0 Shopping Cart

Omron Electronics Inc-EMC Div D6F-CABLE2

Part Number:

D6F-CABLE2

Manufacturer:

Omron Electronics Inc-EMC Div

Ventron No:

4411890-D6F-CABLE2

Description:

CABLE FOR D6F MASSFLOW SENSOR

Datasheet:

D6F-CABLE2

Payment:

Payment

Delivery:

Delivery

Quick Request Quote

Please send RFQ , We will respond immediately.

Part Number
Quantity
Company
E-mail
Phone
Comments
  • One Stop Service

    One Stop Service

  • Competitive Price

    Competitive Price

  • Source Traceability

    Source Traceability

  • Same Day Delivery

    Same Day Delivery

Specifications

Omron Electronics Inc-EMC Div D6F-CABLE2 technical specifications, attributes, parameters and parts with similar specifications to Omron Electronics Inc-EMC Div D6F-CABLE2.

  • Factory Lead Time
    7 Weeks
  • Number of Pins

    Number of Pins: Indicates the number of electrical connections available on the component. These pins are used to connect the component to other components or circuits on a printed circuit board (PCB). The number of pins determines the functionality and connectivity options of the component. It is important to ensure that the component has the correct number of pins for the intended application.

    3
  • Published
    2004
  • Series

    Series, in the context of electronic components, refers to the arrangement of components in a circuit. When components are connected in series, they form a single path for current to flow through. The total resistance of a series circuit is the sum of the individual resistances of each component. Series connections are often used to control the flow of current in a circuit, as the total resistance can be adjusted by changing the number or type of components in the series.

    D6F
  • Part Status

    Part Status is an electronic component parameter that indicates the availability and production status of a component. It is typically used to inform customers about the availability of a component, whether it is in production, end-of-life, or obsolete. Part Status can also provide information about any restrictions or limitations on the component's use, such as whether it is only available for certain applications or if it has been discontinued.

    Active
  • Moisture Sensitivity Level (MSL)

    Moisture Sensitivity Level (MSL) is a measure of the susceptibility of a surface mount electronic component to moisture-induced damage during soldering. It is classified into six levels, from 1 (least sensitive) to 6 (most sensitive). MSL is determined by the materials used in the component's construction, including the solderability of its terminals and the presence of moisture-absorbing materials. Components with higher MSL ratings require more stringent handling and storage conditions to prevent moisture absorption and subsequent damage during soldering.

    Not Applicable
  • Gender
    Female
  • Number of Conductors
    4
  • Output Voltage

    Output Voltage is the voltage level produced by an electronic component when it is operating. It is typically measured in volts (V) and can be either positive or negative. The output voltage of a component is determined by its design and the input voltage applied to it. For example, a voltage regulator will produce a fixed output voltage regardless of the input voltage, while an amplifier will produce an output voltage that is proportional to the input voltage.

    5V
  • Lead Length

    Lead length refers to the distance between the body of an electronic component and the point where its leads or terminals emerge. It is a crucial parameter that affects the component's performance, reliability, and ease of assembly. Lead length influences factors such as inductance, capacitance, and heat dissipation. Longer leads can increase inductance and capacitance, which may impact signal integrity and circuit performance. They can also affect heat dissipation, as longer leads provide a larger surface area for heat transfer. Optimal lead length is determined based on the component's intended application and the desired electrical and thermal characteristics.

    200mm
  • Cable Length
    200mm
  • Accessory Type
    Cable
  • Wire/Cable Gauge
    30 AWG
  • Connector Type A
    Receptacle
  • Radiation Hardening
    No
  • REACH SVHC
    Unknown
  • RoHS Status
    RoHS Compliant
  • Ratings
    IP67

Description

D6F-CABLE2 Overview
The D6F series product, published in 2004, has 3 pins and a moisture sensitivity level of Not Applicable. It is a female connector with 4 conductors and a lead length of 200mm. The cable length is also 200mm and the connector type A is a receptacle. This product has a rating of IP67.

D6F-CABLE2 Features
Moisture Sensitivity Level (MSL): Not Applicable
D6F Series
3 Pins


D6F-CABLE2 Applications
There are a lot of Omron Electronics Inc-EMC Div
D6F-CABLE2 Accessories applications.


Aerospace equipment
Undersea equipment
Power plant control equipment
Medical equipment
Transportation equipment (vehicles, trans, ships, etc.)
Traffic signal equipment
Disaster prevention I crime prevention equipment
Data-processing equipment
Sensing tiny moving objects
Detecting a passing glass
D6F-CABLE2 More Descriptions
Cable connector assembly for D6F-P0010A2 | Omron Electronic Components D6F-CABLE2
CABLE FOR D6F03A3000; Connector to Connector: MEMS Flow Sensor Receptacle to Free End; Cable Length - Metric: 200mm; Cable Length - Imperial: 7.87"; Product Range: -; SVHC: No SVHC (27-Jun-2018); Accessory Type: Sensor connect
Sensor Cable, D6F03A3000, Wire To Board 3 Position Receptacle, Free/Stripped End, 200 Mm, 7.87 " Rohs Compliant: Yes |Omron Electronic Components D6F-CABLE2

Certification

  • ISO 9001
  • ISO 13485
  • ISO 45001
  • ASA
  • ESD
  • DUNS
  • SMTA
  • ROHS