2412yesActive1 (Unlimited)Terminal BlockRegenerative Motor Drive250V93mm8A400HzTerminal Block520V 300VCSA, ENEC, URSingle Stage3.4mA520V8A-Single PhaseDC~400Hz73mm154mm-NoRoHS Compliant-L110.0XB93.0XH73.0 (mm)/L4.331XB3.661XH2.874 (inch)No SVHC---
-
10 WeeksDIN RailDIN Rail300-25°C~100°CTray2008FN 2412yesActive1 (Unlimited)Terminal BlockRegenerative Motor Drive300V93mm25A400HzTerminal Block520V 300VCSA, ENEC, URSingle Stage3.4mA520V25A-Single PhaseDC~400Hz87mm160mm-NoRoHS Compliant-L110.0XB93.0XH87.0 (mm)/L4.331XB3.661XH3.425 (inch)No SVHC2250 V--
-
10 WeeksChassis, Chassis Mount, FlangesChassis Mount--25°C~100°CTray2008FN 2415yesNot For New Designs1 (Unlimited)Terminal BlockGeneral Purpose-56mm16A60HzTerminal Block250VCSA, ENEC, URTwo Stage-250V16A-Single PhaseDC~60Hz45.4mm94mm58mmNoRoHS CompliantIP20L94.0XB56.0XH45.4 (mm)/L3.701XB2.205XH1.787 (inch)-1100 V400g9.4mA
Popular Search Part Number
Related Keywords
Search Tags
Latest News
-
13 October 2023
Universal Logic Gate Chip SN7406N: Equivalent, Working Principle and Package
Ⅰ. What is SN7406N?Ⅱ. Symbol, footprint and pinout of SN7406NⅢ. Technical parameters of SN7406NⅣ. Features of SN7406NⅤ. Working principle of SN7406NⅥ. Dimensions and package of SN7406NⅦ. Manufacturer of... -
13 October 2023
LM3481MM NOPB Converter Features, Pin Configuraiton and Other Details
Ⅰ. Overview of LM3481MM/NOPBⅡ. Symbol and footprint of LM3481MM/NOPBⅢ. Technical parameters of LM3481MM/NOPBⅣ. Features of LM3481MM/NOPBⅤ. Pin configuration of LM3481MM/NOPBⅥ. Application of LM3481MM/NOPBⅦ. How to improve the efficiency... -
16 October 2023
What Is H1102N Pulse Ethernet Transformer?
Ⅰ. What is a transformer?Ⅱ. Overview of H1102NLⅢ. Pin configuration, symbol and footprint of H1102NLⅣ. Technical parameters of H1102NLⅤ. Features of H1102NLⅥ. Working principle of H1102NLⅦ. Dimensions and... -
16 October 2023
BD139 Transistor Equivalent, Technical Parameters and Applications
Ⅰ. Overview of BD139Ⅱ. BD139 symbol, footprint and pin configurationⅢ. Technical parameters of BD139Ⅳ. Features of BD139Ⅴ. Working principle of BD139 transistorⅥ. Circuit of BD139 transistor power amplifierⅦ....
Help you to save your cost and time.
Reliable package for your goods.
Fast Reliable Delivery to save time.
Quality premium after-sale service.