0 Shopping Cart

Weidmuller 1958480000

Part Number:

1958480000

Manufacturer:

Weidmuller

Ventron No:

1934801-1958480000

Description:

TERM BLOCK PLUG 16POS 90DEG 5MM

ECAD Model:

Datasheet:

1958480000

Payment:

Payment

Delivery:

Delivery

Quick Request Quote

Please send RFQ , We will respond immediately.

Part Number
Quantity
Company
E-mail
Phone
Comments
  • One Stop Service

    One Stop Service

  • Competitive Price

    Competitive Price

  • Source Traceability

    Source Traceability

  • Same Day Delivery

    Same Day Delivery

Specifications

Weidmuller 1958480000 technical specifications, attributes, parameters and parts with similar specifications to Weidmuller 1958480000.

  • Factory Lead Time
    12 Weeks
  • Contact Material

    Contact Material refers to the material used to make the electrical contacts in a component. It determines the electrical conductivity, durability, and resistance to corrosion and wear of the contacts. Common contact materials include copper, silver, gold, and alloys of these metals. The choice of contact material depends on the specific application and the required performance characteristics.

    Copper Alloy
  • Mount
    Free Hanging
  • Mounting Type

    Mounting Type refers to the method by which an electronic component is attached to a printed circuit board (PCB) or other surface. Common mounting types include: * Through-hole: Component leads are inserted into holes in the PCB and soldered on the other side. * Surface-mount: Component is placed on the surface of the PCB and soldered in place. * Press-fit: Component is pressed into place on the PCB without soldering. * Socket: Component is inserted into a socket on the PCB, allowing for easy replacement. The mounting type is determined by factors such as the component's size, shape, and power requirements.

    Free Hanging (In-Line)
  • Housing Material

    Housing Material refers to the material used to construct the outer casing or enclosure of an electronic component.

    Polybutylene Terephthalate (PBT)
  • Operating Temperature

    Operating Temperature is the range of temperatures at which an electronic component can function properly. It is typically specified in degrees Celsius (°C) and indicates the minimum and maximum temperatures at which the component can operate without experiencing damage or degradation. Operating Temperature is an important parameter to consider when designing electronic circuits, as it ensures that the components will function reliably in the intended operating environment.

    -50°C~100°C
  • Packaging
    Bulk
  • Series

    Series, in the context of electronic components, refers to the arrangement of components in a circuit. When components are connected in series, they form a single path for current to flow through. The total resistance of a series circuit is the sum of the individual resistances of each component. Series connections are often used to control the flow of current in a circuit, as the total resistance can be adjusted by changing the number or type of components in the series.

    Omnimate BL
  • Published
    2010
  • Feature
    Retention Latches (Wire Side)
  • Part Status

    Part Status is an electronic component parameter that indicates the availability and production status of a component. It is typically used to inform customers about the availability of a component, whether it is in production, end-of-life, or obsolete. Part Status can also provide information about any restrictions or limitations on the component's use, such as whether it is only available for certain applications or if it has been discontinued.

    Active
  • Moisture Sensitivity Level (MSL)

    Moisture Sensitivity Level (MSL) is a measure of the susceptibility of a surface mount electronic component to moisture-induced damage during soldering. It is classified into six levels, from 1 (least sensitive) to 6 (most sensitive). MSL is determined by the materials used in the component's construction, including the solderability of its terminals and the presence of moisture-absorbing materials. Components with higher MSL ratings require more stringent handling and storage conditions to prevent moisture absorption and subsequent damage during soldering.

    1 (Unlimited)
  • Termination

    Termination refers to the electrical characteristics of a component or circuit at its input or output terminals. It describes how the component or circuit interacts with external signals or devices. Termination can involve matching impedance, providing voltage or current regulation, or filtering unwanted signals. Proper termination ensures efficient signal transfer, minimizes reflections, and prevents damage to components. It is crucial for maintaining signal integrity and optimizing circuit performance.

    Screw
  • ECCN Code
    EAR99
  • Connector Type

    Connector Type refers to the physical interface used to connect an electronic component to other devices or systems. It specifies the shape, size, pin configuration, and mating mechanism of the connector. Common connector types include USB, HDMI, Ethernet, and power connectors. The choice of connector type depends on factors such as signal type, data rate, power requirements, and environmental conditions.

    Terminal Block
  • Color
    Black
  • Number of Rows
    1
  • Voltage - Rated

    Voltage - Rated refers to the maximum voltage that an electronic component can withstand without being damaged. It is typically specified in volts (V) and is an important parameter to consider when selecting components for a circuit. Exceeding the rated voltage can lead to component failure, so it is important to ensure that the voltage applied to a component does not exceed its rated voltage.

    300V
  • Additional Feature
    STANDARD: UL 94V-0
  • HTS Code
    8536.69.40.40
  • Pitch

    Pitch, in the context of electronic components, refers to the distance between the centers of adjacent pins or terminals on a component. It is typically measured in millimeters (mm) or inches (in). The pitch determines the spacing between components on a printed circuit board (PCB) and affects the overall size and layout of the board. A smaller pitch allows for more components to be placed on a given area, but it also increases the risk of shorts and other manufacturing defects.

    0.197 5.00mm
  • Insulation Height
    0.555 14.10mm
  • Current Rating

    Current Rating is the maximum amount of current that an electronic component can safely handle without overheating or failing. It is typically expressed in amperes (A) or milliamperes (mA). Exceeding the current rating can damage the component and potentially create a safety hazard. The current rating is determined by the physical characteristics of the component, such as its size, material, and construction.

    13A
  • Termination Style

    Termination Style refers to the method used to connect an electronic component to a circuit board or other components. It describes the physical form and electrical characteristics of the connection point. Common termination styles include through-hole, surface mount, and press-fit. Through-hole components have leads that are inserted into holes on the circuit board and soldered in place. Surface mount components are soldered directly onto the surface of the circuit board. Press-fit components are inserted into holes on the circuit board and held in place by friction.

    Screw - Clamping Yoke (Tension Sleeve)
  • Approval Agency
    CSA, UR
  • Voltage
    300V
  • Number of Levels
    1
  • Current
    10A
  • Wire Gauge (Max)
    26 AWG
  • Wire Gauge (Min)
    12 AWG
  • Wire/Cable Gauge
    12 AWG
  • Number of Poles

    The number of poles in an electronic component, such as an inductor or capacitor, refers to the number of pairs of magnetic or electric field lines that pass through the component's core. A higher number of poles generally indicates a stronger magnetic or electric field and, consequently, a higher inductance or capacitance. The number of poles is a crucial parameter in determining the component's performance and suitability for specific applications.

    16
  • Contact Mating Finish
    Tin
  • Number of Decks
    1
  • Wire Gauge or Range - AWG

    Wire Gauge or Range - AWG (American Wire Gauge) is a standardized system for measuring the diameter of electrical wire. It is used to determine the current-carrying capacity and resistance of a wire. The higher the AWG number, the smaller the wire diameter and the lower the current-carrying capacity. AWG is commonly used in electrical wiring, electronics, and telecommunications.

    12-30 AWG
  • Current - UL

    Current - Ul is an electronic component parameter that specifies the maximum leakage current that can flow through the component when it is reverse-biased. It is typically measured in microamperes (µA) or nanoamperes (nA). A low Current - Ul value indicates that the component has a high resistance to leakage current, which is desirable in many applications.

    20A
  • Voltage - IEC
    400V
  • Torque - Screw
    0.4-0.5 Nm (3.5-4.4 Lb-In)
  • Number of Ways
    16
  • Safety Approval
    UL; CSA
  • Plug Wire Entry
    90°
  • Wire Gauge or Range - mm²
    0.2-4mm2
  • Current - IEC
    23A
  • Screw Size
    M2.5
  • Stripping Length
    7mm
  • Wire Cross Section
    4 mm2
  • Material Flammability Rating
    UL94 V-0
  • REACH SVHC
    Unknown
  • RoHS Status
    RoHS Compliant
  • Flammability Rating
    UL94 V-0

Description

1958480000 Overview
A Terminal Block package is included with it.Its mounting type is Free Hanging (In-Line).Packaging is performed using a Bulk case.It is part of the Omnimate BL Series of products.Additionally, there are other features, such as STANDARD: UL 94V-0.A number of features make it more powerful because of its Retention Latches (Wire Side) feature.Free Hanging mounts the part.There is no operating temperature for the device.Several of the benefits of this part are also shared by other Plug, Female Sockets products.

1958480000 Features
Omnimate BL series


1958480000 Applications
There are a lot of Weidmüller
1958480000 Terminal Blocks applications.


Datacom
Communication
Medical technology
Military Technology
Measuring & Control Technology
Instrumentation
Automotive Electronics
Telecommunications
Data Technology
Blowers
1958480000 More Descriptions
Pluggable Terminal Block Plug 16 Position 5mm Right Angle Cable Mount Black Box
TERMINAL BLOCK PLUGGABLE 16POS, 26-12AWG; Connector Type:Pluggable Terminal Block; Series:BLZP; Connector Mounting:Cable; Pitch Spacing:5mm; No. of Contacts:16; Wire Size (AWG):26-12; Contact Plating:Tin
BLZP 5.00/16/90 SN BK BX. PCB plug-in connector, female plug, 5.00 mm, No. of poles: 16, 90°, Clamping yoke connection, Clamping range, rated connection, max.: 4 mm², Box GTIN (EAN): 4032248637256
Terminal Block Pluggable 16 Position, 26-12Awg; Pitch Spacing:5Mm; No. Of Positions:16Positions; Wire Size Awg Min:30Awg; Wire Size Awg Max:12Awg; Conductor Area Csa:4Mm²; Wire Connection Method:Screw; Rated Current:15.5A Rohs Compliant: Yes |Weidmuller 1958480000

Certification

  • ISO 9001
  • ISO 13485
  • ISO 45001
  • ASA
  • ESD
  • DUNS
  • SMTA
  • ROHS

Latest News

  • 08 March 2024
    In-depth Analysis of SS34 Schottky Diode
    Ⅰ. Overview of SS34Ⅱ. Purpose of SS34 diodeⅢ. Technical parameters of SS34 diodeⅣ. Advantages of SS34 diodesⅤ. Working principle of SS34 diodeⅥ. Typical characteristics of SS34 diodesⅦ. Case...
  • 11 March 2024
    BTS50085-1TMA Specifications, Functions, Purpose and More
    Ⅰ. What is BTS50085-1TMA?Ⅱ. Specifications of BTS50085-1TMAⅢ. What are the functions of BTS50085-1TMA?Ⅳ. Inverse load current operation of BTS50085-1TMAⅤ. Externally adjustable current limit of BTS50085-1TMAⅥ. How to use...
  • 11 March 2024
    LM317: Ideal for Adjustable, High-Efficiency Three-Terminal Regulators
    Ⅰ. Introduction to LM317Ⅱ. The function of LM317 adjustable voltage stabilized power supply voltage stabilizing circuitⅢ. Soft-start circuit of LM317Ⅳ. Minimum stable operating current of LM317Ⅴ. Calculation of...
  • 12 March 2024
    MPU-6050 Manufacturer, Working Principle, Application and Package
    Ⅰ. Introduction to MPU-6050Ⅱ. Manufacturer of MPU-6050Ⅲ. Internal block diagram of MPU-6050Ⅳ. How does the MPU-6050 work?Ⅴ. Where is MPU-6050 used?Ⅵ. Package of MPU-6050Ⅶ. How to reduce the...