0 Shopping Cart

General Cable/Carol Brand C2103A.21.0605

Part Number:

C2103A.21.0605

Manufacturer:

General Cable/Carol Brand

Ventron No:

169271-C2103A.21.0605

Description:

HOOK-UP 18AWG GRN/YEL 1000'

ECAD Model:

Datasheet:

C2103A.21.0605

Payment:

Payment

Delivery:

Delivery

Quick Request Quote

Please send RFQ , We will respond immediately.

Part Number
Quantity
Company
E-mail
Phone
Comments
  • One Stop Service

    One Stop Service

  • Competitive Price

    Competitive Price

  • Source Traceability

    Source Traceability

  • Same Day Delivery

    Same Day Delivery

Specifications

General Cable/Carol Brand C2103A.21.0605 technical specifications, attributes, parameters and parts with similar specifications to General Cable/Carol Brand C2103A.21.0605.

  • Insulation Material
    PVC
  • Conductor Material
    Copper, Annealed Tinned
  • Jacket (Insulation) Material
    Poly-Vinyl Chloride (PVC)
  • Operating Temperature

    Operating Temperature is the range of temperatures at which an electronic component can function properly. It is typically specified in degrees Celsius (°C) and indicates the minimum and maximum temperatures at which the component can operate without experiencing damage or degradation. Operating Temperature is an important parameter to consider when designing electronic circuits, as it ensures that the components will function reliably in the intended operating environment.

    -20°C~105°C
  • Series

    Series, in the context of electronic components, refers to the arrangement of components in a circuit. When components are connected in series, they form a single path for current to flow through. The total resistance of a series circuit is the sum of the individual resistances of each component. Series connections are often used to control the flow of current in a circuit, as the total resistance can be adjusted by changing the number or type of components in the series.

    2103A
  • Part Status

    Part Status is an electronic component parameter that indicates the availability and production status of a component. It is typically used to inform customers about the availability of a component, whether it is in production, end-of-life, or obsolete. Part Status can also provide information about any restrictions or limitations on the component's use, such as whether it is only available for certain applications or if it has been discontinued.

    Active
  • Moisture Sensitivity Level (MSL)

    Moisture Sensitivity Level (MSL) is a measure of the susceptibility of a surface mount electronic component to moisture-induced damage during soldering. It is classified into six levels, from 1 (least sensitive) to 6 (most sensitive). MSL is determined by the materials used in the component's construction, including the solderability of its terminals and the presence of moisture-absorbing materials. Components with higher MSL ratings require more stringent handling and storage conditions to prevent moisture absorption and subsequent damage during soldering.

    1 (Unlimited)
  • Max Operating Temperature
    105°C
  • Min Operating Temperature
    -20°C
  • Color
    Green, Yellow
  • Wire Gauge

    Wire gauge is a measure of the thickness of a wire. It is typically expressed in American Wire Gauge (AWG), which is a logarithmic scale where a higher number indicates a thinner wire. The larger the wire gauge, the smaller the diameter of the wire. Wire gauge is important because it affects the current-carrying capacity and resistance of a wire. A thicker wire can carry more current and has less resistance than a thinner wire.

    18 AWG
  • Voltage
    600V
  • Cable Type
    Hook-Up
  • Wire/Cable Type
    Hook-Up
  • Wire/Cable Gauge
    18 AWG
  • Jacket Color
    Green, Yellow
  • Conductor Strand
    16/30
  • Jacket (Insulation) Diameter
    0.112 (2.84mm)
  • Insulation Diameter
    2.8448 mm
  • Length

    Length, in the context of electronic components, refers to the physical dimension of a component along its longest axis. It is typically measured in millimeters (mm) or inches (in). Length is a crucial parameter for determining the physical size and space requirements of a component on a printed circuit board (PCB) or other assembly. It also affects the component's electrical characteristics, such as inductance and capacitance, which can be influenced by the length of conductors or traces within the component.

    1000.0' 304.8m
  • Jacket (Insulation) Thickness
    0.032 0.81mm
  • Insulation Thickness
    812.8μm
  • RoHS Status
    RoHS Compliant
  • Ratings
    UL Style 1015, ASTM B-33

Description

C2103A.21.0605 Overview
This product is manufactured by General Cable/Carol Brand and belongs to the category of Single Conductor Cables (Hook-Up Wire). The images we provide are for reference only, for detailed product information please see specification sheet C2103A.21.0605 or the datasheet in PDF format. As a professional electronic components distributor, Ventron has five million electronic components available. Additionally, we have over 500,000 electronic components in stock ready for immediate shipment. If you have requirements, you can send us a quotation form to get the price of C2103A.21.0605. We attach great importance to our customers' purchasing experience and are willing to establish a long-term cooperative relationship with you. If you have any questions or requirements, please feel free to contact us.
C2103A.21.0605 More Descriptions
1C/18 Str Hook Up Grn/Yel

Product Comparison

The three parts on the right have similar specifications to C2103A.21.0605.
  • Image
    Part Number
    Manufacturer
    Insulation Material
    Conductor Material
    Jacket (Insulation) Material
    Operating Temperature
    Series
    Part Status
    Moisture Sensitivity Level (MSL)
    Max Operating Temperature
    Min Operating Temperature
    Color
    Wire Gauge
    Voltage
    Cable Type
    Wire/Cable Type
    Wire/Cable Gauge
    Jacket Color
    Conductor Strand
    Jacket (Insulation) Diameter
    Insulation Diameter
    Length
    Jacket (Insulation) Thickness
    Insulation Thickness
    RoHS Status
    Ratings
    Factory Lead Time
    Mount
    Packaging
    Voltage - Rated
    Voltage - Rated DC
    Outside Diameter
    Package / Case
    Voltage - Rated AC
    Approval Agency
    REACH SVHC
    View Compare
  • C2103A.21.0605
    C2103A.21.0605
    PVC
    Copper, Annealed Tinned
    Poly-Vinyl Chloride (PVC)
    -20°C~105°C
    2103A
    Active
    1 (Unlimited)
    105°C
    -20°C
    Green, Yellow
    18 AWG
    600V
    Hook-Up
    Hook-Up
    18 AWG
    Green, Yellow
    16/30
    0.112 (2.84mm)
    2.8448 mm
    1000.0' 304.8m
    0.032 0.81mm
    812.8μm
    RoHS Compliant
    UL Style 1015, ASTM B-33
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
  • C2103A.12.08
    PVC
    Copper, Annealed Tinned
    Poly-Vinyl Chloride (PVC)
    -30°C~105°C
    2103A
    Active
    -
    -
    -
    -
    18 AWG
    -
    Hook-Up
    -
    18 AWG
    Brown
    16/30
    0.112 (2.84mm)
    -
    100.0' 30.5m
    0.032 0.81mm
    -
    RoHS Compliant
    UL Style 1015, ASTM B-33
    6 Weeks
    Cable
    Spool
    600V
    600V
    2.845 mm
    -
    -
    -
    -
  • C2104A.12.08
    PVC
    Copper, Annealed Tinned
    Poly-Vinyl Chloride (PVC)
    -20°C~105°C
    2104A
    Active
    1 (Unlimited)
    105°C
    -20°C
    Brown
    16 AWG
    600V
    Hook-Up
    Hook-Up
    16 AWG
    Brown
    26/30
    0.124 (3.15mm)
    3.1496 mm
    100.0' 30.5m
    0.032 0.81mm
    812.8μm
    RoHS Compliant
    UL Style 1015, ASTM B-33
    -
    Cable
    -
    600V
    600V
    3.15 mm
    100
    600V
    UL
    Unknown
  • C2107A.12.01
    PVC
    Copper, Annealed Tinned
    Poly-Vinyl Chloride (PVC)
    -20°C~105°C
    2107A
    Active
    1 (Unlimited)
    105°C
    -20°C
    Black
    10 AWG
    600V
    Hook-Up
    Hook-Up
    10 AWG
    Black
    105/30
    0.184 (4.67mm)
    4.6736 mm
    100.0' 30.5m
    0.032 0.81mm
    812.8μm
    RoHS Compliant
    UL Style 1015, ASTM B-33
    -
    -
    -
    -
    -
    -
    100
    -
    -
    -

Certification

  • ISO 9001
  • ISO 13485
  • ISO 45001
  • ASA
  • ESD
  • DUNS
  • SMTA
  • ROHS

Latest News

  • 10 October 2024
    CR2430 vs CR2450 Are They Truly Interchangeable?
      Understanding CR2430 and CR2450 Batteries Comparing the Specifications of CR2430 and CR2450 Comparing the Size and Capacity of CR2430 and CR2450 Comparing the Applications of CR2430 and CR2450 Equivalents of CR2430 and...
  • 10 October 2024
    Discover the Uses of CR123A Batteries
      Understanding CR123A Batteries Common Applications of CR123A Batteries Advantages of Using CR123A Batteries Where Can You Buy CR123A Batteries? Considerations When Choosing CR123A Batteries Recommendations and Best Practices Frequently Asked Questions     In today’s tech-driven world,...
  • 11 October 2024
    Decoding Resistor Values with a Color Code Calculator
      Understanding Resistor Color Codes How Does the Resistor Color Code Calculator Work? Applications of Resistor Color Codes Tips for Decoding Resistor Values Frequently Asked Questions       Resistor plays a crucial role in electronics, controlling...
  • 11 October 2024
    MAP Sensor Location, Symptoms and Cleaning
      MAP Sensor Description MAP Sensor Location Types of MAP Sensors MAP Sensor Symptoms Checking the MAP Sensor MAP Sensor Cleaning Frequently Asked Questions   A MAP Sensor is important for your car's performance. It checks air...