Honeywell Sensing and Productivity Solutions AWM5104VN
- Part Number:
- AWM5104VN
- Manufacturer:
- Honeywell Sensing and Productivity Solutions
- Ventron No:
- 4422330-AWM5104VN
- Description:
- SENSOR AIRFLOW AMP 0-20 SLPM
- Datasheet:
- AWM5104VN
Honeywell Sensing and Productivity Solutions AWM5104VN technical specifications, attributes, parameters and parts with similar specifications to Honeywell Sensing and Productivity Solutions AWM5104VN.
- Factory Lead Time10 Weeks
- MountScrew
- Number of Pins3
- Weight60g
- Material - BodySilicon
- Operating Temperature-20°C~70°C TA
- PackagingBulk
- Published1996
- SeriesAWM5000
- Part StatusActive
- Moisture Sensitivity Level (MSL)1 (Unlimited)
- TerminationConnector
- Reach Compliance Codeunknown
- Output Voltage5V
- Operating Supply Voltage10V
- Max Supply Voltage15V
- Min Supply Voltage8V
- Voltage - Input8V~15V
- Number of Ports2
- Accuracy0.5 %
- Max Output Voltage5V
- Response Time60 ms
- Port StyleThreaded
- Port SizeMale 1/4 0.25 6.35mm NPT
- Power Consumption100mW
- Max Supply Voltage (DC)15V
- Min Supply Voltage (DC)8V
- Max Pressure50 PSI
- Sensing Range0 ~ 20 SLPM
- Flow Sensor TypeAir
- Width32mm
- REACH SVHCNo SVHC
- RoHS StatusRoHS Compliant
- Lead FreeLead Free
Images are for reference only.See Product Specifications for product details.If you are interested to buy Electro Corp (Honeywell Sensing and Productivity Solutions) AWM5104VN.
AWM5104VN More Descriptions
HONEYWELL S&C AWM5104VNMass Air Flow Sensor, Microbridge, 20 l/min, 50 psi, 8 V, 15 V, Threaded
Sensor, Airflow, Signal Conditioning, Unamplified, Threaded Port Style
Flow Sensors MASS AIRFLOW 20L/MIN Threaded 1/4 NPT
Mass Airflow Sensor; Port Style:Threaded; Mounting Type:Screw; No. of Ports:2; Output Voltage Max:5V; Range:0 to 20 SLPM; Sensor Output:Voltage ;RoHS Compliant: Yes
In-Line Flow MeasurementAWM5000 Series Microbridge Mass Airflow Sensors feature a Venturi type flow housing. They measure flow as high as 20 standard liters per minute (SLPM) while inducing a maximum pressure drop of 2.25" H2
Device Type = High Flow Mass Airflow / Amplified Sensor / Media Type = Gas / Flow Rate Max. L/min = 20 / Operating Pressure Max. psi = 50 / Connection Type = 1/4" NPT / Operating Voltage Min. - DC V = 8 / Operating Voltage Max. V = 15 / Operating Temperature Min. °C = -20 / Operating Temperature Max. °C = 70 / Length mm = 162.8 / Height mm = 35.6 / Width mm = 32.3
SENSOR, MASS AIR FLOW, 20L/MIN; Pressure Max:50psi; Supply Voltage Range DC:8V to 15V; Port Style:1/4NPT; SVHC:No SVHC (20-Jun-2011); External Depth:35mm; External Length / Height:163mm; External Width:32mm; Fixing Centres LxW:43.2 x 20.3; Flow Rate Max:20l/min; Hysteresis:± 0.5% of reading; Hysteresis:0.5%; Measuring Range:0 to 20 litres/min; Operating Temperature Max:85°C; Operating Temperature Min:-25°C; Output Voltage:5V; Response Time:60ms; Series:AWM5000; Supply Voltage:10VDC; Supply Voltage DC Max:15V
AWM5000 Series airflow sensor, amplified, flow/pressure range: 0 SLPM to 20.0 SLPM; threaded port style, ¼ NPT In-Line Flow Measurement AWM5000 Series Microbridge Mass Airflow Sensors feature a Venturi type flow housing. They measure flow as high as 20 standard liters per minute (SLPM) while inducing a maximum pressure drop of 2.25" H2O. The microbridge chip is in direct contact with the flow stream, greatly reducing error possibilities due to orifice or bypass channel clogging. Rugged, Versatile Package The rugged plastic package has been designed to withstand common mode pressures up to 50 psi, and the small sensing element allows 100 g of shock without compromising performance. The included "AMP" compatible connector provides reliable connection in demanding applications. On-board Signal Conditioning Each AWM5000 sensor contains circuitry which performs amplification, linearization, temperature compensation, and gas calibration. A 1 to 5 Vdc linear output is possible for all listings regardless of flow range (5, 10, 15, or 20 SLPM) or calibration gas (nitrogen, carbon dioxide, nitrous oxide, or argon). All calibration is performed by active laser CAUTION PRODUCT DAMAGE AWM Series Microbridge Mass Airflow Sensors are not designed to sense liquid flow and will be damaged by liquid flow through the sensor. Failure to comply with these instructions could result in product damage.
Sensor, Airflow, Signal Conditioning, Unamplified, Threaded Port Style
Flow Sensors MASS AIRFLOW 20L/MIN Threaded 1/4 NPT
Mass Airflow Sensor; Port Style:Threaded; Mounting Type:Screw; No. of Ports:2; Output Voltage Max:5V; Range:0 to 20 SLPM; Sensor Output:Voltage ;RoHS Compliant: Yes
In-Line Flow MeasurementAWM5000 Series Microbridge Mass Airflow Sensors feature a Venturi type flow housing. They measure flow as high as 20 standard liters per minute (SLPM) while inducing a maximum pressure drop of 2.25" H2
Device Type = High Flow Mass Airflow / Amplified Sensor / Media Type = Gas / Flow Rate Max. L/min = 20 / Operating Pressure Max. psi = 50 / Connection Type = 1/4" NPT / Operating Voltage Min. - DC V = 8 / Operating Voltage Max. V = 15 / Operating Temperature Min. °C = -20 / Operating Temperature Max. °C = 70 / Length mm = 162.8 / Height mm = 35.6 / Width mm = 32.3
SENSOR, MASS AIR FLOW, 20L/MIN; Pressure Max:50psi; Supply Voltage Range DC:8V to 15V; Port Style:1/4NPT; SVHC:No SVHC (20-Jun-2011); External Depth:35mm; External Length / Height:163mm; External Width:32mm; Fixing Centres LxW:43.2 x 20.3; Flow Rate Max:20l/min; Hysteresis:± 0.5% of reading; Hysteresis:0.5%; Measuring Range:0 to 20 litres/min; Operating Temperature Max:85°C; Operating Temperature Min:-25°C; Output Voltage:5V; Response Time:60ms; Series:AWM5000; Supply Voltage:10VDC; Supply Voltage DC Max:15V
AWM5000 Series airflow sensor, amplified, flow/pressure range: 0 SLPM to 20.0 SLPM; threaded port style, ¼ NPT In-Line Flow Measurement AWM5000 Series Microbridge Mass Airflow Sensors feature a Venturi type flow housing. They measure flow as high as 20 standard liters per minute (SLPM) while inducing a maximum pressure drop of 2.25" H2O. The microbridge chip is in direct contact with the flow stream, greatly reducing error possibilities due to orifice or bypass channel clogging. Rugged, Versatile Package The rugged plastic package has been designed to withstand common mode pressures up to 50 psi, and the small sensing element allows 100 g of shock without compromising performance. The included "AMP" compatible connector provides reliable connection in demanding applications. On-board Signal Conditioning Each AWM5000 sensor contains circuitry which performs amplification, linearization, temperature compensation, and gas calibration. A 1 to 5 Vdc linear output is possible for all listings regardless of flow range (5, 10, 15, or 20 SLPM) or calibration gas (nitrogen, carbon dioxide, nitrous oxide, or argon). All calibration is performed by active laser CAUTION PRODUCT DAMAGE AWM Series Microbridge Mass Airflow Sensors are not designed to sense liquid flow and will be damaged by liquid flow through the sensor. Failure to comply with these instructions could result in product damage.
The three parts on the right have similar specifications to AWM5104VN.
-
ImagePart NumberManufacturerFactory Lead TimeMountNumber of PinsWeightMaterial - BodyOperating TemperaturePackagingPublishedSeriesPart StatusMoisture Sensitivity Level (MSL)TerminationReach Compliance CodeOutput VoltageOperating Supply VoltageMax Supply VoltageMin Supply VoltageVoltage - InputNumber of PortsAccuracyMax Output VoltageResponse TimePort StylePort SizePower ConsumptionMax Supply Voltage (DC)Min Supply Voltage (DC)Max PressureSensing RangeFlow Sensor TypeWidthREACH SVHCRoHS StatusLead FreeView Compare
-
AWM5104VN10 WeeksScrew360gSilicon-20°C~70°C TABulk1996AWM5000Active1 (Unlimited)Connectorunknown5V10V15V8V8V~15V20.5 %5V60 msThreadedMale 1/4 0.25 6.35mm NPT100mW15V8V50 PSI0 ~ 20 SLPMAir32mmNo SVHCRoHS CompliantLead Free-
-
10 WeeksScrew360gSilicon-20°C~70°C TABulk1996AWM5000Active1 (Unlimited)Connectorunknown5V10V15V8V8V~15V2-5V60 msThreadedMale 1/4 6.35mm 18 NPT100mW15V8V50 PSI0 ~ 5 SLPMAir32mmNo SVHCRoHS CompliantLead Free
-
15 Weeks-360gSilicon-20°C~70°C TABulk1998AWM5000Active1 (Unlimited)-unknown5V10V15V8V8V~15V-0.5 %5V60 ms-Male 1/4 6.35mm 18 NPT100mW---0 ~ 20 SLPMAir--RoHS Compliant-
-
15 Weeks-360gSilicon-20°C~70°C TABulk1998AWM5000Active1 (Unlimited)-unknown-10V15V8V8V~15V--5V60 ms-Male 1/4 6.35mm 18 NPT100mW---0 ~ 15 SLPMAir--RoHS Compliant-
Popular Search Part Number
Related Keywords
Search Tags
Latest News
-
13 September 2023
The Difference Between CR2016 and CR2032 Button Batteries
Although CR2032 and CR2016 batteries are common coin-type batteries with similar appearance and the same voltage, they have obvious differences in power capacity and size. Below we will... -
14 September 2023
L7809CV Pin Connection, Technical Parameters and Features
Ⅰ. What is L7809CV?L7809CV is a linear voltage regulator with a fixed output voltage and is a type of three-terminal voltage regulator. It uses a series voltage stabilizing... -
14 September 2023
TDA7297 VS TDA7266: What Is The Difference?
In audio equipment, the power amplifier is one of the crucial components. It can amplify low-voltage, low-current signals into high-voltage, high-current signals, thereby increasing output power. Among them,... -
15 September 2023
ATMEGA2560-16AU Footprint, Parameters and Application
Ⅰ. What is ATMEGA2560-16AU?ATMEGA2560-16AU is a powerful MCU microcontroller produced by Microchip Corporation of the United States. It uses the AVR CPU core, combined with a rich instruction...
Help you to save your cost and time.
Reliable package for your goods.
Fast Reliable Delivery to save time.
Quality premium after-sale service.