Fluke Electronics FLUKE-1507
- Part Number:
- FLUKE-1507
- Manufacturer:
- Fluke Electronics
- Ventron No:
- 5111826-FLUKE-1507
- Description:
- TSTER INSUL RESITNCE 0.01M-10G
- Datasheet:
- Test Tool Catalog
Fluke Electronics FLUKE-1507 technical specifications, attributes, parameters and parts with similar specifications to Fluke Electronics FLUKE-1507.
- Factory Lead Time8 Weeks
- Weight550g
- PackagingBulk
- Series1507
- Published2005
- Part StatusActive
- Moisture Sensitivity Level (MSL)1 (Unlimited)
- Max Operating Temperature55°C
- Min Operating Temperature-20°C
- Current Rating1mA
- Test Current200mA
- Tool TypeMegohmmeter
- Display TypeLCD
- Height50.03mm
- Length203mm
- Width100mm
- REACH SVHCNo SVHC
- RoHS StatusNon-RoHS Compliant
- Lead FreeLead Free
Images are for reference only.See Product Specifications for product details.If you are interested to buy Fluke Electronics FLUKE-1507.
FLUKE-1507 More Descriptions
Insulation Resistance Tester 0.01M - 10G 50/100/250/500/1000 V Digital Backlit LCD Display
TESTER,INSULATION,50V,100V,250V,500V,1KV; Insulation Tester Type: Digital Megohmmeter; Insulation Testing Voltage: 50V, 100V, 250V, 500V, 1kV; Insulation Testing Resistance: 10kohm to 10Gohm; Operating Temperature Min: -20°C
Insulation Tester (Megohmmeter); Insulation Test Voltage:50V, 100V, 250V, 500V, 1000V; Continuity Test Range:0.01MOhm to 10GOhms; Resistance Measuring Range:0.01 MOhm to 10 GOhm; Voltage Measuring Range AC:0.1V to 600V ;RoHS Compliant: NA
Tester Type = Insulation & Resistance Tester / Insulation Resistance Min. MOhm = 0.01 / Insulation Resistance Max. GOhm = 10 / Insulation Resistance Accuracy = ±1.5 % / Other Measuring Ranges = Earth Bond Resistance Measurement: 20 Ohm ... 20 kOhm / Test Voltage kV = 1 / Short Circuit Current mA = 1 / Display Type = LCD / Safety Category = CAT IV 600 V / Protection Rating = IP40 / Measuring Functions = AC/DC Voltage / Measuring Functions = Auto-Discharge / Measuring Functions = Resistance / Measuring Functions = Continuity
Combines an insulation tester with basic DMM functionality. Test motors, cables, appliances and electrical installations. Testing is inhibited if the circuit is live, and automatically discharges after testing for operator safety. Supplied with a push-button probe, so that you can test without holding the meter. Lock down & Lead null buttons. Rugged construction with large backlit display that shows information at a glance. Cat IV-600V safety rating means that it is suitable for all uses and areas. Measures ac/dc volts, resistance & continuity using a 200mA test current. Model 1507 has advanced features that test over time for moisture ingress & insulation breakdown. Model 1503 Test voltages 500/1000V Insulation measurement range: 0.01 M to 2000 M Model 1507 Test voltages: 50/100/250/500/1000V Insulation measurement range: 0.01 M to 10 G Measure Dielectric Absorption & Polarisation Index Contents: Remote test probe, Test Leads, Test Probes, Alligator clips, Manual TPAK - Magnetic/Velcro hanging kit. Fluke TPAK is compatible with all current Fluke DMM's (plus the 1503 & 1507). Hang your DMM on panels, hooks & pipework for convenience & added safety.
TESTER,INSULATION,50V,100V,250V,500V,1KV; Insulation Tester Type: Digital Megohmmeter; Insulation Testing Voltage: 50V, 100V, 250V, 500V, 1kV; Insulation Testing Resistance: 10kohm to 10Gohm; Operating Temperature Min: -20°C
Insulation Tester (Megohmmeter); Insulation Test Voltage:50V, 100V, 250V, 500V, 1000V; Continuity Test Range:0.01MOhm to 10GOhms; Resistance Measuring Range:0.01 MOhm to 10 GOhm; Voltage Measuring Range AC:0.1V to 600V ;RoHS Compliant: NA
Tester Type = Insulation & Resistance Tester / Insulation Resistance Min. MOhm = 0.01 / Insulation Resistance Max. GOhm = 10 / Insulation Resistance Accuracy = ±1.5 % / Other Measuring Ranges = Earth Bond Resistance Measurement: 20 Ohm ... 20 kOhm / Test Voltage kV = 1 / Short Circuit Current mA = 1 / Display Type = LCD / Safety Category = CAT IV 600 V / Protection Rating = IP40 / Measuring Functions = AC/DC Voltage / Measuring Functions = Auto-Discharge / Measuring Functions = Resistance / Measuring Functions = Continuity
Combines an insulation tester with basic DMM functionality. Test motors, cables, appliances and electrical installations. Testing is inhibited if the circuit is live, and automatically discharges after testing for operator safety. Supplied with a push-button probe, so that you can test without holding the meter. Lock down & Lead null buttons. Rugged construction with large backlit display that shows information at a glance. Cat IV-600V safety rating means that it is suitable for all uses and areas. Measures ac/dc volts, resistance & continuity using a 200mA test current. Model 1507 has advanced features that test over time for moisture ingress & insulation breakdown. Model 1503 Test voltages 500/1000V Insulation measurement range: 0.01 M to 2000 M Model 1507 Test voltages: 50/100/250/500/1000V Insulation measurement range: 0.01 M to 10 G Measure Dielectric Absorption & Polarisation Index Contents: Remote test probe, Test Leads, Test Probes, Alligator clips, Manual TPAK - Magnetic/Velcro hanging kit. Fluke TPAK is compatible with all current Fluke DMM's (plus the 1503 & 1507). Hang your DMM on panels, hooks & pipework for convenience & added safety.
The three parts on the right have similar specifications to FLUKE-1507.
-
ImagePart NumberManufacturerFactory Lead TimeWeightPackagingSeriesPublishedPart StatusMoisture Sensitivity Level (MSL)Max Operating TemperatureMin Operating TemperatureCurrent RatingTest CurrentTool TypeDisplay TypeHeightLengthWidthREACH SVHCRoHS StatusLead FreeView Compare
-
FLUKE-15078 Weeks550gBulk15072005Active1 (Unlimited)55°C-20°C1mA200mAMegohmmeterLCD50.03mm203mm100mmNo SVHCNon-RoHS CompliantLead Free-
-
8 Weeks----Active1 (Unlimited)----Insulation Resistance Tester-----RoHS Compliant-
-
8 Weeks--Fluke Connect™-Active1 (Unlimited)----Power Quality and Energy Analyzer-----RoHS Compliant-
-
8 Weeks--MDA-500-ActiveNot Applicable----Motor Drive Analyzer-----RoHS Compliant-
Popular Search Part Number
Related Keywords
Search Tags
Latest News
-
10 April 2024
STM32F103CBT6 Microcontroller Features, Application and STM32F103CBT6 vs CKS32F103C8T6
Ⅰ. Description of STM32F103CBT6Ⅱ. Low-power modes of STM32F103CBT6Ⅲ. Functional features of STM32F103CBT6Ⅳ. Application fields of STM32F103CBT6Ⅴ. GPIO attributes and configuration process of STM32F103CBT6Ⅵ. How to program and debug... -
11 April 2024
A Complete Guide to IR2104 Half-Bridge Driver
Ⅰ. IR2104 descriptionⅡ. IR2104 half-bridge driver circuit characteristicsⅢ. IR2104 half-bridge driver working principleⅣ. Practical application of IR2104Ⅴ. Recommended operating conditions of IR2104Ⅵ. What are the heat dissipation measures... -
11 April 2024
74LS138 Decoder Working Principle, Application Scenarios and 7AHC138 vs 74LS138
Ⅰ. Introduction to 74LS138Ⅱ. What is the meaning of the 74LS138 naming?Ⅲ. Working principle of 74LS138Ⅳ. Example of application circuit diagram of 74LS138Ⅴ. Application scenarios of 74LS138 decoderⅥ.... -
12 April 2024
L298N DC Motor Drive Module: Features, Pinout, Usage and Application
Ⅰ. Introduction to L298NⅡ. Functional features of L298NⅢ. L298N circuit diagramⅣ. Control method of L298NⅤ. Pin diagram and functions of L298NⅥ. How to use L298N?Ⅶ. How to use...
Help you to save your cost and time.
Reliable package for your goods.
Fast Reliable Delivery to save time.
Quality premium after-sale service.